SAP ABAP Interface IWCI_FDT_IWD_QUERY (WebDynpro Interface INTERFACECONTROLLER)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-SRV-BR (Application Component) BRFplus - ABAP-Based Business Rules
⤷ SFDT_WD_CORE_OBJECTS (Package) BRFplus: Core Objects for Web Dynpro UI
⤷ BC-SRV-BR (Application Component) BRFplus - ABAP-Based Business Rules
⤷ SFDT_WD_CORE_OBJECTS (Package) BRFplus: Core Objects for Web Dynpro UI
Properties
Interface | IWCI_FDT_IWD_QUERY | |
Short Description | WebDynpro Interface INTERFACECONTROLLER |
General Data
Package | SFDT_WD_CORE_OBJECTS | BRFplus: Core Objects for Web Dynpro UI |
Created | 20060825 | SAP |
Last changed | 20130531 | SAP |
Unicode checks active |
Forward declarations
Interface IWCI_FDT_IWD_QUERY has no forward declaration.
Interfaces
Interface IWCI_FDT_IWD_QUERY has no interface.
Friends
Interface IWCI_FDT_IWD_QUERY has no friend.
Attributes
Interface IWCI_FDT_IWD_QUERY has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ADVANCED_QUERY | Instance method | Public | Method | 20061215 | |
2 | CONTEXT_QUERY | Instance method | Public | Method | 20060825 | |
3 | ELEMENT_QUERY | Instance method | Public | Method | 20060825 | |
4 | OBJECT_QUERY | Instance method | Public | Method | 20060825 | |
5 | WD_GET_API | Instance method | Public | Method | 20060825 |
Events
Interface IWCI_FDT_IWD_QUERY has no event.
Types
Interface IWCI_FDT_IWD_QUERY has no local type.
Method Signatures
Method ADVANCED_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_CALLING_OBJECT | Call by reference | Object reference (TYPE REF TO) | IF_FDT_ADMIN_DATA | 20070110 | |||
2 | Importing | IO_FILTER | Call by reference | Object reference (TYPE REF TO) | IF_FDT_WD_QUERY_FILTER | 20090220 | |||
3 | Importing | IS_OBJECT_CATEGORY_SEL | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>S_OBJECT_CATEGORY_SEL | 20080115 | |||
4 | Importing | IS_PRESET_OBJECT_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_WD_TYPES=>S_OBJECT_TYPE_EXTENDED | 20061215 | |||
5 | Importing | ITS_SELECTION | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>TS_SELECTION | 20090529 | |||
6 | Importing | IT_OBJECT_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_WD_TYPES=>T_OBJECT_TYPE_EXTENDED | 20061215 | |||
7 | Importing | IV_APPLICATION_ID | Call by reference | Type reference (TYPE) | FDT_UUID | 20061215 | |||
8 | Importing | IV_EMBEDDED | Call by reference | Type reference (TYPE) | BOOLE_D | 20080221 | |||
9 | Importing | IV_INITIAL_SEARCH | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_FALSE | 20061215 | ||
10 | Importing | IV_MULTIPLE_SELECTION | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_FALSE | 20061215 | ||
11 | Importing | IV_OK_BUTTON_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120530 | |||
12 | Importing | IV_PRESET_NAME | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>NAME | 20080221 | |||
13 | Importing | IV_QUERY_TITLE | Call by reference | Type reference (TYPE) | STRING | 20100712 | |||
14 | Importing | IV_RESULT_DO_ELEM_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>ELEMENT_TYPE | 20061215 | |||
15 | Importing | IV_RESULT_DO_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>DATA_OBJECT_TYPE | 20061215 |
Method ADVANCED_QUERY on Interface IWCI_FDT_IWD_QUERY has no exception.
Method CONTEXT_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_CALLING_OBJECT | Call by reference | Object reference (TYPE REF TO) | IF_FDT_ADMIN_DATA | 20070110 | |||
2 | Importing | IO_FILTER | Call by reference | Object reference (TYPE REF TO) | IF_FDT_WD_QUERY_FILTER | 20090220 | |||
3 | Importing | ITS_SELECTION | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>TS_SELECTION | 20090529 | |||
4 | Importing | IV_DATA_OBJECT_TYPE | Call by reference | Type reference (TYPE) | FDT_DATA_OBJECT_TYPE | 20060825 | |||
5 | Importing | IV_ELEMENT_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>ELEMENT_TYPE | 20070112 | |||
6 | Importing | IV_EMBEDDED | Call by reference | Type reference (TYPE) | BOOLE_D | 20081126 | |||
7 | Importing | IV_MULTIPLE_SELECTION | Call by reference | Type reference (TYPE) | BOOLE_D | 20060829 | |||
8 | Importing | IV_OBJECT_ID | Call by reference | Type reference (TYPE) | FDT_UUID | 20060825 | |||
9 | Importing | IV_OK_BUTTON_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120530 | |||
10 | Importing | IV_PRESET_NAME | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>NAME | 20120627 | |||
11 | Importing | IV_QUERY_TITLE | Call by reference | Type reference (TYPE) | STRING | 20100712 | |||
12 | Importing | IV_TYPE_FIXED | Call by reference | Type reference (TYPE) | BOOLE_D | 20060825 |
Method CONTEXT_QUERY on Interface IWCI_FDT_IWD_QUERY has no exception.
Method ELEMENT_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_CALLING_OBJECT | Call by reference | Object reference (TYPE REF TO) | IF_FDT_ADMIN_DATA | 20070110 | |||
2 | Importing | IO_FILTER | Call by reference | Object reference (TYPE REF TO) | IF_FDT_WD_QUERY_FILTER | 20090220 | |||
3 | Importing | IS_OBJECT_CATEGORY_SEL | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>S_OBJECT_CATEGORY_SEL | 20080118 | |||
4 | Importing | ITS_SELECTION | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>TS_SELECTION | 20090529 | |||
5 | Importing | IT_ELEMENT_TYPES | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>T_ELEMENT_TYPE | 20110204 | |||
6 | Importing | IV_APPLICATION_ID | Call by reference | Type reference (TYPE) | FDT_UUID | 20060829 | |||
7 | Importing | IV_ELEMENT_TYPE | Call by reference | Type reference (TYPE) | FDT_ELEMENT_TYPE | 20060825 | |||
8 | Importing | IV_INITIAL_SEARCH | Call by reference | Type reference (TYPE) | BOOLE_D | 20060825 | |||
9 | Importing | IV_MULTIPLE_SELECTION | Call by reference | Type reference (TYPE) | BOOLE_D | 20060829 | |||
10 | Importing | IV_OK_BUTTON_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120530 | |||
11 | Importing | IV_PRESET_NAME | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>NAME | 20120627 | |||
12 | Importing | IV_QUERY_TITLE | Call by reference | Type reference (TYPE) | STRING | 20100712 | |||
13 | Importing | IV_TYPE_FIXED | Call by reference | Type reference (TYPE) | BOOLE_D | 20060825 |
Method ELEMENT_QUERY on Interface IWCI_FDT_IWD_QUERY has no exception.
Method OBJECT_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_CALLING_OBJECT | Call by reference | Object reference (TYPE REF TO) | IF_FDT_ADMIN_DATA | 20070110 | |||
2 | Importing | IO_FILTER | Call by reference | Object reference (TYPE REF TO) | IF_FDT_WD_QUERY_FILTER | 20090220 | |||
3 | Importing | IS_OBJECT_CATEGORY_SEL | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>S_OBJECT_CATEGORY_SEL | 20080118 | |||
4 | Importing | IS_OBJECT_TYPE | Call by reference | Type reference (TYPE) | IF_FDT_WD_TYPES=>S_OBJECT_TYPE_EXTENDED | 20060908 | |||
5 | Importing | ITS_SELECTION | Call by reference | Type reference (TYPE) | IF_FDT_QUERY=>TS_SELECTION | 20090529 | |||
6 | Importing | IV_APPLICATION_ID | Call by reference | Type reference (TYPE) | FDT_UUID | 20060829 | |||
7 | Importing | IV_EMBEDDED | Call by reference | Type reference (TYPE) | BOOLE_D | 20070118 | |||
8 | Importing | IV_INITIAL_SEARCH | Call by reference | Type reference (TYPE) | BOOLE_D | 20060825 | |||
9 | Importing | IV_MULTIPLE_SELECTION | Call by reference | Type reference (TYPE) | BOOLE_D | 20060829 | |||
10 | Importing | IV_OK_BUTTON_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120530 | |||
11 | Importing | IV_PRESET_NAME | Call by reference | Type reference (TYPE) | IF_FDT_TYPES=>NAME | 20120627 | |||
12 | Importing | IV_QUERY_TITLE | Call by reference | Type reference (TYPE) | STRING | 20100712 | |||
13 | Importing | IV_TYPE_FIXED | Call by reference | Type reference (TYPE) | BOOLE_D | 20060825 |
Method OBJECT_QUERY on Interface IWCI_FDT_IWD_QUERY has no exception.
Method WD_GET_API Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_WD_CONTROLLER | 20060825 |
Method WD_GET_API on Interface IWCI_FDT_IWD_QUERY has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 710 |