Table/Structure Field list used by SAP ABAP Program LEG42F04 (Forms for open)
SAP ABAP Program
LEG42F04 (Forms for open) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | DD07V - DDTEXT | Short Text for Fixed Values | ||
| 2 | EADZ - BIS | Date at Which a Time Slice Expires | ||
| 3 | EADZ - LOGIKZW | Logical register number | ||
| 4 | EANL - ANLAGE | Installation | ||
| 5 | EANLKEY - ANLAGE | Installation | ||
| 6 | EANLKEY - MANDT | Client | ||
| 7 | EASTI - BIS | Date at Which a Time Slice Expires | ||
| 8 | EASTI - INDEXNR | Consecutive number of register relationship | ||
| 9 | EASTI - LOGIKZW | Logical register number | ||
| 10 | EASTIH - INDEXNR | Consecutive number of register relationship | ||
| 11 | EASTL - ANLAGE | Installation | ||
| 12 | EASTL - BIS | Date at Which a Time Slice Expires | ||
| 13 | EASTL - LOGIKNR | Logical device number | ||
| 14 | EASTS - ANLAGE | Installation | ||
| 15 | EASTS - BIS | Date at Which a Time Slice Expires | ||
| 16 | EASTS - LOGIKZW | Logical register number | ||
| 17 | EGERR - BIS | Date at Which a Time Slice Expires | ||
| 18 | EGERR - EQUNR | Equipment Number | ||
| 19 | EMSG_GEN - MSGTY | Message type | ||
| 20 | EMSG_MSG - KZ_BREAK | Indicator: Breakpoint | ||
| 21 | EMSG_MSG - KZ_EXC | Indicator: Output EXCEPTION | ||
| 22 | EMSG_MSG - KZ_MSG | Indicator: Output message | ||
| 23 | EMSG_MSG - MSGID | Message Class | ||
| 24 | EMSG_MSG - MSGNO | Message Number | ||
| 25 | EMSG_MSG - MSGTY | Message Type | ||
| 26 | EMSG_MSG - MSGV1 | Message Variable | ||
| 27 | EMSG_MSG - MSGV2 | Message Variable | ||
| 28 | EMSG_MSG - MSGV3 | Message Variable | ||
| 29 | EMSG_MSG - MSGV4 | Message Variable | ||
| 30 | ETDZ - AB | Date from which time slice is valid | ||
| 31 | ETDZ - BIS | Date at Which a Time Slice Expires | ||
| 32 | ETDZ - EQUNR | Equipment Number | ||
| 33 | ETDZ - ZWNUMMER | Register | ||
| 34 | ETYP - BAUFORM | Device category description | ||
| 35 | ETYP - MATNR | Material Number | ||
| 36 | ETYP - MESSART | Type of measurement | ||
| 37 | ETYP - NENNBEL | Nominal load | ||
| 38 | ETYP - ZSPANNP | Register factor: primary transformer voltage | ||
| 39 | ETYP - ZSPANNS | Register factor: secondary transformer voltage | ||
| 40 | ETYP - ZSTROMP | Register factor: primary transformer current | ||
| 41 | ETYP - ZSTROMS | Register factor: secondary transformer current | ||
| 42 | EUILNR - LOGIKNR | Logical device number | ||
| 43 | EUILNR_KEY - LOGIKNR | Logical device number | ||
| 44 | EUILZW - LOGIKZW | Logical register number | ||
| 45 | EUILZW_KEY - LOGIKZW | Logical register number | ||
| 46 | EZUZ - BIS | Date at Which a Time Slice Expires | ||
| 47 | EZUZ - LOGIKNR2 | Logical device number | ||
| 48 | EZUZ - LOGIKZW | Logical register number | ||
| 49 | EZUZ - ZUART | Device allocation type | ||
| 50 | ISU00_OBJ_CONTR - ENQ_DONE | Lock Was Set | ||
| 51 | ISU00_OBJ_CONTR - NO_CHANGE | No change allowed | ||
| 52 | ISU00_OBJ_CONTR - NO_DIALOG | Suppress database update | ||
| 53 | ISU00_OBJ_CONTR - NO_OTHER | No other object permitted | ||
| 54 | ISU00_OBJ_CONTR - UPD_ONLINE | Update online | ||
| 55 | ISU00_OBJ_CONTR - WMODE | Processing mode (1 = display, 2 = change, 3 = create...) | ||
| 56 | ISU07_CUSTOMIZE - EGERR_INT_NUM_ALL | Device Info Record: Automatic Number Allocation Permitted | ||
| 57 | ISU07_CUSTOMIZE - EGERR_INT_NUM_NESS | Device Info Record: Automatic Number Allocation Mandatory | ||
| 58 | ISU07_CUSTOMIZE - TE100 | ISU07_CUSTOMIZE-TE100 | ||
| 59 | ISU07_EGER - AB | Date from which time slice is valid | ||
| 60 | ISU07_EGER - BIS | Date at Which a Time Slice Expires | ||
| 61 | ISU07_EGER - EQUNR | Equipment Number | ||
| 62 | ISU07_EGERKEY - EQUNR | Equipment Number | ||
| 63 | ISU07_EGERKEY - MANDT | Client | ||
| 64 | ISU07_INSTALL_STRUC - IEADZ | ISU07_INSTALL_STRUC-IEADZ | ||
| 65 | ISU07_INSTALL_STRUC - IEASTI | ISU07_INSTALL_STRUC-IEASTI | ||
| 66 | ISU07_INSTALL_STRUC - IEASTIH | ISU07_INSTALL_STRUC-IEASTIH | ||
| 67 | ISU07_INSTALL_STRUC - IEASTL | ISU07_INSTALL_STRUC-IEASTL | ||
| 68 | ISU07_INSTALL_STRUC - IEASTS | ISU07_INSTALL_STRUC-IEASTS | ||
| 69 | ISU07_INSTALL_STRUC - IETDZ | ISU07_INSTALL_STRUC-IETDZ | ||
| 70 | ISU07_INSTALL_STRUC - IEZUZ | ISU07_INSTALL_STRUC-IEZUZ | ||
| 71 | ISU_TIMESL - AB | Date from which time slice is valid | ||
| 72 | ISU_ZWFAKT - ZSPANNP | Register factor: primary transformer voltage | ||
| 73 | ISU_ZWFAKT - ZSPANNS | Register factor: secondary transformer voltage | ||
| 74 | ISU_ZWFAKT - ZSTROMP | Register factor: primary transformer current | ||
| 75 | ISU_ZWFAKT - ZSTROMS | Register factor: secondary transformer current | ||
| 76 | REG42_DEV - AB | Date from which time slice is valid | ||
| 77 | REG42_DEV - ADDRELINE2 | Address line | ||
| 78 | REG42_DEV - BAUFORM | Device category description | ||
| 79 | REG42_DEV - BEZEICHN_PAR | Text (30 Characters) | ||
| 80 | REG42_DEV - BEZEICHN_PLOMBE | Text Field | ||
| 81 | REG42_DEV - BIS | Date at Which a Time Slice Expires | ||
| 82 | REG42_DEV - DEVLOC | Device Location | ||
| 83 | REG42_DEV - EQUNR | Equipment Number | ||
| 84 | REG42_DEV - GERAET | Device | ||
| 85 | REG42_DEV - MANDT | Client | ||
| 86 | REG42_DEV - MATNR | Device category | ||
| 87 | REG42_DEV - MESSART | Type of measurement | ||
| 88 | REG42_DEV - NENNBEL | Nominal load | ||
| 89 | REG42_DEV - NEW_EGERR | Indicators | ||
| 90 | REG42_DEV - PARAMETR | Parametrization | ||
| 91 | REG42_DEV - PLOMBE | Seal code | ||
| 92 | REG42_DEV - PRIMWNR1 | Winding number of active primary winding | ||
| 93 | REG42_DEV - PRIMWNR2 | Winding number of active primary winding | ||
| 94 | REG42_DEV - SEKWNR1 | Winding number of active secondary winding | ||
| 95 | REG42_DEV - SEKWNR2 | Winding number of active secondary winding | ||
| 96 | REG42_DEV - SPARTE | Division | ||
| 97 | REG42_DEV - SPARTYP | Division category | ||
| 98 | REG42_DEV - SPATXT | Name | ||
| 99 | REG42_DEV - TEXT30 | Text (30 Characters) | ||
| 100 | REG42_DEV - TRANSFAKTNEW | Billing factor | ||
| 101 | REG42_DEV - UMBAUGR | Modification reason | ||
| 102 | REG42_DEV - WANDART | Transformer type | ||
| 103 | REG42_DEV - WGRUPPE | Winding group | ||
| 104 | REG42_DEV - ZSPANNP | Register factor: primary transformer voltage | ||
| 105 | REG42_DEV - ZSPANNS | Register factor: secondary transformer voltage | ||
| 106 | REG42_DEV - ZSTROMP | Register factor: primary transformer current | ||
| 107 | REG42_DEV - ZSTROMS | Register factor: secondary transformer current | ||
| 108 | REG42_DEV_INPUT - PARAMETR | Parametrization | ||
| 109 | REG42_DEV_INPUT - PLOMBE | Seal code | ||
| 110 | REG42_DEV_INPUT - PRIMWNR1 | Winding number of active primary winding | ||
| 111 | REG42_DEV_INPUT - PRIMWNR2 | Winding number of active primary winding | ||
| 112 | REG42_DEV_INPUT - SEKWNR1 | Winding number of active secondary winding | ||
| 113 | REG42_DEV_INPUT - SEKWNR2 | Winding number of active secondary winding | ||
| 114 | REG42_DEV_INPUT - UMBAUGR | Modification reason | ||
| 115 | REG42_DEV_INPUT - WGRUPPE | Winding group | ||
| 116 | REG42_DEV_INPUT - ZSPANNP | Register factor: primary transformer voltage | ||
| 117 | REG42_DEV_INPUT - ZSPANNS | Register factor: secondary transformer voltage | ||
| 118 | REG42_DEV_INPUT - ZSTROMP | Register factor: primary transformer current | ||
| 119 | REG42_DEV_INPUT - ZSTROMS | Register factor: secondary transformer current | ||
| 120 | REG42_DEV_INPUT_FLAG - AB | Date from which time slice is valid | ||
| 121 | REG42_DEV_INPUT_FLAG - BIS | Date at Which a Time Slice Expires | ||
| 122 | REG42_DEV_INPUT_FLAG - EQUNR | Equipment Number | ||
| 123 | REG42_DEV_INPUT_FLAG - GERAET | Device | ||
| 124 | REG42_DEV_INPUT_FLAG - MATNR | Device category | ||
| 125 | REG42_DEV_INPUT_FLAG_KEY - AB | Date from which time slice is valid | ||
| 126 | REG42_DEV_INPUT_FLAG_KEY - BIS | Date at Which a Time Slice Expires | ||
| 127 | REG42_DEV_INPUT_FLAG_KEY - EQUNR | Equipment Number | ||
| 128 | REG42_DEV_INPUT_FLAG_KEY - GERAET | Device | ||
| 129 | REG42_DEV_INPUT_FLAG_KEY - MATNR | Device category | ||
| 130 | REG42_DEV_INPUT_LAST_TIMSLICE - PRIMWNR1 | Winding number of active primary winding | ||
| 131 | REG42_DEV_INPUT_LAST_TIMSLICE - PRIMWNR2 | Winding number of active primary winding | ||
| 132 | REG42_DEV_INPUT_LAST_TIMSLICE - SEKWNR1 | Winding number of active secondary winding | ||
| 133 | REG42_DEV_INPUT_LAST_TIMSLICE - SEKWNR2 | Winding number of active secondary winding | ||
| 134 | REG42_DEV_INPUT_LAST_TIMSLICE - WGRUPPE | Winding group | ||
| 135 | REG42_ZW - AB | Date from which time slice is valid | ||
| 136 | REG42_ZW - BIS | Date at Which a Time Slice Expires | ||
| 137 | REG42_ZW - EQUNR | Equipment Number | ||
| 138 | REG42_ZW - GERAET | Device | ||
| 139 | REG42_ZW - MANDT | Client | ||
| 140 | REG42_ZW - MASSBILL | Unit of measurement for billing | ||
| 141 | REG42_ZW - MASSBILLC6 | Unit of measurement for billing | ||
| 142 | REG42_ZW - MASSREAD | Unit of measurement for meter reading | ||
| 143 | REG42_ZW - MATNR | Material Number | ||
| 144 | REG42_ZW - MEINS | Unit of measurement for meter reading | ||
| 145 | REG42_ZW - NEW_ETDZ | Indicators | ||
| 146 | REG42_ZW - ZWNUMMER | Register | ||
| 147 | REG42_ZW_INPUT - MASSBILLC6 | Unit of measurement for billing | ||
| 148 | REG42_ZW_INPUT - MEINS | Unit of measurement for meter reading | ||
| 149 | REG42_ZW_INPUT_FLAG - AB | Date from which time slice is valid | ||
| 150 | REG42_ZW_INPUT_FLAG - BIS | Date at Which a Time Slice Expires | ||
| 151 | REG42_ZW_INPUT_FLAG - EQUNR | Equipment Number | ||
| 152 | REG42_ZW_INPUT_FLAG - GERAET | Device | ||
| 153 | REG42_ZW_INPUT_FLAG - MATNR | Device category | ||
| 154 | REG42_ZW_INPUT_FLAG - ZWNUMMER | Register | ||
| 155 | REG42_ZW_INPUT_FLAG_KEY - AB | Date from which time slice is valid | ||
| 156 | REG42_ZW_INPUT_FLAG_KEY - BIS | Date at Which a Time Slice Expires | ||
| 157 | REG42_ZW_INPUT_FLAG_KEY - EQUNR | Equipment Number | ||
| 158 | REG42_ZW_INPUT_FLAG_KEY - GERAET | Device | ||
| 159 | REG42_ZW_INPUT_FLAG_KEY - MATNR | Device category | ||
| 160 | REG42_ZW_INPUT_FLAG_KEY - ZWNUMMER | Register | ||
| 161 | REG42_ZW_INPUT_LAST_TIMSLICE - MASSBILLC6 | Unit of measurement for billing | ||
| 162 | REG42_ZW_INPUT_LAST_TIMSLICE - MEINS | Unit of measurement for meter reading | ||
| 163 | REG75 - ANLAGE | Installation | ||
| 164 | REG75 - DEVLOC | Device Location | ||
| 165 | REG75 - GERAET | Device | ||
| 166 | REG75 - STICHTAG | Key Date for Selection According to Time-Related Validity | ||
| 167 | REGEN - BAUSTEIN | Name of Function Module | ||
| 168 | REGEN - KENNZX | Indicators | ||
| 169 | REGEN - NO_CHANGE | No change allowed | ||
| 170 | REGEN - NO_DIALOG | Suppress maintenance screens | ||
| 171 | REGEN - NO_OTHER | No other object permitted | ||
| 172 | REGEN - NO_UPDATE | Suppress database update | ||
| 173 | REGEN - PROGRAMM | ABAP Program Name | ||
| 174 | REGEN - TITEL | Window title | ||
| 175 | REGEN - UPD_ONLINE | Update online | ||
| 176 | REGEN - WMODE | Processing mode (1 = display, 2 = change, 3 = create...) | ||
| 177 | SWOTOBJID - OBJTYPE | Object Type | ||
| 178 | SYST - DATUM | ABAP System Field: Current Date of Application Server | ||
| 179 | SYST - LANGU | ABAP System Field: Language Key of Text Environment | ||
| 180 | SYST - MANDT | ABAP System Field: Client ID of Current User | ||
| 181 | SYST - MSGID | ABAP System Field: Message ID | ||
| 182 | SYST - MSGNO | ABAP System Field: Message Number | ||
| 183 | SYST - MSGV1 | ABAP System Field: Message Variable | ||
| 184 | SYST - MSGV2 | ABAP System Field: Message Variable | ||
| 185 | SYST - MSGV3 | ABAP System Field: Message Variable | ||
| 186 | SYST - MSGV4 | ABAP System Field: Message Variable | ||
| 187 | SYST - TABIX | ABAP System Field: Row Index of Internal Tables | ||
| 188 | TE100 - EG30CUSTOM001 | Parameters for device installation, removal, and replacement | ||
| 189 | V_EGER - AB | Date from which time slice is valid | ||
| 190 | V_EGER - BIS | Date at Which a Time Slice Expires | ||
| 191 | V_EGER - DEVLOC | Device Location | ||
| 192 | V_EGER - EQUNR | Equipment Number | ||
| 193 | V_EGER - GERAET | Serial Number | ||
| 194 | V_EGER - LOGIKNR | Logical device number | ||
| 195 | V_EGER - MATNR | Material Number | ||
| 196 | V_EGER - SPARTE | Division |