SAP ABAP Interface IF_EX_WTY_DYNPRO_DYNAMIC (BAdI Interface IF_EX_WTY_DYNPRO_DYNAMIC)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   LO-WTY (Application Component) Warranty Claim Processing
     ISAUTO_WTY (Package) Warranty Processing
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_DEF_IM_WTY_DYNPRO_DYNAMIC Default Implementation for BAdI Definition WTY_DYNPRO_DYNAM 20020313
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EXM_IM_WTY_DYNPRO_DYNAMIC Sample Implementation for BAdI Definition WTY_DYNPRO_DYNA 20020313
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_WTY_DYNPRO_DYNAMIC BAdI Class CL_EX_WTY_DYNPRO_DYNAMIC 20011127
Properties
Interface IF_EX_WTY_DYNPRO_DYNAMIC  
Short Description BAdI Interface IF_EX_WTY_DYNPRO_DYNAMIC    
General Data
Package ISAUTO_WTY   Warranty Processing 
Created 20011127   SAP 
Last changed 20060711   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PWTY Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_WTY_DYNPRO_DYNAMIC has no interface.
Friends
Interface IF_EX_WTY_DYNPRO_DYNAMIC has no friend.
Attributes
Interface IF_EX_WTY_DYNPRO_DYNAMIC has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHANGE_CLAIM_NAVTREE_STRUCTURE Instance method Public Method Modify Navigation Tree Structure 20020806
2 CHANGE_FIELDCAT_ITEM Instance method Public Method Change Field Catalog Item List 20060330
3 CHANGE_LAYOUT_ITEM Instance method Public Method Change Field Catalog Item List 20060330
4 GET_RELATED_CLAIMS Instance method Public Method List of Related Claims for Navigation Tree 20020313
5 SET_SCREEN Instance method Public Method Set Screens 20011127
Events
Interface IF_EX_WTY_DYNPRO_DYNAMIC has no event.
Types
Interface IF_EX_WTY_DYNPRO_DYNAMIC has no local type.
Method Signatures

Method CHANGE_CLAIM_NAVTREE_STRUCTURE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_WTY_NAVTREE_DATA Call by reference Type reference (TYPE) WTY_NAVTREE_DATA_TAB Tabellentype für Navigationsbaum innere Struktur 20020806
2 Importing IS_PNWTYH Call by reference Type reference (TYPE) WTY_PNWTYH_DIA Garantieantragskopf (PVS-Knoten) 20020806
3 Importing IT_PNWTYV Call by reference Type reference (TYPE) WTY_PNWTYV_DIA_TAB Tabellentype Garantieantragsversion (PVS-Knoten) 20020806

Method CHANGE_CLAIM_NAVTREE_STRUCTURE on Interface IF_EX_WTY_DYNPRO_DYNAMIC has no exception.

Method CHANGE_FIELDCAT_ITEM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_FIELDCAT Call by reference Type reference (TYPE) LVC_T_FCAT Feldkatalog für ListViewerControl 20060330
2 Importing IS_PNH_DYNPRO Call by reference Type reference (TYPE) WTY_PNH_DYNPRO Garantieantrag: Dynproelemente des Antragskopfes 20060330
3 Importing IS_PNV_DYNPRO Call by reference Type reference (TYPE) WTY_PNV_DYNPRO Garantieantrag: Dynproelemente der Antragsversion 20060330
4 Importing IT_PVWTY_ALV Call by reference Type reference (TYPE) PWTY_PVWTY_ALV_T 20060330

Method CHANGE_FIELDCAT_ITEM on Interface IF_EX_WTY_DYNPRO_DYNAMIC has no exception.

Method CHANGE_LAYOUT_ITEM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_LINECOLOR Call by reference Type reference (TYPE) CHAR4 Nicht näher def. Bereich, evtl. für Patchlevels verwendbar 20060330
2 Changing CT_CELLTAB Call by reference Type reference (TYPE) LVC_T_STYL ALV-Control: Styletabelle für Zellen 20060330
3 Changing CT_COLOR Call by reference Type reference (TYPE) LVC_T_SCOL ALV-Control: Tabelle für Zelleneinfärbung 20060330
4 Importing IS_PNH_DYNPRO Call by reference Type reference (TYPE) WTY_PNH_DYNPRO Garantieantrag: Dynproelemente des Antragskopfes 20060330
5 Importing IS_PNV_DYNPRO Call by reference Type reference (TYPE) WTY_PNV_DYNPRO Garantieantrag: Dynproelemente der Antragsversion 20060330
6 Importing IS_PVWTY_ALV Call by reference Type reference (TYPE) PWTY_PVWTY_ALV 20060330

Method CHANGE_LAYOUT_ITEM on Interface IF_EX_WTY_DYNPRO_DYNAMIC has no exception.

Method GET_RELATED_CLAIMS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_TREE_HEADER Call by reference Type reference (TYPE) TV_HEADING Titel des Navigationsbaum 20020805
2 Exporting ET_PNWTYH Call by reference Type reference (TYPE) PNWTYH_TAB Tabelle Garantieantragskopf 20020313
3 Importing IS_PNWTYH Call by reference Type reference (TYPE) PWTY_PNWTYH_LI Kopfdaten des Antrags 20020313
# Exception Resumable Description Created on
1 NO_RELATED_CLAIMS Falls gibt es keine in Verbindung stehende Anträge 20020314

Method SET_SCREEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_ACTION_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Actionbutton Header ersetzen 20021127
2 Changing CV_ACTION_VER_SC Call by reference Type reference (TYPE) SY-DYNNR Actionbutton Version setzen 20021127
3 Changing CV_AUTH_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Authority Daten Header ersetzen 20021127
4 Changing CV_EXTOLD_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Extold subscreen 20021129
5 Changing CV_HEADER_CUSTOMER Call by reference Type reference (TYPE) SY-DYNNR Nummer des Kundenscreen Kopfdaten 20011127
6 Changing CV_HEADER_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Nummer des Dynpros Kopfdaten 20011127
7 Changing CV_INFO_BT_SCREEN Call by reference Type reference (TYPE) SY-DYNNR info button 20021129
8 Changing CV_INFO_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Infoscreen Header 20021129
9 Changing CV_LOAD_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Nummer desDynpros geladener Antrag 20011127
10 Changing CV_MODEL_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Modelscreen Header 20021129
11 Changing CV_OBJECT_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Objekt Bild ausblenden oder ersetzen durch Serialnummerbild 20020809
12 Changing CV_PARTNER_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Partnerdaten Header ersetzen 20021127
13 Changing CV_TREE_SCREEN Call by reference Type reference (TYPE) SY-DYNNR Nicht mehr verwendet ab DIMP47!!! 20020328
14 Importing IS_PNWTYH_DYNPRO Call by reference Type reference (TYPE) WTY_PNH_DYNPRO Garantieantrag: Dynproelemente des Antragskopfes 20011127
15 Importing IS_PNWTYV_DYNPRO Call by reference Type reference (TYPE) WTY_PNV_DYNPRO Garantieantrag: Dynproelemente der Antragsversion 20011127
16 Importing IV_GUI_MODE Call by reference Type reference (TYPE) C Bearbeitungsmodus 'R' - Anzeige 20011127

Method SET_SCREEN on Interface IF_EX_WTY_DYNPRO_DYNAMIC has no exception.
History
Last changed by/on SAP  20060711 
SAP Release Created in 470