SAP ABAP Interface IF_EX_ISU_EDM_PROFHEAD (BAdI Interface IF_EX_ISU_EDM_PROFHEAD)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U-EDM (Application Component) Energy Data Management
⤷
EE_EDM_PRO (Package) Profile Management

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_ISU_EDM_PROFHEAD | BAdI Class CL_EX_ISU_EDM_PROFHEAD | 20031124 |
Properties
Interface | IF_EX_ISU_EDM_PROFHEAD | |
Short Description | BAdI Interface IF_EX_ISU_EDM_PROFHEAD |
General Data
Package | EE_EDM_PRO | Profile Management |
Created | 20031124 | SAP |
Last changed | 20050224 | SAP |
Unicode checks active |
Forward declarations
Interface IF_EX_ISU_EDM_PROFHEAD has no forward declaration.
Interfaces
Interface IF_EX_ISU_EDM_PROFHEAD has no interface.
Friends
Interface IF_EX_ISU_EDM_PROFHEAD has no friend.
Attributes
Interface IF_EX_ISU_EDM_PROFHEAD has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Input Check for Additional Data | 20031124 |
2 | ![]() |
Instance method | Public | Method | Data Transport from Screen | 20031124 |
3 | ![]() |
Instance method | Public | Method | Data Transport for Screen | 20031124 |
Events
Interface IF_EX_ISU_EDM_PROFHEAD has no event.
Types
Interface IF_EX_ISU_EDM_PROFHEAD has no local type.
Method Signatures
Method CHECK_INPUT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CI_DATA | Call by reference | Type reference (TYPE) | EPROFHEAD_DYNPRO | Dynprofelder für EDM Profil-Kopfdaten | 20031124 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Eingabefehler | 20031124 |
Method GET_DATA_FROM_SCREEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_CI_DATA | Call by reference | Type reference (TYPE) | EPROFHEAD_CI | CI Includdaten für Profilkopf | 20031124 |
Method GET_DATA_FROM_SCREEN on Interface IF_EX_ISU_EDM_PROFHEAD has no exception.
Method PUT_DATA_TO_SCREEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CI_DATA | Call by reference | Type reference (TYPE) | EPROFHEAD_DYNPRO | CI Includdaten für Profilkopf | 20031124 | ||
2 | ![]() |
IM_WMODE | Call by reference | Type reference (TYPE) | E_MODE | Bearbeitungsmodus (1 = Anzeigen, 2 = Ändern, 3 = Anlegen...) | 20031125 |
Method PUT_DATA_TO_SCREEN on Interface IF_EX_ISU_EDM_PROFHEAD has no exception.
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in | 472 |