SAP ABAP Interface IF_EX_SFWS_QPCP (Interface for BAdI: BADI_SFWS_QPCP)
Hierarchy
☛
SAP_APPL (Software Component) Logistics and Accounting
⤷
QM-PT-IP (Application Component) Inspection Planning
⤷
QPCP_SFWS_SC (Package) QM: Source Text Switch-Package for Insp. Char. Enhancements
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_SFWS_QPCP | Integration of Control Plan Fields in EWB | 20070704 |
Properties
| Interface | IF_EX_SFWS_QPCP | |
| Short Description | Interface for BAdI: BADI_SFWS_QPCP |
General Data
| Package | QPCP_SFWS_SC | QM: Source Text Switch-Package for Insp. Char. Enhancements |
| Created | 20070704 | SAP |
| Last changed | 20100310 | SAP |
| Unicode checks active |
Forward declarations
Interface IF_EX_SFWS_QPCP has no forward declaration.
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20070704 |
Friends
Interface IF_EX_SFWS_QPCP has no friend.
Attributes
Interface IF_EX_SFWS_QPCP has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Adjust "No Inspection" Indicator, If Required | 20070717 | |
| 2 | Instance method | Public | Method | Adjust "No Inspection" Indicator, If Required | 20070717 | |
| 3 | Instance method | Public | Method | Delete "No Inspection" Indicator | 20070717 | |
| 4 | Instance method | Public | Method | Control Fields: Control According to Client Settings | 20070716 | |
| 5 | Instance method | Public | Method | Set Indicator from "No Inspection" to "Not Ready for Input" | 20070717 | |
| 6 | Instance method | Public | Method | Control Fields: Control According to Client Settings | 20070822 |
Events
Interface IF_EX_SFWS_QPCP has no event.
Types
Interface IF_EX_SFWS_QPCP has no local type.
Method Signatures
Method ADJUST_NO_INSPECTION_INDICATOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 | |||
| 2 | IV_ESTUKZ1 | Call by reference | Type reference (TYPE) | QESTU1 | Keine Merkmalserfassung | 20070717 |
Method ADJUST_NO_INSPECTION_INDICATOR on Interface IF_EX_SFWS_QPCP has no exception.
Method ADJUST_NO_INSPECTION_IND_QPAA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 | |||
| 2 | IV_ESTUKZ | Call by reference | Type reference (TYPE) | QESTUKZ | Erfassungsart | 20070717 |
Method ADJUST_NO_INSPECTION_IND_QPAA on Interface IF_EX_SFWS_QPCP has no exception.
Method CLEAR_NO_INSPECTION_INDICATOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 |
Method CLEAR_NO_INSPECTION_INDICATOR on Interface IF_EX_SFWS_QPCP has no exception.
Method FIELD_MODIFICATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CV_SCREEN | Call by reference | Type reference (TYPE) | SCREEN | Strukturbeschreibung für System-Datenobjekt SCREEN | 20070716 | |||
| 2 | IV_ACTYPE | Call by reference | Type reference (TYPE) | C | Aktivität | 20070905 |
Method FIELD_MODIFICATION on Interface IF_EX_SFWS_QPCP has no exception.
Method MAKE_NO_INSPECTION_INACTIVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CV_SCREEN | Call by reference | Type reference (TYPE) | SCREEN | Strukturbeschreibung für System-Datenobjekt SCREEN | 20070717 | |||
| 2 | IV_ESTUKZ | Call by reference | Type reference (TYPE) | CHA_CLASS_DATA-ESTUKZ | Erfassungsart | 20070822 |
Method MAKE_NO_INSPECTION_INACTIVE on Interface IF_EX_SFWS_QPCP has no exception.
Method TABLE_COLUMN_MODIFIATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CV_INVISIBLE | Call by reference | Type reference (TYPE) | CHAR1 | Unsichtbar ? | 20070822 | |||
| 2 | CV_VISLENGTH | Call by reference | Type reference (TYPE) | ICONLENGTH | Ausgabelänge | 20070822 | |||
| 3 | IV_GROUP3 | Call by reference | Type reference (TYPE) | SCREEN-GROUP3 | Screen-Gruppe | 20070824 |
Method TABLE_COLUMN_MODIFIATION on Interface IF_EX_SFWS_QPCP has no exception.
History
| Last changed by/on | SAP | 20100310 |
| SAP Release Created in | 603 |