SAP ABAP Interface IF_SRT_WSP_CONNECTIVITY_BADI (Interface for BAdI: SSRT_WSP_CONNECTIVITY_BADI)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-ESI-WS-ABA-CFG (Application Component) WebServices ABAP Configuration
⤷
SOAP_CONFIG (Package) SOAP Configuration Framework

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_CDTC_REMOTE | Central Design Time Cache: Connectivity Implementation | 20110113 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_CENTRAL_CONFIG_IMPL | 20110114 | |
3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_CONFIG_LOG_CENTRAL | 20110114 | |
4 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_CTRL_HEALTH_CHECK | 20110609 | |
5 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_IBC_SYNC | SRT: Synchronize IBC's | 20120608 |
6 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SRT_WSP_SR_SETUP_BADI | Class for BAdI: SSRT_WSP_CONNECTIVITY_BADI | 20110311 |
Properties
Interface | IF_SRT_WSP_CONNECTIVITY_BADI | |
Short Description | Interface for BAdI: SSRT_WSP_CONNECTIVITY_BADI |
General Data
Package | SOAP_CONFIG | SOAP Configuration Framework |
Created | 20110114 | SAP |
Last changed | 20110908 | SAP |
Unicode checks active |
Forward declarations
Interface IF_SRT_WSP_CONNECTIVITY_BADI has no forward declaration.
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20110114 |
Friends
Interface IF_SRT_WSP_CONNECTIVITY_BADI has no friend.
Attributes
Interface IF_SRT_WSP_CONNECTIVITY_BADI has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Is called once after a managed system has been disconnected | 20110114 |
2 | ![]() |
Instance method | Public | Method | Is called once after a managed system has been connected | 20110114 |
3 | ![]() |
Instance method | Public | Method | "Connectivity": Processes application data | 20110114 |
4 | ![]() |
Instance method | Public | Method | Can be called when a managed system needs to synchronize | 20110114 |
Events
Interface IF_SRT_WSP_CONNECTIVITY_BADI has no event.
Types
Interface IF_SRT_WSP_CONNECTIVITY_BADI has no local type.
Method Signatures
Method CLEANUP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CENTRAL_SYSTEM | Call by reference | Type reference (TYPE) | BOOLEAN | 20110114 | |||
2 | ![]() |
TRIGGERING_SYSTEM_TENANT_KEY | Call by reference | Type reference (TYPE) | SRT_WSP_CON_TENANT_KEY | 20110114 |
Method CLEANUP on Interface IF_SRT_WSP_CONNECTIVITY_BADI has no exception.
Method INITIALIZATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CENTRAL_SYSTEM | Call by reference | Type reference (TYPE) | BOOLEAN | 20110114 | |||
2 | ![]() |
TRIGGERING_SYSTEM_TENANT_KEY | Call by reference | Type reference (TYPE) | SRT_WSP_CON_TENANT_KEY | 20110114 |
Method INITIALIZATION on Interface IF_SRT_WSP_CONNECTIVITY_BADI has no exception.
Method PROCESS_XSTRING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
APPLICATION_INFO | Call by reference | Type reference (TYPE) | SSTR_CON_APPL_INFORMATION | 20110114 | |||
2 | ![]() |
APPLICATION_MESSAGE_ID | Call by reference | Type reference (TYPE) | SYMSGID | 20110114 | |||
3 | ![]() |
APPLICATION_MESSAGE_NUMBER | Call by reference | Type reference (TYPE) | SYMSGNO | 20110114 | |||
4 | ![]() |
APPLICATION_MESSAGE_TYPE | Call by reference | Type reference (TYPE) | SYMSGTY | 20110114 | |||
5 | ![]() |
APPLICATION_MESSAGE_V1 | Call by reference | Type reference (TYPE) | SYMSGV | 20110114 | |||
6 | ![]() |
APPLICATION_MESSAGE_V2 | Call by reference | Type reference (TYPE) | SYMSGV | 20110114 | |||
7 | ![]() |
APPLICATION_MESSAGE_V3 | Call by reference | Type reference (TYPE) | SYMSGV | 20110114 | |||
8 | ![]() |
APPLICATION_MESSAGE_V4 | Call by reference | Type reference (TYPE) | SYMSGV | 20110114 | |||
9 | ![]() |
APPLICATION_REQUEST | Call by reference | Type reference (TYPE) | SRT_WSP_CON_DATA_RAWSTRING | 20110114 | |||
10 | ![]() |
APPLICATION_RESPONSE | Call by reference | Type reference (TYPE) | XSTRING | 20110114 | |||
11 | ![]() |
APPLICATION_STATUS | Call by reference | Type reference (TYPE) | SRT_WSP_CON_REQUEST_STAT_APPL | 20110114 |
Method PROCESS_XSTRING on Interface IF_SRT_WSP_CONNECTIVITY_BADI has no exception.
Method SYNCHRONIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CENTRAL_SYSTEM | Call by reference | Type reference (TYPE) | BOOLEAN | 20110114 | |||
2 | ![]() |
TRIGGERING_SYSTEM_TENANT_KEY | Call by reference | Type reference (TYPE) | SRT_WSP_CON_TENANT_KEY | 20110114 |
Method SYNCHRONIZE on Interface IF_SRT_WSP_CONNECTIVITY_BADI has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in |