SAP ABAP Interface IF_SATC_RT_LOG_WRITER (Log writer for ATC runtime solely)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-DWB-TOO-ATF (Application Component) ABAP Test Frameworks ( ATC, CheckMan, Code Inspector)
     SATC_STDLIB_RUN_TIME_LOG (Package) INTERNAL: - *NO* REUSE - logging and tracing
Properties
Interface IF_SATC_RT_LOG_WRITER  
Short Description Log writer for ATC runtime solely    
General Data
Package SATC_STDLIB_RUN_TIME_LOG   INTERNAL: - *NO* REUSE - logging and tracing 
Created 20090805   SAP 
Last changed 20130531   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 IF_SATC_RT_LOG Forward declaration interface (INTERFACE i DEFINITION DEF...  Forward declaration interface (INTERFACE i DEFINITION DEF...
2 IF_SATC_RT_LOG_CONSTANTS Forward declaration interface (INTERFACE i DEFINITION DEF...  Forward declaration interface (INTERFACE i DEFINITION DEF...
Interfaces
Interface IF_SATC_RT_LOG_WRITER has no interface.
Friends
Interface IF_SATC_RT_LOG_WRITER has no friend.
Attributes
Interface IF_SATC_RT_LOG_WRITER has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 ADD_ERROR_FROM_EXCEPTION Instance method Public Method Add error message based for exception 20090805
2 ADD_ERROR_FROM_SYMSG Instance method Public Method Add error message based for SYMSG structure 20090805
3 ADD_ERROR_FROM_T100_MESSAGE Instance method Public Method Add info message based for T100 data 20090805
4 ADD_INFO_FROM_T100_MESSAGE Instance method Public Method Add info based for T100 data 20090805
5 ADD_INFO_FROM_TEXT Instance method Public Method Add info based for text sequence (max. 100 chars) 20090806
Events
Interface IF_SATC_RT_LOG_WRITER has no event.
Types
Interface IF_SATC_RT_LOG_WRITER has no local type.
Method Signatures

Method ADD_ERROR_FROM_EXCEPTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EXCEPTION Call by reference Object reference (TYPE REF TO) CX_ROOT Class Based Exception 20090805
2 Importing I_LEVEL Call by reference Type reference (TYPE) INT1 IF_SATC_RT_LOG_CONSTANTS=>C_LOG_LEVEL-SPARSE Level 20090805

Method ADD_ERROR_FROM_EXCEPTION on Interface IF_SATC_RT_LOG_WRITER has no exception.

Method ADD_ERROR_FROM_SYMSG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LEVEL Call by reference Type reference (TYPE) INT1 IF_SATC_RT_LOG_CONSTANTS=>C_LOG_LEVEL-SPARSE Log Level 20090805
2 Importing I_SYMSG Call by reference Type reference (TYPE) SYMSG Structure of message variables 20090805

Method ADD_ERROR_FROM_SYMSG on Interface IF_SATC_RT_LOG_WRITER has no exception.

Method ADD_ERROR_FROM_T100_MESSAGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LEVEL Call by reference Type reference (TYPE) INT1 IF_SATC_RT_LOG_CONSTANTS=>C_LOG_LEVEL-SPARSE Log Level 20090805
2 Importing MSGID Call by reference Type reference (TYPE) SYMSGID 'SATC_RUN_TIME' Message Class 20090805
3 Importing MSGNO Call by reference Type reference (TYPE) SYMSGNO Message Number 20090805
4 Importing MSGV1 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
5 Importing MSGV2 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
6 Importing MSGV3 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
7 Importing MSGV4 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805

Method ADD_ERROR_FROM_T100_MESSAGE on Interface IF_SATC_RT_LOG_WRITER has no exception.

Method ADD_INFO_FROM_T100_MESSAGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LEVEL Call by reference Type reference (TYPE) INT1 IF_SATC_RT_LOG_CONSTANTS=>C_LOG_LEVEL-CONCISE Trace Level 20090805
2 Importing MSGID Call by reference Type reference (TYPE) SYMSGID 'SATC_RUN_TIME' Message Class 20090805
3 Importing MSGNO Call by reference Type reference (TYPE) SYMSGNO Message Number 20090805
4 Importing MSGV1 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
5 Importing MSGV2 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
6 Importing MSGV3 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805
7 Importing MSGV4 Call by reference Type reference (TYPE) CSEQUENCE Message Variable 20090805

Method ADD_INFO_FROM_T100_MESSAGE on Interface IF_SATC_RT_LOG_WRITER has no exception.

Method ADD_INFO_FROM_TEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LEVEL Call by reference Type reference (TYPE) INT1 IF_SATC_RT_LOG_CONSTANTS=>C_LOG_LEVEL-CONCISE Log Level 20090806
2 Importing I_TEXT Call by reference Type reference (TYPE) CSEQUENCE Text Information (max. 100 Characters) 20090806

Method ADD_INFO_FROM_TEXT on Interface IF_SATC_RT_LOG_WRITER has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 800