SAP ABAP Interface IF_RMSA_STD_DIA (RMS-ATL: Object Spec. Check Methods for STD Interface)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   PLM-RM (Application Component) Recipe Management
     RMSATLSTD (Package) RMS-ATL: Standardization
Properties
Interface IF_RMSA_STD_DIA  
Short Description RMS-ATL: Object Spec. Check Methods for STD Interface    
General Data
Package RMSATLSTD   RMS-ATL: Standardization 
Created 20020820   SAP 
Last changed 20060711   SAP 
Unicode checks active    
Forward declarations
Interface IF_RMSA_STD_DIA has no forward declaration.
Interfaces
Interface IF_RMSA_STD_DIA has no interface.
Friends
Interface IF_RMSA_STD_DIA has no friend.
Attributes
Interface IF_RMSA_STD_DIA has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_ITEM Instance method Public Method Checking New/Changed Components and Determining Addit. Data 20020905
2 DISPLAY_LOG Instance method Public Method Displaying Messages (For Example: Application Log) 20021018
3 FILL_ADD_DATA Instance method Public Method Determining Addit.Data Before Displaying it on the Interface 20020902
4 HANDLE_MESSAGES Instance method Public Method Transfer of Contribution Class Messages 20021015
5 OKCODE Instance method Public Method Handling Own OK Codes 20030923
6 ON_DATA_CHANGED Instance method Public Method Data Is to Be Saved 20031022
7 ON_F4_HELP Instance method Public Method ALV Event: Call F4 Help for a Field 20020902
8 SELECT_STREAM Instance method Public Method Display Stream Selection Popup 20020902
Events
Interface IF_RMSA_STD_DIA has no event.
Types
Interface IF_RMSA_STD_DIA has no local type.
Method Signatures

Method CHECK_ITEM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IFLG_DISP_TS Call by reference Type reference (TYPE) RMSTE_FLAG Kennzeichen: Trockenmasse ermitteln 20020905
2 Importing IO_STD_CALC Call by reference Object reference (TYPE REF TO) CL_FRML_STD_SPEC RMS-FRM: Contribution/Composition 20051125
3 Importing IT_CHG_CELLS Call by reference Type reference (TYPE) LVC_T_MODI Tabelle der geänderten Zellen für die Komponente 20020905
4 Importing IT_ITEM Call by reference Type reference (TYPE) TABLE Komplette ALV Tabelle mit geänderten Werten 20020919
5 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20020905
6 Importing I_STDID Call by reference Type reference (TYPE) RMSAE_ID ID des Aufrufers (Formel RECN, ...) 20020905
7 Importing I_VALDAT Call by reference Type reference (TYPE) RMSAE_VALDAT Stichtag 20020905
8 Changing XS_ITEM Call by reference Type reference (TYPE) ANY Struktur mit geänderter ALV Zeile 20020905
9 Changing XT_PROTOCOL Call by reference Type reference (TYPE) LVC_T_MSG1 Fehlermeldungen für geänderter ALV Zeile 20020917
# Exception Resumable Description Created on
1 EXC_NOT_VALID Item ist nicht gültig 20020919

Method DISPLAY_LOG Signature

Method DISPLAY_LOG on Interface IF_RMSA_STD_DIA has no parameter.
Method DISPLAY_LOG on Interface IF_RMSA_STD_DIA has no exception.

Method FILL_ADD_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IFLG_DISP_TS Call by reference Type reference (TYPE) RMSTE_FLAG Kennzeichen: Trockenmasse ermitteln 20020902
2 Importing IO_STD_CALC Call by reference Object reference (TYPE REF TO) CL_FRML_STD_SPEC RMS-FRM: Contribution/Composition 20051125
3 Importing IT_COL_MAPPING Call by reference Type reference (TYPE) RMSATY_STD_COL_MAPPING Mappingtabelle für Spalten der Standardisierung 20030821
4 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20020902
5 Importing I_DATA_SOURCE Call by reference Type reference (TYPE) RMSAE_SRC Datenquelle 20030821
6 Importing I_STDID Call by reference Type reference (TYPE) RMSAE_ID ID des Aufrufers (Formel RECN, ...) 20020902
7 Importing I_VALDAT Call by reference Type reference (TYPE) RMSAE_VALDAT Stichtag 20020902
8 Changing XT_ITEM Call by reference Type reference (TYPE) TABLE Tabelle mit den STD Items 20020902

Method FILL_ADD_DATA on Interface IF_RMSA_STD_DIA has no exception.

Method HANDLE_MESSAGES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_MESSAGES Call by reference Type reference (TYPE) FRMLTY_LOG_REC RMS-FRM: Nachrichten für AnwendungsLog 20021015
2 Importing I_REGARD_SENT_FLAG Call by reference Type reference (TYPE) FRMLE_FLAG Flag, dass message gesendet wurde berücksichtigen 20060322

Method HANDLE_MESSAGES on Interface IF_RMSA_STD_DIA has no exception.

Method OKCODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_OUTTAB Call by reference Type reference (TYPE) TABLE AVL Tabelle 20030923
2 Importing IT_SELECTED_ROWS Call by reference Type reference (TYPE) LVC_T_ROW ALV-Control: markierte Tabellenzeilen 20030923
3 Importing I_OKCODE Call by reference Type reference (TYPE) SYUCOMM Funktionscode 20030923

Method OKCODE on Interface IF_RMSA_STD_DIA has no exception.

Method ON_DATA_CHANGED Signature

Method ON_DATA_CHANGED on Interface IF_RMSA_STD_DIA has no parameter.
Method ON_DATA_CHANGED on Interface IF_RMSA_STD_DIA has no exception.

Method ON_F4_HELP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing XR_EVENT_DATA Call by reference Object reference (TYPE REF TO) CL_ALV_EVENT_DATA Changing Datencontainer für Events 20020917
2 Changing XS_ROW_NO Call by reference Type reference (TYPE) LVC_S_ROID Zuordnung Zeilennummer zu Zeilen-ID 20020917
3 Changing XT_BAD_CELLS Call by reference Type reference (TYPE) LVC_T_MODI ALV Control: Tabelle der geänderten Zellen für Anwendung 20020917
4 Changing X_DISPLAY Call by reference Type reference (TYPE) CHAR01 Charakterfeld der Länge 1 20020917
5 Changing X_FIELDNAME Call by reference Type reference (TYPE) LVC_FNAME ALV-Control: Feldname internes Tabellenfeld 20020917
6 Changing X_FIELDVALUE Call by reference Type reference (TYPE) LVC_VALUE ALV-Control: Zelleninhalt 20020917

Method ON_F4_HELP on Interface IF_RMSA_STD_DIA has no exception.

Method SELECT_STREAM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_ITEM Call by reference Type reference (TYPE) ANY obsolet 20020902
2 Importing IT_ITEM Call by reference Type reference (TYPE) TABLE Komplette Item Tabelle 20020919
3 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20020919
4 Importing I_STDID Call by reference Type reference (TYPE) RMSAE_ID ID des Aufrufers (Formel RECN, ...) 20020919
5 Importing I_VALDAT Call by reference Type reference (TYPE) RMSAE_VALDAT Stichtag 20020919
6 Changing XS_ITEM Call by reference Type reference (TYPE) ANY Daten über selektierten Stream 20020919
# Exception Resumable Description Created on
1 EXC_NO_STREAM Keine Streams vorhanden bzw. kein Stream ausgewählt 20020919
History
Last changed by/on SAP  20060711 
SAP Release Created in 210