SAP ABAP Interface IF_EX_IPPE_PRODVER (BAdI Interface IF_EX_IPPE_PRODVER)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEENV (Package) Decoupling of iPPE Environment
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_IPPE_PRODVER BAdI Class CL_EX_IPPE_PRODVER 20011029
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPEDI_PRODVER BAdI Implementation for IPPE_PRODVER 20020903
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPER3E_PRODVER BAdI Implementation for IPPE_PRODVER 20020107
Properties
Interface IF_EX_IPPE_PRODVER  
Short Description BAdI Interface IF_EX_IPPE_PRODVER    
General Data
Package CPPEENV   Decoupling of iPPE Environment 
Created 20011029   SAP 
Last changed 20041209   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPENV Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_IPPE_PRODVER has no interface.
Friends
Interface IF_EX_IPPE_PRODVER has no friend.
Attributes
Interface IF_EX_IPPE_PRODVER has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CTMENU_ADD Instance method Public Method System-Specific Enhancement of Context Menu 20021108
2 CTMENU_SELECT Instance method Public Method System-Specific Execution of Context Menu Operations 20021108
3 EKG Instance method Public Method Data Analysis and Correction 20011105
4 GET_DDIC_FIELD Instance method Public Method Read the DDIC Field for Production Version 20041104
5 HELP_INFO_CALL Instance method Public Method F1 Help for Name of Production Version 20040827
6 PRODVER_ACTIVE Instance method Public Method Check whether connection to a production version exists 20020116
7 PRODVER_BUFFER_BACKUP Instance method Public Method Save Buffer 20030903
8 PRODVER_BUFFER_REFRESH Instance method Public Method Delete Buffer 20030903
9 PRODVER_BUFFER_RESTORE Instance method Public Method Restore Saved Buffer in Original Buffer 20030903
10 PRODVER_DELETE Instance method Public Method Delete a Production Version 20011029
11 PRODVER_GET_BY_RANGES Instance method Public Method Read the Production Versions By RANGES Tables 20020201
12 PRODVER_KEY_CONVERT Instance method Public Method Reads Internal Production Version Key for PPEGUID 20031008
13 PRODVER_MAINT Instance method Public Method Maintain a Production Version 20011029
14 PRODVER_MODEL_ADD Instance method Public Method Assignment of Model for Production Version 20031008
15 PRODVER_MODEL_DEL Instance method Public Method Delete Model Assignment for Production Version 20031008
16 PRODVER_MODEL_READ Instance method Public Method Reads Assigned Model for Production Version 20030905
17 PRODVER_ORDER_EXISTS Instance method Public Method Check whether orders exist for a production version 20020225
18 PRODVER_READ Instance method Public Method Read a Production Version 20011029
19 PRODVER_READ_MULT Instance method Public Method Read Multiple Production Versions 20030721
20 PRODVER_RTO_ACTIVE Instance method Public Method Checks if PDS Connection Exists 20031015
21 PRODVER_RTO_DISPLAY Instance method Public Method PDS Display 20031015
22 PRODVER_RTO_GEN Instance method Public Method Generate Runtime Objects 20031015
23 PRODVER_RTO_STATUS_GET Instance method Public Method Reads Status of PDS and Corresponding Icon 20031015
24 PRODVER_SAVE Instance method Public Method Save the production versions 20011228
25 PRODVER_TEXT Instance method Public Method Read the texts for the production version 20020208
26 PRODVER_USABLE_FOR_PPE Instance method Public Method Check whether production version can be used for iPPE 20020225
27 VALUE_INFO_CALL Instance method Public Method Search Help for Name of Production Version 20040827
28 VERID_LENGTH Instance method Public Method Length of Name of Production Version 20040827
Events
Interface IF_EX_IPPE_PRODVER has no event.
Types
Interface IF_EX_IPPE_PRODVER has no local type.
Method Signatures

Method CTMENU_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_MENU Call by reference Object reference (TYPE REF TO) CL_CTMENU Context Menu 20031024
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_ADD 20030415
3 Importing IV_MODE Call by reference Type reference (TYPE) C Anzeige/Ändern-Modus 20031024
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE Engine 20031024
5 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID interne Identifikation für PVS Objekte 20031024
# Exception Resumable Description Created on
1 MENU_ADD_ERROR Fehler beim Ergänzen des Kontextmenüs 20031024

Method CTMENU_SELECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_PROCESSED Call by reference Type reference (TYPE) C Operation wurde ausgeführt 20031024
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_SELECT 20030415
3 Importing IV_MODE Call by reference Type reference (TYPE) C Anzeige/Ändern-Modus 20031024
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE-Engine 20031024
5 Importing IV_OKCODE Call by reference Type reference (TYPE) SY-UCOMM Bildschirmbilder, Funktionscode, der PAI ausgelöst hat 20031024
6 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID interne Identifikation für PVS Objekte 20031024
# Exception Resumable Description Created on
1 CTMENU_SELECT_ERROR Fehler beim Ausführen der Operation aus dem Kontextmenü 20031024

Method EKG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode EKG 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20011105
3 Importing IM_REPAIR Call by reference Type reference (TYPE) C PPET_FALSE Activate correction mode 20011105
# Exception Resumable Description Created on
1 PRODVER_EKG_ERROR Error when analyzing and correcting the data 20011105

Method GET_DDIC_FIELD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning EX_DDIC_FIELD Value transfer Type reference (TYPE) CHAR40 DDIC Feld 20041104
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_DDIC_FIELD 20041104
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20041104
# Exception Resumable Description Created on
1 ERROR_GET_DDIC_FIELD Lesefehler bei der Ermittlung des DDIC Feldes 20041104

Method HELP_INFO_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Systemumgebung, in der das iPPE genutzt wird (INS 614180) 20040827
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichten-Handling im iPPE 20040827
3 Importing IV_UI_ID Call by reference Type reference (TYPE) PPENV_UI_ID Rufende Oberfläche 20040827
# Exception Resumable Description Created on
1 ERROR Fehler bei Aufruf der F1-Hilfe 20040827

Method PRODVER_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning EX_PRODVER_ACTIVE Value transfer Type reference (TYPE) XFELD Producion version exists ['X', ' '] 20020116
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ACTIVE 20030415

Method PRODVER_ACTIVE on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_BUFFER_BACKUP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ORDER_EXISTS 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030903

Method PRODVER_BUFFER_BACKUP on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_BUFFER_REFRESH Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ORDER_EXISTS 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030903

Method PRODVER_BUFFER_REFRESH on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_BUFFER_RESTORE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ORDER_EXISTS 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030903

Method PRODVER_BUFFER_RESTORE on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_DELETE 20030415
2 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal Identification of the Component (Material/Product) 20011227
3 Importing IM_LOCID Call by reference Type reference (TYPE) PPE_LOCID Plant/Location in iPPE 20011227
4 Importing IM_LOCID_EMPTY Call by reference Type reference (TYPE) XFELD PPET_FALSE Kennzeichen für leeres Werk 20030930
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011029
6 Importing IM_VERSION Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION Production Version 20011227
# Exception Resumable Description Created on
1 DELETE_ERROR Processing error 20011029

Method PRODVER_GET_BY_RANGES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PRODVER_TAB Call by reference Type reference (TYPE) PPENV_PRODVER_TAB Production Versions 20020201
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_GET_BY_RANGES 20030415
3 Importing IM_CMPID_SEL_TAB Call by reference Type reference (TYPE) PPENV_CMPID_SEL_TAB Components Table 20020201
4 Importing IM_DATE_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_HIGH Ende des Suchzeitraums 20030905
5 Importing IM_DATE_LO Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_LO Beginn des Suchzeitraums 20030905
6 Importing IM_IPPE_ONLY_FLG Call by reference Type reference (TYPE) C Indicator: Only Production Versions with iPPE Data 20020201
7 Importing IM_LOCID_SEL_TAB Call by reference Type reference (TYPE) PPENV_LOCID_SEL_TAB Locations Table 20020201
8 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020201
9 Importing IM_QUANT_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_HIGH Oberer Losgrößenbereich des Suchintervalls 20030905
10 Importing IM_QUANT_LO Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_LO Unterer Losgrößenbereich des Suchintervalls 20030905
11 Importing IM_VERSION_SEL_TAB Call by reference Type reference (TYPE) PPENV_VERSION_SEL_TAB Versions Table 20020201
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20020201

Method PRODVER_KEY_CONVERT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID PPEGUID der Produktionsversion 20031008
2 Exporting EV_VERSION_INT Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION_INT Interner Schlüssel der Produktionsversion 20031008
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031008
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031008
5 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID PPEGUID der Produktionsversion 20031008
6 Importing IV_VERSION_INT Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION_INT Interner Schlüssel der Produktionsversion 20031008

Method PRODVER_KEY_CONVERT on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_MAINT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER Production Version 20011227
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MAINT 20030415
3 Importing IM_LOCID_EMPTY Call by reference Type reference (TYPE) XFELD PPET_FALSE Kennzeichen für leeres Werk 20030930
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011029
# Exception Resumable Description Created on
1 MAINTAIN_ERROR Error maintaining a production version 20011029

Method PRODVER_MODEL_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031008
2 Importing IV_MODEL Call by reference Type reference (TYPE) PPENV_PDV_MODEL-MODEL Modell 20031008
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031008
4 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID PPEGUID der Produktionsversion 20031008
5 Importing IV_VERSION_INT Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION_INT Interner Schlüssel der Produktionsversion 20031013
# Exception Resumable Description Created on
1 ADD_ERROR Fehler beim Hinzufügen 20031013

Method PRODVER_MODEL_DEL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031008
2 Importing IV_MODEL Call by reference Type reference (TYPE) PPENV_PDV_MODEL-MODEL Modell 20031008
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031008
4 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID PPEGUID der Produktionsversion 20031008
5 Importing IV_VERSION_INT Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION_INT Interner Schlüssel der Produktionsversion 20031013
# Exception Resumable Description Created on
1 DELETE_ERROR Fehler beim Löschen 20031013

Method PRODVER_MODEL_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PDV_MODEL Call by reference Type reference (TYPE) PPENV_PDV_MODEL_TAB Der Produktionsversion zugeordnete Modell 20030905
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20030905
3 Importing IV_MODEL Call by reference Type reference (TYPE) PPENV_PDV_MODEL-MODEL Modell 20031008
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030905
5 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID PPEGUID der Produktionsversion 20031008
6 Importing IV_VERSION_INT Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION_INT Interner Schlüssel der Produktionsversion 20031013
7 Importing IV_WITH_DEL Call by reference Type reference (TYPE) XFELD PPET_FALSE Auch Sätze mit Löschkennzeichen 20031013
# Exception Resumable Description Created on
1 INPUT_ERROR Leere Eingabeparameter 20030905

Method PRODVER_ORDER_EXISTS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ORDER_EXISTS Call by reference Type reference (TYPE) C Indicator: Order exists 20020225
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ORDER_EXISTS 20030415
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020404
4 Importing IM_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER Production Version Data 20020225

Method PRODVER_ORDER_EXISTS on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PRODVER_TAB Call by reference Type reference (TYPE) PPENV_PRODVER_TAB Table of Production Versions 20011227
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_READ 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal Identification of the Component (Material/Product) 20011227
4 Importing IM_LOCID Call by reference Type reference (TYPE) PPE_LOCID Plant/Location in iPPE 20011227
5 Importing IM_LOCID_EMPTY Call by reference Type reference (TYPE) XFELD PPET_FALSE Kennzeichen für leeres Werk 20030930
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011029
7 Importing IM_PPEGUID Call by reference Type reference (TYPE) PVS_GUID Internal Identification for PVS Objects 20020205
8 Importing IM_VERSION Call by reference Type reference (TYPE) PPENV_PRODVER-VERSION Production Version 20011227
9 Importing IV_WITH_DEL Call by reference Type reference (TYPE) XFELD PPET_FALSE Auch Sätze mit Löschkennzeichen 20031013
# Exception Resumable Description Created on
1 INPUT_ERROR Wrong Import Parameter 20011227

Method PRODVER_READ_MULT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER_TAB Tabelle der Produktions-Versionen 20030721
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_ORDER_EXISTS 20030721
3 Importing IT_PPEGUID Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle mit int. Schlüsseln von iPPE Einstiegsobjekten 20030721
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030721
5 Importing IV_SYNC_REQ Call by reference Type reference (TYPE) XFELD PPET_TRUE Flag zur Puffer-Synchronisation mit der DB 20030721
6 Importing IV_WITH_DEL Call by reference Type reference (TYPE) XFELD PPET_FALSE Auch Sätze mit Löschkennzeichen 20031013
# Exception Resumable Description Created on
1 INPUT_ERROR fehlerhafte Importing-Parameter 20030721

Method PRODVER_RTO_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RTO_ACTIVE_FLG Call by reference Type reference (TYPE) XFELD Kennzeichen für aktive Laufzeitobjektanbindung 20031015
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031015
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031015

Method PRODVER_RTO_ACTIVE on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_RTO_DISPLAY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031015
2 Importing IT_PPEGUID Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle mit int. Schlüsseln von Laufzeitobjekten 20031015
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031015
# Exception Resumable Description Created on
1 DISPLAY_ERROR Fehler beim Anzeigen 20031015

Method PRODVER_RTO_GEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031015
2 Importing IT_PPEGUID Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle mit int. Schlüsseln von Laufzeitobjekten 20031015
3 Importing IV_DO_SIMULATION Call by reference Type reference (TYPE) XFELD PPET_FALSE Kennzeichen für simulative Generierung 20031015
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031015
# Exception Resumable Description Created on
1 GEN_ERROR Fehler beim Generieren 20031015

Method PRODVER_RTO_STATUS_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_RTO_STATUS Call by reference Type reference (TYPE) PPENV_RTO_STATUS_TAB Status der Laufzeitobjekte und Icons 20031015
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_MODEL_READ 20031015
3 Importing IT_PPEGUID Call by reference Type reference (TYPE) PPET_GUID_TAB Tabelle mit int. Schlüsseln von Laufzeitobjekten 20031015
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031015

Method PRODVER_RTO_STATUS_GET on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_SAVE 20030415
2 Importing IM_COMMIT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Execute Commit ['X', ' '] 20011228
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011228
4 Importing IM_UNLOCK_FLG Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Unlock Production Versions ['X', ' '] 20011228
# Exception Resumable Description Created on
1 SAVE_ERROR Error when saving the production versions 20011228

Method PRODVER_TEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PRODVER_ASS_TYPE_TXT Call by reference Type reference (TYPE) C Description of Access Type 20020208
2 Exporting EX_PRODVER_LENGTH Call by reference Type reference (TYPE) I Länge des Feldes 20030904
3 Exporting EX_PRODVER_PLURAL_TXT Call by reference Type reference (TYPE) C Bezeichung der Produktionsversion (Mehrzahl) 20030903
4 Exporting EX_PRODVER_TXT Call by reference Type reference (TYPE) C Description of Production Version 20020208
5 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_TEXT 20030415

Method PRODVER_TEXT on Interface IF_EX_IPPE_PRODVER has no exception.

Method PRODVER_USABLE_FOR_PPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_USABLE_FOR_PPE 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020308
3 Importing IM_MSG_TYPE Call by reference Type reference (TYPE) C PPET_MSG_TYPE-ERROR Error type for messages [' ', E', 'W', 'I', 'S'] 20020308
4 Importing IM_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER Production Version Data 20020225
# Exception Resumable Description Created on
1 NOT_USABLE_FOR_PPE Unusable for iPPE 20020225

Method VALUE_INFO_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CMPEXT Call by reference Type reference (TYPE) CMPID_EXT Material/Produkt der gewählten Fertigungsversion 20040827
2 Exporting ES_LOCEXT Call by reference Type reference (TYPE) LOCID_EXT Werk/Lokation der gewählten Fertigungsversion 20040827
3 Exporting ES_VEREXT Call by reference Type reference (TYPE) VERID_EXT Name der gewählten Fertigungsversion 20040827
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Systemumgebung, in der das iPPE genutzt wird (INS 614180) 20040827
5 Importing IS_CMPEXT Call by reference Type reference (TYPE) CMPID_EXT Eingabewert für Suchhilfefeld Material/Produkt 20040827
6 Importing IS_LOCEXT Call by reference Type reference (TYPE) LOCID_EXT Eingabewert für Suchhilfefeld Werk/Lokation 20040827
7 Importing IS_VEREXT Call by reference Type reference (TYPE) VERID_EXT Eingabewert für Suchhilfefeld Name der Fertigungsversion 20040827
8 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichten-Handling im iPPE 20040827
9 Importing IV_UI_ID Call by reference Type reference (TYPE) PPENV_UI_ID Rufende Oberfläche 20040827
# Exception Resumable Description Created on
1 ERROR Fehler bei Aufruf der Suchhilfe 20040827

Method VERID_LENGTH Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_VERID_LENGTH Call by reference Type reference (TYPE) I Länge der Externen Bezeichnung der Fertigungsversion 20040827
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode VERID_LENGTH 20040827
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichten-Handling im iPPE 20040827
# Exception Resumable Description Created on
1 ERROR Fehler beim Ermitteln der Feldlänge 20040827
History
Last changed by/on SAP  20041209 
SAP Release Created in 110