SAP ABAP Interface IF_SATC_AC__UI_PLNERR_FILTER (Selection criteria for Plug-in error filter)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-DWB-TOO-ATF (Application Component) ABAP Test Frameworks ( ATC, CheckMan, Code Inspector)
⤷
SATC_ABAP_CHECK__UI (Package) INTERNAL: - *NO* REUSE - UI "CheckMan" style

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SATC_AC__UI_PLNERR_FILTER | Filter for Plug-in errors | 20091030 |
Properties
Interface | IF_SATC_AC__UI_PLNERR_FILTER | |
Short Description | Selection criteria for Plug-in error filter |
General Data
Package | SATC_ABAP_CHECK__UI | INTERNAL: - *NO* REUSE - UI "CheckMan" style |
Created | 20091030 | SAP |
Last changed | 20140121 | SAP |
Unicode checks active |
Forward declarations
Interface IF_SATC_AC__UI_PLNERR_FILTER has no forward declaration.
Interfaces
Interface IF_SATC_AC__UI_PLNERR_FILTER has no interface.
Friends
Interface IF_SATC_AC__UI_PLNERR_FILTER has no friend.
Attributes
Interface IF_SATC_AC__UI_PLNERR_FILTER has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Create a new instance with same attributes | 20091030 |
2 | ![]() |
Instance method | Public | Method | Get hash code | 20091030 |
3 | ![]() |
Instance method | Public | Method | Get additional criteria for 'Tool Failure' selection | 20091030 |
4 | ![]() |
Instance method | Public | Method | Get criteria for 'Finding' selection | 20091030 |
5 | ![]() |
Instance method | Public | Method | Contains the filter no restrictions | 20091030 |
6 | ![]() |
Instance method | Public | Method | Clear any criteria | 20091030 |
7 | ![]() |
Instance method | Public | Method | Set additional criteria for 'Tool Failure' selection | 20091030 |
8 | ![]() |
Instance method | Public | Method | Set criteria for 'Finding' selection | 20091030 |
Events
Interface IF_SATC_AC__UI_PLNERR_FILTER has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | TY_T_PLNERR_MESSAGE_KEYS | Public | See coding | 20091030 | ty_T_Plnerr_Message_Keys type range of if_Satc_Ac_Plnerr_Domain_Types=>ty_D_Message_Key
|
Method Signatures
Method CLONE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Object reference (TYPE REF TO) | IF_SATC_AC__UI_PLNERR_FILTER | 20091030 |
Method CLONE on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method GET_HASH Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Type reference (TYPE) | I | 20091030 |
Method GET_HASH on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method GET_PLNERR_MESSAGE_KEYS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Type reference (TYPE) | TY_T_PLNERR_MESSAGE_KEYS | 20091030 |
Method GET_PLNERR_MESSAGE_KEYS on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method GET_VDCT_FILTER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Object reference (TYPE REF TO) | IF_SATC_AC__UI_VDCT_FILTER | 20091030 |
Method GET_VDCT_FILTER on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method IS_INITIAL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20091030 |
Method IS_INITIAL on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method RESET Signature
Method RESET on Interface IF_SATC_AC__UI_PLNERR_FILTER has no parameter.
Method RESET on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method SET_PLNERR_MESSAGE_KEYS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_PLNERR_MESSAGE_KEYS | Call by reference | Type reference (TYPE) | TY_T_PLNERR_MESSAGE_KEYS | 20091030 |
Method SET_PLNERR_MESSAGE_KEYS on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
Method SET_VDCT_FILTER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_VDCT_FILTER | Call by reference | Object reference (TYPE REF TO) | IF_SATC_AC__UI_VDCT_FILTER | 20091030 |
Method SET_VDCT_FILTER on Interface IF_SATC_AC__UI_PLNERR_FILTER has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in | 800 |