SAP ABAP Interface IWCI_DB6_SELECTION_DRILLDOWN (WebDynpro Interface COMPONENTCONTROLLER)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-DB-DB6-CCM (Application Component) CCMS / Database Monitors for DB2 Universal Database
⤷ STU6_WEBDYNPRO (Package) DB6: WebDynpro UI of DBA Cockpit
⤷ BC-DB-DB6-CCM (Application Component) CCMS / Database Monitors for DB2 Universal Database
⤷ STU6_WEBDYNPRO (Package) DB6: WebDynpro UI of DBA Cockpit
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DB6_GUI_SELECTION_DRILLDOWN | DBA Cockpit: SAPGUI Drilldown Selection | 20121001 |
Properties
Interface | IWCI_DB6_SELECTION_DRILLDOWN | |
Short Description | WebDynpro Interface COMPONENTCONTROLLER |
General Data
Package | STU6_WEBDYNPRO | DB6: WebDynpro UI of DBA Cockpit |
Created | 20110706 | SAP |
Last changed | 20130531 | SAP |
Unicode checks active |
Forward declarations
Interface IWCI_DB6_SELECTION_DRILLDOWN has no forward declaration.
Interfaces
Interface IWCI_DB6_SELECTION_DRILLDOWN has no interface.
Friends
Interface IWCI_DB6_SELECTION_DRILLDOWN has no friend.
Attributes
Interface IWCI_DB6_SELECTION_DRILLDOWN has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | GET_ACTIVE_SELECTION | Instance method | Public | Method | 20110706 | |
2 | SET_DISPLAY_MEMBER | Instance method | Public | Method | 20110706 | |
3 | SET_DISPLAY_METRIC | Instance method | Public | Method | 20110706 | |
4 | SET_DISPLAY_NONE | Instance method | Public | Method | 20110706 | |
5 | SET_DISPLAY_PARTITION | Instance method | Public | Method | 20121010 | |
6 | SET_DISPLAY_SC | Instance method | Public | Method | 20110706 | |
7 | SET_DISPLAY_TBSP | Instance method | Public | Method | 20110706 | |
8 | SET_DISPLAY_TOP_N_ONLY | Instance method | Public | Method | 20110706 | |
9 | SET_FIRST_LABEL_WIDTH | Instance method | Public | Method | 20110706 | |
10 | SET_INVISIBLE | Instance method | Public | Method | 20110706 | |
11 | SET_SELECTION | Instance method | Public | Method | 20110706 | |
12 | SET_VISIBLE | Instance method | Public | Method | 20110706 | |
13 | SYSTEM_CHANGED | Instance method | Public | Method | 20110706 | |
14 | WD_GET_API | Instance method | Public | Method | 20110706 |
Events
Interface IWCI_DB6_SELECTION_DRILLDOWN has no event.
Types
Interface IWCI_DB6_SELECTION_DRILLDOWN has no local type.
Method Signatures
Method GET_ACTIVE_SELECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | SELECTION | Call by reference | Type reference (TYPE) | STRING | 20110706 | |||
2 | Exporting | TOP_N_ONLY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method GET_ACTIVE_SELECTION on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_MEMBER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_MEMBER on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_METRIC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_METRIC on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_NONE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_NONE on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_PARTITION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20121010 |
Method SET_DISPLAY_PARTITION on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_SC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_SC on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_TBSP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_TBSP on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_DISPLAY_TOP_N_ONLY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | DISPLAY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_DISPLAY_TOP_N_ONLY on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_FIRST_LABEL_WIDTH Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | WIDTH | Call by reference | Type reference (TYPE) | STRING | 20110706 |
Method SET_FIRST_LABEL_WIDTH on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_INVISIBLE Signature
Method SET_INVISIBLE on Interface IWCI_DB6_SELECTION_DRILLDOWN has no parameter.
Method SET_INVISIBLE on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_SELECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | SELECTION | Call by reference | Type reference (TYPE) | STRING | 20110706 | |||
2 | Importing | TOP_N_ONLY | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | 20110706 |
Method SET_SELECTION on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SET_VISIBLE Signature
Method SET_VISIBLE on Interface IWCI_DB6_SELECTION_DRILLDOWN has no parameter.
Method SET_VISIBLE on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method SYSTEM_CHANGED Signature
Method SYSTEM_CHANGED on Interface IWCI_DB6_SELECTION_DRILLDOWN has no parameter.
Method SYSTEM_CHANGED on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
Method WD_GET_API Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_WD_CONTROLLER | 20110706 |
Method WD_GET_API on Interface IWCI_DB6_SELECTION_DRILLDOWN has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 731 |