SAP ABAP Interface IWCI_RCM_CASE_SP_VIS (Web Dynpro Interface COMPONENTCONTROLLER)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-SRV-CM (Application Component) Case Management
⤷ SCMG_SP_CASE_WD (Package) Service Provider Case: ABAP-Web Dynpro Visualization
⤷ BC-SRV-CM (Application Component) Case Management
⤷ SCMG_SP_CASE_WD (Package) Service Provider Case: ABAP-Web Dynpro Visualization
Properties
Interface | IWCI_RCM_CASE_SP_VIS | |
Short Description | Web Dynpro Interface COMPONENTCONTROLLER |
General Data
Package | SCMG_SP_CASE_WD | Service Provider Case: ABAP-Web Dynpro Visualization |
Created | 20041126 | SAP |
Last changed | 20090618 | SAP |
Unicode checks active |
Forward declarations
Interface IWCI_RCM_CASE_SP_VIS has no forward declaration.
Interfaces
Interface IWCI_RCM_CASE_SP_VIS has no interface.
Friends
Interface IWCI_RCM_CASE_SP_VIS has no friend.
Attributes
Interface IWCI_RCM_CASE_SP_VIS has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CHECK_TRANSITION | Instance method | Public | Method | 20041126 | |
2 | DO_TRANSITION | Instance method | Public | Method | 20041126 | |
3 | GET_TRANSITIONS | Instance method | Public | Method | 20041126 | |
4 | SET_BACKEND | Instance method | Public | Method | 20041126 | |
5 | SET_POID | Instance method | Public | Method | 20041126 | |
6 | WD_GET_API | Instance method | Public | Method | 20041126 |
Events
Interface IWCI_RCM_CASE_SP_VIS has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | ELEMENTS_FROM_SP | Public | See coding | 20041126 | Elements_From_Sp type
standard table of Element_From_Sp
with default key
|
||
2 | ELEMENTS_UI_ATTRIBUTES | Public | See coding | 20041126 | Elements_Ui_Attributes type
standard table of Element_Ui_Attributes
with default key
|
||
3 | ELEMENT_FROM_SP | Public | See coding | 20041126 | begin of Element_From_Sp,
DESCRIPTION type String,
PICT_URL type String,
end of Element_From_Sp
|
||
4 | ELEMENT_UI_ATTRIBUTES | Public | See coding | 20041126 | begin of Element_Ui_Attributes,
INPUTFIELDS_ENABLED type Wdy_Boolean,
SAVEBUTTON_ENABLED type Wdy_Boolean,
IS_VISIBLE type Wdui_Visibility,
end of Element_Ui_Attributes
|
Method Signatures
Method CHECK_TRANSITION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CURRENT_STATE | Call by reference | Object reference (TYPE REF TO) | CL_RCM_STATE | 20041126 | |||
2 | Returning | RE_IS_ALLOWED | Value transfer | Type reference (TYPE) | SRMBOOLEAN | 20041126 | |||
3 | Importing | SILENT_MODE | Call by reference | Type reference (TYPE) | SRMBOOLEAN | 20041126 | |||
4 | Importing | TRANSITION | Call by reference | Type reference (TYPE) | RCM_WD_TRANSITION | 20041126 |
Method CHECK_TRANSITION on Interface IWCI_RCM_CASE_SP_VIS has no exception.
Method DO_TRANSITION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CURRENT_STATE | Call by reference | Object reference (TYPE REF TO) | CL_RCM_STATE | 20041126 | |||
2 | Returning | RE_EXCEPTION | Value transfer | Object reference (TYPE REF TO) | CX_ROOT | 20041126 | |||
3 | Importing | SILENT_MODE | Call by reference | Type reference (TYPE) | SRMBOOLEAN | 20041126 | |||
4 | Importing | TRANSITION | Call by reference | Type reference (TYPE) | RCM_WD_TRANSITION | 20041126 |
Method DO_TRANSITION on Interface IWCI_RCM_CASE_SP_VIS has no exception.
Method GET_TRANSITIONS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_CURRENT_STATE | Call by reference | Object reference (TYPE REF TO) | CL_RCM_STATE | 20041126 | |||
2 | Returning | RE_TRANSITIONS | Value transfer | Type reference (TYPE) | RCM_WD_TRANSITION_GR_T | 20041126 |
Method GET_TRANSITIONS on Interface IWCI_RCM_CASE_SP_VIS has no exception.
Method SET_BACKEND Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | CX_CONNECTION_FAILURE | Value transfer | Object reference (TYPE REF TO) | CX_ROOT | 20041126 | |||
2 | Importing | MY_BACKEND | Call by reference | Object reference (TYPE REF TO) | OBJECT | 20041126 |
Method SET_BACKEND on Interface IWCI_RCM_CASE_SP_VIS has no exception.
Method SET_POID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_POID | Call by reference | Object reference (TYPE REF TO) | IF_SRM_POID | 20041126 | |||
2 | Importing | IM_SOURCE_POID | Call by reference | Object reference (TYPE REF TO) | IF_SRM_POID | 20050608 |
Method SET_POID on Interface IWCI_RCM_CASE_SP_VIS has no exception.
Method WD_GET_API Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_WD_CONTROLLER | 20041126 |
Method WD_GET_API on Interface IWCI_RCM_CASE_SP_VIS has no exception.
History
Last changed by/on | SAP | 20090618 |
SAP Release Created in | 710 |