Message Text
Assignment IP to material not consistent; configure profile
Help Document

Diagnosis

The assignment of the material master data to IP data is in the Customizing profile for stock calculation not in the same way as in the Customizing for the SPEC2K-Interface für ATA SPEC 2000.

System Response

The system cannot assign the material master data to IP data.

Procedure

The system assigns a material to the IP part type (manufacturer data) in accordance with the settings in the following profiles:

You have to assign the material master data to IP data in the same way as in the Customizing for the SPEC2K-Interface für ATA SPEC 2000. For information on the settings, see the documentation on Customizing for Logistic - General under SPEC2K-Interface für ATA SPEC 2000 -> Maintain IP Mapping and Profiles.

  • MPN=PNR, Manufacturer=MFR
    • The part number (field PNR in the table SPIPPDR) in the IP database is assigned to the manufacturer part number (field MFRPN in the table MARA) in the material master.
    • The manufacturer code (field MFR in the table SPIPPDR)in the IP database is assigned to the manufacturer number (field MFRNR in the table MARA)in the material master.
  • User-defined by Customer Exit
    • If the assignment is not as described above, you must select User-defined by Customer Exit.
    • The assignment has to be programed in a the SAP enhancement ALGEX004.