Where Used List (Function Module) for SAP ABAP Table/Structure Field OIU_PR_WC-WL_NO (OIU_PR_WC)
SAP ABAP Table/Structure Field
OIU_PR_WC - WL_NO (OIU_PR_WC) is used by
# | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
||
1 | ![]() |
BAPI_OIU_RFSH_WC_HDR VALUE(WL_NO) LIKE OIU_PR_WC-WL_NO
|
Refresh PREMAS Well Completion Data | ![]() |
![]() |
![]() |
2 | ![]() |
BAPI_OIU_RFSH_WC_HDR
|
Refresh PREMAS Well Completion Data | ![]() |
![]() |
![]() |
3 | ![]() |
BAPI_OIU_RFSH_WC_MASTER VALUE(WL_NO) LIKE OIU_PR_WC-WL_NO
|
Refresh PREMAS For All WC Data - 11 IDOC Processes | ![]() |
![]() |
![]() |
4 | ![]() |
BAPI_OIU_RFSH_WC_MASTER
|
Refresh PREMAS For All WC Data - 11 IDOC Processes | ![]() |
![]() |
![]() |
5 | ![]() |
BAPI_WELLCOMP_CHANGE
|
Changes a Well Completion Record | ![]() |
![]() |
![]() |
6 | ![]() |
BAPI_WELLCOMP_CREATE
|
Creates a Well Completion Record | ![]() |
![]() |
![]() |
7 | ![]() |
DEQUEUE_E_OIU_WC VALUE(WL_NO) TYPE OIU_PR_WC-WL_NO OPTIONAL
|
Release lock on object E_OIU_WC | ![]() |
![]() |
|
8 | ![]() |
ENQUEUE_E_OIU_WC VALUE(WL_NO) TYPE OIU_PR_WC-WL_NO OPTIONAL
|
Request lock for object E_OIU_WC | ![]() |
![]() |
|
9 | ![]() |
OIUCA_DOI_MP_WC_DETAIL_READ
|
Reading OIU_SB_DOIWC and OIU_SB_DOIMP tables | ![]() |
![]() |
![]() |
10 | ![]() |
OIUCA_PRP_DETAIL_READ
|
Reading prph and prpd tables | ![]() |
![]() |
![]() |
11 | ![]() |
OIUCA_READ_DOIMP_DOIWC_TABLES
|
read the tables OIU_SB_DOIWC and OIU_SB_DOIMP | ![]() |
![]() |
![]() |
12 | ![]() |
OIUCA_READ_PRPH_TABLE
|
read the table oiuca_prph | ![]() |
![]() |
![]() |
13 | ![]() |
OIUGT_DN_MAINTAIN_NODES
|
Delivery Network - maintain nodes | ![]() |
![]() |
![]() |
14 | ![]() |
OIUGT_DN_MAINTAIN_NODES VALUE(WL_NO) TYPE OIU_PR_WC-WL_NO OPTIONAL
|
Delivery Network - maintain nodes | ![]() |
![]() |
![]() |
15 | ![]() |
OIUH_DSPRTSANDBYFLNOWRAP
|
OIUH_DSPRTSANDBYFLNOWRAP | ![]() |
![]() |
![]() |
16 | ![]() |
OIUPC_AVGHWC_READ
|
Availability Grouping Header (Well Completion | ![]() |
![]() |
![]() |
17 | ![]() |
OIUPC_AVGH_READ
|
Availability Grouping Header - No WC, MP/only DN | ![]() |
![]() |
![]() |
18 | ![]() |
OIUPC_AVGMP_DETAIL_READ
|
Availability Grouping(Measurement Point) Detail Read | ![]() |
![]() |
![]() |
19 | ![]() |
OIUPC_AVGWC_DETAIL_READ
|
Availability Grouping Detail - Well Completion | ![]() |
![]() |
![]() |
20 | ![]() |
OIUPR_GET1_WCALF REFERENCE(I_WL_NO) LIKE OIU_PR_WC-WL_NO
|
Display WL/WC allocation factors | ![]() |
![]() |
![]() |
21 | ![]() |
OIUPR_GET1_WCALF
|
Display WL/WC allocation factors | ![]() |
![]() |
![]() |
22 | ![]() |
OIUREP_FG1_SELECT_WC_DATA
|
Select Well Completion Data | ![]() |
![]() |
![]() |
23 | ![]() |
OIUREP_FG1_SELECT_WC_DATA REFERENCE(I_WL_NO) TYPE OIU_PR_WC-WL_NO
|
Select Well Completion Data | ![]() |
![]() |
![]() |
24 | ![]() |
OIUREP_WC_PPA_DELETE_PAR_CHILD VALUE(WL_NO) LIKE OIU_PR_WC-WL_NO
|
Deletes from parent Well Completion PPA table and its child tables | ![]() |
![]() |
![]() |
25 | ![]() |
OIUREP_WC_PPA_DELETE_PAR_CHILD
|
Deletes from parent Well Completion PPA table and its child tables | ![]() |
![]() |
![]() |
26 | ![]() |
OIUVL_READ_TTRD_DATA
|
Reads table OIUVL_TTRD | ![]() |
![]() |
![]() |
27 | ![]() |
OIUX1_PROCESS_TAX
|
Processes tax data to a PUID/lease level | ![]() |
![]() |
![]() |
28 | ![]() |
OIUX1_PROCESS_TAXF
|
Processes tax data to a PUID/lease level | ![]() |
![]() |
![]() |
29 | ![]() |
OIUX1_WY_20023002_DOWNLOAD
|
Smartform driver for WY form 2000 3000 | ![]() |
![]() |
![]() |
30 | ![]() |
OIUX1_WY_20023002_PDF
|
form driver for WY form 2002 3002 | ![]() |
![]() |
![]() |
31 | ![]() |
OIUX1_WY_20023002_SMARTFORM
|
Smartform driver for WY form 2000 3000 | ![]() |
![]() |
![]() |
32 | ![]() |
OIU_3D_GET_NEXT_NODE
|
Get next node up/down stream | ![]() |
![]() |
![]() |
33 | ![]() |
OIU_3D_GET_PREV_NODE
|
Get the previous node | ![]() |
![]() |
![]() |
34 | ![]() |
OIU_3D_GET_PREV_NODE REFERENCE(E_WL) LIKE OIU_PR_WC-WL_NO
|
Get the previous node | ![]() |
![]() |
![]() |
35 | ![]() |
OIU_CAP_WC_ROLL
|
Capacity Roll - Well Completion | ![]() |
![]() |
![]() |
36 | ![]() |
OIU_CHECK_DOWNHOLE_COMMINGLED VALUE(I_WL_NO) LIKE OIU_PR_WC-WL_NO
|
Check WL/WC is not a child downhole commingled WL/WC | ![]() |
![]() |
![]() |
37 | ![]() |
OIU_CHECK_DOWNHOLE_COMMINGLED REFERENCE(E_PARENT_WL_NO) LIKE OIU_PR_WC-WL_NO
|
Check WL/WC is not a child downhole commingled WL/WC | ![]() |
![]() |
![]() |
38 | ![]() |
OIU_CHECK_DOWNHOLE_COMMINGLED
|
Check WL/WC is not a child downhole commingled WL/WC | ![]() |
![]() |
![]() |
39 | ![]() |
OIU_DN_GET_MPS_DWNSTRM_SPLT
|
Get MP's downstream of a split | ![]() |
![]() |
![]() |
40 | ![]() |
OIU_DN_GET_MPS_DWNSTRM_SPLT REFERENCE(I_WL) LIKE OIU_PR_WC-WL_NO OPTIONAL
|
Get MP's downstream of a split | ![]() |
![]() |
![]() |
41 | ![]() |
OIU_DN_GET_NEXT_NODE_DWNSTRM
|
Get next node downstream | ![]() |
![]() |
![]() |
42 | ![]() |
OIU_DN_GET_NEXT_NODE_DWNSTRM REFERENCE(E_WL) LIKE OIU_PR_WC-WL_NO
|
Get next node downstream | ![]() |
![]() |
![]() |
43 | ![]() |
OIU_DN_GET_NEXT_NODE_UPSTRM REFERENCE(E_WL) LIKE OIU_PR_WC-WL_NO
|
Get next node upstream | ![]() |
![]() |
![]() |
44 | ![]() |
OIU_DN_GET_NEXT_NODE_UPSTRM
|
Get next node upstream | ![]() |
![]() |
![]() |
45 | ![]() |
OIU_DN_IS_NEXT_NODE_WC
|
Given a MP is the next node a WC | ![]() |
![]() |
![]() |
46 | ![]() |
OIU_DN_IS_NEXT_NODE_WC REFERENCE(E_WL) LIKE OIU_PR_WC-WL_NO
|
Given a MP is the next node a WC | ![]() |
![]() |
![]() |
47 | ![]() |
OIU_DN_OBJ_FOUND REFERENCE(I_WL) LIKE OIU_PR_WC-WL_NO OPTIONAL
|
Is a MP or WL/WC part of the network | ![]() |
![]() |
![]() |
48 | ![]() |
OIU_DN_OBJ_FOUND
|
Is a MP or WL/WC part of the network | ![]() |
![]() |
![]() |
49 | ![]() |
OIU_DN_SET_STRT_NODE REFERENCE(I_WL) LIKE OIU_PR_WC-WL_NO OPTIONAL
|
Set the starting-point node | ![]() |
![]() |
![]() |
50 | ![]() |
OIU_DN_SET_STRT_NODE
|
Set the starting-point node | ![]() |
![]() |
![]() |
51 | ![]() |
OIU_GET_COMMINGLED_PARENT
|
Well Completion and Commingled Percentages Get | ![]() |
![]() |
![]() |
52 | ![]() |
OIU_GET_WC_MASTER_LIST
|
Retrieve list of master data (delivery networks) for KKHI | ![]() |
![]() |
![]() |
53 | ![]() |
OIU_PPN_MAIN
|
Main call function for the ppn routine | ![]() |
![]() |
![]() |
54 | ![]() |
OIU_PPN_MAIN VALUE(PPN_WL_NO) LIKE OIU_PR_WC-WL_NO OPTIONAL
|
Main call function for the ppn routine | ![]() |
![]() |
![]() |
55 | ![]() |
OIU_PPN_REVENUE_ALT_USE
|
Alternate Use PPN Function | ![]() |
![]() |
![]() |
56 | ![]() |
OIU_PPN_REVENUE_ALT_USE REFERENCE(I_WL_NO) LIKE OIU_PR_WC-WL_NO OPTIONAL
|
Alternate Use PPN Function | ![]() |
![]() |
![]() |
57 | ![]() |
OIU_VALIDATE_NETWORK_STRUCTURE
|
Validates delivery network structure | ![]() |
![]() |
![]() |
58 | ![]() |
OIU_VA_NETWORK_MP_WC_CREATE
|
Create network measurement points and well completions | ![]() |
![]() |
![]() |
59 | ![]() |
OIU_WC_DOWNTIME VALUE(I_WL_NO) LIKE OIU_PR_WC-WL_NO
|
Well Completion Downtime | ![]() |
![]() |
![]() |
60 | ![]() |
OIU_WC_DOWNTIME
|
Well Completion Downtime | ![]() |
![]() |
![]() |
61 | ![]() |
OIU_WC_MASTER_READ
|
Read Well Completion Master Data Record | ![]() |
![]() |
![]() |
62 | ![]() |
OIU_WC_MASTER_READ VALUE(WL_NO) LIKE OIU_PR_WC-WL_NO
|
Read Well Completion Master Data Record | ![]() |
![]() |
![]() |