SAP ABAP Interface IWCI_C_SRT_WS_PROVIDER_SEC (WebDynpro Interface COMPONENTCONTROLLER)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-ESI-WS-ABA-CFG (Application Component) WebServices ABAP Configuration
     SOA_MANAGER_ABAP_UI (Package) SOA Manager: User Interaction ABAP Stack
Properties
Interface IWCI_C_SRT_WS_PROVIDER_SEC  
Short Description WebDynpro Interface COMPONENTCONTROLLER    
General Data
Package SOA_MANAGER_ABAP_UI   SOA Manager: User Interaction ABAP Stack 
Created 20121011   SAP 
Last changed 20140121   SAP 
Unicode checks active    
Forward declarations
Interface IWCI_C_SRT_WS_PROVIDER_SEC has no forward declaration.
Interfaces
Interface IWCI_C_SRT_WS_PROVIDER_SEC has no interface.
Friends
Interface IWCI_C_SRT_WS_PROVIDER_SEC has no friend.
Attributes
Interface IWCI_C_SRT_WS_PROVIDER_SEC has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHECK Instance method Public Method 20121019
2 CHECK_FOR_DATA_LOSS Instance method Public Method 20121204
3 CLEAR_CONFIGURATION Instance method Public Method 20121018
4 GET_BINDING_PROPERTIES Instance method Public Method 20130222
5 RESET_CHANGE Instance method Public Method 20121204
6 SET_CONFIGURATION Instance method Public Method 20121017
7 WD_GET_API Instance method Public Method 20121011
Events
Interface IWCI_C_SRT_WS_PROVIDER_SEC has no event.
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 ELEMENTS_ALL_VIEWS_ATTR Public See coding 20121016 Elements_all_views_attr type standard table of Element_all_views_attr with default key
2 ELEMENT_ALL_VIEWS_ATTR Public See coding 20121016 begin of Element_all_views_attr, READ_ONLY type Wdy_Boolean, READ_ONLY_TRUE type Wdy_Boolean, end of Element_all_views_attr
Method Signatures

Method CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_MESSAGES Call by reference Type reference (TYPE) SOAP_ERROR_INFO_LIST 20121130
2 Exporting E_OK Call by reference Type reference (TYPE) BOOLEAN 20121130

Method CHECK on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method CHECK_FOR_DATA_LOSS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_DATALOSS Value transfer Type reference (TYPE) BOOLEAN 20121204

Method CHECK_FOR_DATA_LOSS on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method CLEAR_CONFIGURATION Signature

Method CLEAR_CONFIGURATION on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no parameter.
Method CLEAR_CONFIGURATION on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method GET_BINDING_PROPERTIES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RT_BINDING_PROP Value transfer Type reference (TYPE) SRT_UI_SC_PROP_INFO_LIST 20130222

Method GET_BINDING_PROPERTIES on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method RESET_CHANGE Signature

Method RESET_CHANGE on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no parameter.
Method RESET_CHANGE on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method SET_CONFIGURATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IR_BINDING Call by reference Object reference (TYPE REF TO) IF_SRT_WSP_SUBJECT_BINDING 20121017
2 Importing IR_CONFIG Call by reference Object reference (TYPE REF TO) IF_SRT_WSP_CONFIG_RT 20121017
3 Importing I_CREATED Call by reference Type reference (TYPE) BOOLEAN ABAP_TRUE 20130214
4 Importing I_EXTERNAL_NAME Call by reference Type reference (TYPE) QNAME 20121207
5 Importing I_PROVIDER_NAME Call by reference Type reference (TYPE) SRT_WSP_DT_OBJ_NAME 20121207

Method SET_CONFIGURATION on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.

Method WD_GET_API Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RESULT Value transfer Object reference (TYPE REF TO) IF_WD_CONTROLLER 20121011

Method WD_GET_API on Interface IWCI_C_SRT_WS_PROVIDER_SEC has no exception.
History
Last changed by/on SAP  20140121 
SAP Release Created in 740