SAP ABAP Interface IF_SRT_WSP_RT_CONFIG_SETUP (WSP Configuration Runtime Object)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-ESI-WS-ABA-CFG (Application Component) WebServices ABAP Configuration
⤷
SOAP_CONFIG (Package) SOAP Configuration Framework

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_RT_CONFIG | WSP Configuration Runtime Object | 20050919 |
Properties
Interface | IF_SRT_WSP_RT_CONFIG_SETUP | |
Short Description | WSP Configuration Runtime Object |
General Data
Package | SOAP_CONFIG | SOAP Configuration Framework |
Created | 20050919 | SAP |
Last changed | 20090618 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | TSRTP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_SRT_WSP_RT_CONFIG | WSP Configuration Runtime Object | 20050919 |
Friends
Interface IF_SRT_WSP_RT_CONFIG_SETUP has no friend.
Attributes
Interface IF_SRT_WSP_RT_CONFIG_SETUP has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | 20050919 | |
2 | ![]() |
Instance method | Public | Method | 20051014 | |
3 | ![]() |
Instance method | Public | Method | 20050919 | |
4 | ![]() |
Instance method | Public | Method | 20050919 | |
5 | ![]() |
Instance method | Public | Method | 20050919 | |
6 | ![]() |
Instance method | Public | Method | 20050919 | |
7 | ![]() |
Instance method | Public | Method | 20050919 | |
8 | ![]() |
Instance method | Public | Method | 20050919 |
Events
Interface IF_SRT_WSP_RT_CONFIG_SETUP has no event.
Types
Interface IF_SRT_WSP_RT_CONFIG_SETUP has no local type.
Method Signatures
Method ADD_OPERATION_CONFIG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CONFIG | Call by reference | Type reference (TYPE) | SRT_RT_OPERATION_CONFIG | WSP RT operation specific configuration | 20050919 |
Method ADD_OPERATION_CONFIG on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method CLONE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CONFIG | Value transfer | Object reference (TYPE REF TO) | IF_SRT_WSP_RT_CONFIG_SETUP | WSP configuration runtime object | 20051014 |
Method CLONE on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_DT_OBJ_NAME Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
DT_OBJ_NAME | Call by reference | Type reference (TYPE) | SRT_WSP_DT_OBJ_NAME | WSP name of the interface object | 20050919 |
Method SET_DT_OBJ_NAME on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_ENDPOINT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ENDPOINT | Call by reference | Type reference (TYPE) | SRT_WSP_ENDPOINT_TYPE | WSP endpoint type | 20050919 |
Method SET_ENDPOINT on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_GLOBAL_CONFIG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CONFIG | Call by reference | Type reference (TYPE) | SRT_RT_PROPERTIES | SRT properties for RT | 20050919 |
Method SET_GLOBAL_CONFIG on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_LOCATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
LOCATION | Call by reference | Type reference (TYPE) | I | 20050919 |
Method SET_LOCATION on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_OPERATION_CONFIGS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
OPERATIONS | Call by reference | Type reference (TYPE) | SRT_RT_OPERATION_CONFIGS | WSP table of RT operation specific configurations | 20050919 |
Method SET_OPERATION_CONFIGS on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
Method SET_SOAP_APPL_NAME Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
SOAP_APPL_NAME | Call by reference | Type reference (TYPE) | SRT_WSP_SOAP_APPL_NAME | WSP name of the SOAP Application | 20050919 |
Method SET_SOAP_APPL_NAME on Interface IF_SRT_WSP_RT_CONFIG_SETUP has no exception.
History
Last changed by/on | SAP | 20090618 |
SAP Release Created in | 710 |