SAP ABAP Message Class FRMLCALC (Formula Calculations)
Basic Data
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
PLM-RM (Application Component) Recipe Management
⤷
RMSFRMGEN (Package) Generic Calculations

⤷

⤷

Attributes
Message class | ![]() |
FRMLCALC |
Short Description | ![]() |
Formula Calculations |
Changed On | ![]() |
20100310 |
Last Changed At | ![]() |
200156 |
Messages
# | Message | Message Short Text | Documentation status | Authorization check |
---|---|---|---|---|
1 | ![]() |
Determination of density not possible; field &1 missing in structure &2 | Space: object requires documentation | |
2 | ![]() |
Overflow during conversion in field &1 | Space: object requires documentation | |
3 | ![]() |
Reference quantity (&1) does not exist | The short text describes the object sufficiently | |
4 | ![]() |
No SI unit defined in Customizing for dimension &1 | Space: object requires documentation | |
5 | ![]() |
Conversion from &1 to &2 is not possible for stream &3 | Space: object requires documentation | |
6 | ![]() |
Obligatory parameter &1 is not filled or contains illegal value | Space: object requires documentation | |
7 | ![]() |
Dimension cannot be determined for &1 | The short text describes the object sufficiently | |
8 | ![]() |
Specification &1: Conversion factor for density cannot be determined | Space: object requires documentation | |
9 | ![]() |
Reference quantity in &1 cannot be converted to &2 &3 &4 | The short text describes the object sufficiently | |
10 | ![]() |
Conversion from &2 to &3 is not possible for material or substance &1 | Space: object requires documentation | |
11 | ![]() |
Material & not found | The short text describes the object sufficiently | |
12 | ![]() |
Formula does not contain any items with the evap. or absorption substance | Space: object requires documentation | |
13 | ![]() |
System error in instantiation &1 | The short text describes the object sufficiently | |
14 | ![]() |
Cost calculation is not possible; base quantity is zero | The short text describes the object sufficiently | |
15 | ![]() |
Error occurred when writing the property data &1 | The short text describes the object sufficiently | |
16 | ![]() |
Conversion from &1 to &2 is not possible for specification &3 | Space: object requires documentation | |
17 | ![]() |
Conversion is not possible; unit of measure (&1) was not specified | Space: object requires documentation | |
18 | ![]() |
Conversion is not possible; item data is missing | Space: object requires documentation | |
19 | ![]() |
Choose a unit of dimension mass or volume for primary output | Space: object requires documentation | |
20 | ![]() |
Calculation of density of primary output is not possible | Space: object requires documentation | |
21 | ![]() |
Calculation of primary output not possible; reference values are missing | Space: object requires documentation | |
22 | ![]() |
Calculation is not possible; no formula header data was specified | Space: object requires documentation | |
23 | ![]() |
Calculation is not possible; neither inputs nor outputs exist | Space: object requires documentation | |
24 | ![]() |
Unit &1 does not exist; choose a unit that does | Space: object requires documentation | |
25 | ![]() |
Component type &1 is not relevant for calculation | The short text describes the object sufficiently | |
26 | ![]() |
Calculation of total solids or mass for item &1 is not possible | Space: object requires documentation | |
27 | ![]() |
Volume for item &1 was taken from aeration volume | Space: object requires documentation | |
28 | ![]() |
Conversion factor for aeration density of item &1 not found | The short text describes the object sufficiently | |
29 | ![]() |
Internal error when calculating total of formula items | Space: object requires documentation | |
30 | ![]() |
System of equations calculation tool could not be instantiated | The short text describes the object sufficiently | |
31 | ![]() |
System of equations calculation expert failed | The short text describes the object sufficiently | |
32 | ![]() |
General error when resolving system of equations | The short text describes the object sufficiently | |
33 | ![]() |
Calculation terminated; current formula does not contain a primary output | Space: object requires documentation | |
34 | ![]() |
Unit for target input quantity does not exist | Space: object requires documentation | |
35 | ![]() |
Aeration volume of &1 (item &2) was not calculated | Space: object requires documentation | |
36 | ![]() |
Calculation routine for primary output does not exist | Space: object requires documentation | |
37 | ![]() |
Value in field &1 was calculated via material master for material &2 | Space: object requires documentation | |
38 | ![]() |
Target input quantity is not current, formula is inconsistent | Space: object requires documentation | |
39 | ![]() |
Calculation of value for &1 in row &2 results in too large a value | Space: object requires documentation | |
40 | ![]() |
Subst.&1 is aggregated; only non-initial tolerance limits cumulated (&2) | The short text describes the object sufficiently | |
41 | ![]() |
System calculated negative value (&1) for primary output | Space: object requires documentation | |
42 | ![]() |
Formula &1: Max. theoret. output is transferred to best practical output | Space: object requires documentation | |
43 | ![]() |
System prefers specification data to material data in calculations | Space: object requires documentation | |
44 | ![]() |
Table was aggregated for saving (merge substance totals is active) | Space: object requires documentation | |
45 | ![]() |
Substance &1 was filtered out because of incorrect component type &2 | Space: object requires documentation | |
46 | ![]() |
Formula is not consistent | Space: object requires documentation | |
47 | ![]() |
Stream in formula &3: Conversion from &1 to &2 is not possible | Space: object requires documentation | |
48 | ![]() |
Values in following value assignment types are overwritten with zero: &1 | Space: object requires documentation | |
49 | ![]() |
Subsequent stages were recalculated successfully | The short text describes the object sufficiently | |
50 | ![]() |
Stream in formula &3 has no composition | Space: object requires documentation | |
51 | ![]() |
Substance &1 with component type &2 is not relevant for calculation | Space: object requires documentation | |
52 | ![]() |
Data will be abandoned; formula view &1 cannot update formula | Space: object requires documentation | |
53 | ![]() |
Error in formula &1: Recalculation was canceled | Space: object requires documentation | |
54 | ![]() |
System calculates the energy values by multiplying by &1 | Space: object requires documentation | |
55 | ![]() |
Conversion between currencies &1 and &2 is not possible | Space: object requires documentation | |
56 | ![]() |
System cannot calculate calculated price | The short text describes the object sufficiently | |
57 | ![]() |
Multiple active BAdI implementations exist | Space: object requires documentation | |
58 | ![]() |
Transfer of composition from output substance (&1 with quantity: &2 &3) | The short text describes the object sufficiently | |
59 | ![]() |
Deviations occurred when calculating the quantity of primary output &1 | Space: object requires documentation |
History
Last changed on/by | ![]() |
20100310 | SAP |
SAP Release Created in | 600 |