SAP ABAP Interface IF_RMXT_TASK (TMS-TLS: Trial Monitor: Task Interface)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
PLM-RM (Application Component) Recipe Management
⤷
RMXTTLS (Package) Main Package - Trial: Tools

⤷

⤷

Meta Relationship - Used By
Properties
Interface | IF_RMXT_TASK | |
Short Description | TMS-TLS: Trial Monitor: Task Interface |
General Data
Package | RMXTTLS | Main Package - Trial: Tools |
Created | 20030305 | SAP |
Last changed | 20031212 | SAP |
Unicode checks active |
Forward declarations
Interface IF_RMXT_TASK has no forward declaration.
Interfaces
Interface IF_RMXT_TASK has no interface.
Friends
Interface IF_RMXT_TASK has no friend.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | MO_MONITOR | Instance attribute | Public | Object reference (TYPE REF TO) | IF_RMXT_MONITOR | Trial Monitor Instance | 20030416 | ||
2 | M_TASK | Instance attribute | Public | Type reference (TYPE) | RMXTE_TASK | Trial Monitor Task ID | 20030416 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Execute Task | 20030324 |
2 | ![]() |
Static method | Public | Method | Gets a Task Instance | 20030416 |
3 | ![]() |
Instance method | Public | Method | Additional Checks for Task Activity | 20030324 |
4 | ![]() |
Instance method | Public | Method | Additional Checks for Task Status | 20030324 |
Events
Interface IF_RMXT_TASK has no event.
Types
Interface IF_RMXT_TASK has no local type.
Method Signatures
Method EXECUTE_TASK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_MESSAGES | Call by reference | Type reference (TYPE) | RMXTTY_MESSAGES | Meldungen | 20030325 | ||
2 | ![]() |
E_FLG_NO_STAT | Call by reference | Type reference (TYPE) | FLAG | 'X' = Monitor soll System-/Userstatus nicht autom. setzen | 20030425 | ||
3 | ![]() |
IO_OBJ | Call by reference | Object reference (TYPE REF TO) | OBJECT | Objektinstanz mit Anwendungsdaten | 20030324 | ||
4 | ![]() |
I_DATA | Call by reference | Type reference (TYPE) | DATA | Zusätzliche Daten für die Maßnahme | 20030325 | ||
5 | ![]() |
I_FLG_BACKGROUND | Call by reference | Type reference (TYPE) | C | Kennz.: Maßnahme im Hintergrund ausführen | 20030912 | ||
6 | ![]() |
I_LOG_HANDLE | Call by reference | Type reference (TYPE) | BALLOGHNDL | Anwendungslog Handle zum Hinzufügen von Meldungen ins LOG | 20030710 | ||
7 | ![]() |
I_OBJNR | Call by reference | Type reference (TYPE) | J_OBJNR | Objektnummer aus der allg. Statusverwaltung | 20030417 | ||
8 | ![]() |
I_OBJ_ID | Call by reference | Type reference (TYPE) | STRING | Identifikation des Monitorverwenders | 20030417 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Abbruch durch den Benutzer | 20030915 | |
2 | ![]() |
Fehler bei der Massnahmenausführung - siehe Meldungstabelle | 20030325 |
Method GET_INSTANCE_CL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EO_TASK | Call by reference | Object reference (TYPE REF TO) | IF_RMXT_TASK | Maßnahmeninstanz | 20030416 | ||
2 | ![]() |
E_EXE_AT_DISP | Call by reference | Type reference (TYPE) | FLAG | Kennz.: Maßnahme im Anzeige-Modus ausführbar | 20030505 | ||
3 | ![]() |
E_FLG_SAVE | Call by reference | Type reference (TYPE) | FLAG | Kennz.: Maßnahme muss vor + nach Ausführung gesichert werden | 20030616 | ||
4 | ![]() |
E_VRNG | Call by reference | Type reference (TYPE) | J_VORGANG | Betr.wirtschaftl. Vorgang für die Maßnahmenausführung | 20030505 | ||
5 | ![]() |
IO_MONITOR | Call by reference | Object reference (TYPE REF TO) | IF_RMXT_MONITOR | Instanz des Monitors | 20030416 | ||
6 | ![]() |
I_TASK | Call by reference | Type reference (TYPE) | RMXTE_TASK | ID der Maßnahme | 20030416 |
Method GET_INSTANCE_CL on Interface IF_RMXT_TASK has no exception.
Method GET_TASK_ACTY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_OBJ | Call by reference | Object reference (TYPE REF TO) | OBJECT | Objektinstanz mit Anwendungsdaten | 20030324 | ||
2 | ![]() |
I_OBJNR | Call by reference | Type reference (TYPE) | J_OBJNR | Objektnummer aus der allg. Statusverwaltung | 20030423 | ||
3 | ![]() |
I_OBJ_ID | Call by reference | Type reference (TYPE) | STRING | ID des Monitorverwenders | 20030417 | ||
4 | ![]() |
X_TASK_ACTY | Call by reference | Type reference (TYPE) | RMXTE_TASK_ACTY | Aktivität Versuchsmonitormaßnahme | 20030324 |
Method GET_TASK_ACTY on Interface IF_RMXT_TASK has no exception.
Method GET_TASK_STAT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_DETL | Call by reference | Type reference (TYPE) | RMXTTY_MONI_TASK_DETAIL | zusätzliche Maßnahmenregeln (Anzeige auf Oberfläche) | 20030420 | ||
2 | ![]() |
IO_OBJ | Call by reference | Object reference (TYPE REF TO) | OBJECT | Objektinstanz mit Anwendungsdaten | 20030324 | ||
3 | ![]() |
I_OBJ_ID | Call by reference | Type reference (TYPE) | STRING | ID des Monitorverwenders | 20030417 |
Method GET_TASK_STAT on Interface IF_RMXT_TASK has no exception.
Meta Relationship - Used By (full list)
History
Last changed by/on | SAP | 20031212 |
SAP Release Created in | 471 |