SAP ABAP Interface IF_EX_IPPE_HDR (BAdI Interface IF_EX_IPPE_HDR)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEHDR (Package) Access Object for iPPE
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_IPPE_HDR BAdI Class CL_EX_IPPE_HDR 20020305
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPEDI_HDR Imp. Class for BAdI-Imp. IMPL_IPPE_HDR 20020903
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPER3E_HDR Imp. Class for BAdI-Imp. IMPL_IPPE_HDR 20020307
Properties
Interface IF_EX_IPPE_HDR  
Short Description BAdI Interface IF_EX_IPPE_HDR    
General Data
Package CPPEHDR   Access Object for iPPE 
Created 20020305   SAP 
Last changed 20040316   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPENV Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 PPET4 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 SHLP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_IPPE_HDR has no interface.
Friends
Interface IF_EX_IPPE_HDR has no friend.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 CIA_CALLDYNTYPE Instance attribute Public Type reference (TYPE) TEXT4 Type of Calling Screen 20021022
2 CIA_CMPID_SEL_TAB Instance attribute Public Type reference (TYPE) PPENV_CMPID_SEL_TAB Components Table 20030828
3 CIA_DATE_HIGH Instance attribute Public Type reference (TYPE) PPENV_PRODVER-DATE_HIGH Valid to Date 20030828
4 CIA_DATE_LO Instance attribute Public Type reference (TYPE) PPENV_PRODVER-DATE_LO Valid From Date 20030828
5 CIA_DISPLAY_MODE Instance attribute Public Type reference (TYPE) SY-UCOMM Screens, Function Code Triggered by PAI 20020305
6 CIA_DYNP_CNTL_TAB Instance attribute Public Type reference (TYPE) PPET4_DYNP_CNTL_TAB Table for Default Values and Screen Control 20030916
7 CIA_HDR_DYNP Instance attribute Public Type reference (TYPE) HDR_DYNP Subscreen Data Production Version 20020305
8 CIA_LOCID_SEL_TAB Instance attribute Public Type reference (TYPE) PPENV_LOCID_SEL_TAB Locations Table 20030828
9 CIA_PPECOP_DYNP_TAB Instance attribute Public Type reference (TYPE) PPET4_PPECOP_DYNP_TAB Subscreen Data Co-Products 20021009
10 CIA_PRODVER_FLAG Instance attribute Public Type reference (TYPE) XFELD Production Version Indicator 20020305
11 CIA_QUANT_HIGH Instance attribute Public Type reference (TYPE) PPENV_PRODVER-QUANT_HIGH To Lot Size 20030828
12 CIA_QUANT_LO Instance attribute Public Type reference (TYPE) PPENV_PRODVER-QUANT_LO From Lot Size 20030828
13 CIA_SAVE_FLAG Instance attribute Public Type reference (TYPE) XFELD Save Indicator 20020305
14 CIA_TIME_HIGH Instance attribute Public Type reference (TYPE) PPENV_PRODVER-TIME_HIGH Valid Until 20030828
15 CIA_TIME_LO Instance attribute Public Type reference (TYPE) PPENV_PRODVER-TIME_LO Valid From 20030828
16 CIA_VERSION_SEL_TAB Instance attribute Public Type reference (TYPE) PPENV_VERSION_SEL_TAB Versions Table 20030828
Methods
# Method Level Visibility Method type Description Created on
1 CMPID_GET_PROPERTY Instance method Public Method Check Type for Material 20030214
2 CMPID_HEAD_USE Instance method Public Method Replace Material Version with Header Material 20020902
3 CMPID_VERS_CHECK Instance method Public Method Check Access Data Found for Material Version 20020902
4 CMPID_VERS_USE Instance method Public Method Replace Header Material with Material Version 20020902
5 COSTPROFILE_CONVERT Instance method Public Method Convert SNP Cost Profile 20031211
6 GET_PRODVER Instance method Public Method Read Production Versions 20020305
7 HDR_BUFFER_BACKUP Instance method Public Method Save Buffer 20030903
8 HDR_BUFFER_REFRESH Instance method Public Method Delete Buffer 20030903
9 HDR_BUFFER_RESTORE Instance method Public Method Restore Saved Buffer in Original Buffer 20030903
10 HDR_READ Instance method Public Method Read Change Pointer From Buffer 20030915
11 HDR_RTO_GEN Instance method Public Method Generate PDS 20031104
12 HDR_SAVE Instance method Public Method Save Change Pointer 20030903
13 HDR_SYST_DEL_CHECK Instance method Public Method System-Specific Check when Deleting Access Object 20021115
14 HDR_SYST_MAINT_CHECK Instance method Public Method System-Specific Check when Maintaining Access Object 20021115
15 INVALIDATE_REPPOINT_VERSION Instance method Public Method Invalidate Reporting Point 20021115
16 PRODVER_CIF_CREATE_PRODVER Instance method Public Method Create production version using CIF 20020305
17 PRODVER_GET_SUBSCREEN_DATA Instance method Public Method Get the data from the initial screen 20020305
18 PRODVER_NOTIFY_PLANING Instance method Public Method Notification from planning 20020305
19 PRODVER_PUT_SUBSCREEN_DATA Instance method Public Method Transfer the data to the initial screen 20020305
20 RTO_INVALIDATE Instance method Public Method Create Change Pointer 20030903
Events
Interface IF_EX_IPPE_HDR has no event.
Types
Interface IF_EX_IPPE_HDR has no local type.
Method Signatures

Method CMPID_GET_PROPERTY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_VERSIONED Call by reference Type reference (TYPE) XFELD Feld zum Ankreuzen 20030214
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_GET_PROPERTY 20030415
3 Importing IV_OBJID Call by reference Type reference (TYPE) PVS_OBJID Interne Identifikation eines iPPE-Objekts 20030217

Method CMPID_GET_PROPERTY on Interface IF_EX_IPPE_HDR has no exception.

Method CMPID_HEAD_USE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_SHLP Call by reference Type reference (TYPE) SHLP_DESCR_T Einzelne (aktuelle) Suchhilfe 20020902
2 Changing CT_SHLP_TAB Call by reference Type reference (TYPE) SHLP_DESCR_TAB_T Tabelle der elementaren Suchhilfen 20020902
3 Changing CV_OBJID Call by reference Type reference (TYPE) PVS_OBJID 20020902
4 Exporting EV_VERSIONED Call by reference Type reference (TYPE) C 20030219
5 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_HEAD_USE 20030415

Method CMPID_HEAD_USE on Interface IF_EX_IPPE_HDR has no exception.

Method CMPID_VERS_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_HEADER Call by reference Type reference (TYPE) PPET4_V_PPEHDR_TAB Generierte Tabelle zum View V_PPEHDR 20030214
2 Changing CT_PPEHDR_DB Call by reference Type reference (TYPE) PPET4_PPEHDR_TAB 20030214
3 Changing CT_PPEHDR_LI Call by reference Type reference (TYPE) PPET4_PPEHDR_LI_TAB 20030219
4 Changing CT_PPELNK_DB Call by reference Type reference (TYPE) PPET4_PPELNK_TAB 20030214
5 Changing CT_PPELNK_LI Call by reference Type reference (TYPE) PPET4_PPELNK_LI_TAB 20030219
6 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_VERS_CHECK 20030415
7 Importing IV_CMPID Call by reference Type reference (TYPE) PVS_CMPID Interne Identifikation der Komponente (Material/Produkt) 20030214

Method CMPID_VERS_CHECK on Interface IF_EX_IPPE_HDR has no exception.

Method CMPID_VERS_USE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_PPE_HEADER Call by reference Type reference (TYPE) BAPI_PPE_HEADER iPPE / BAPI: Attribute des Einstiegsobjekts 20020902
2 Changing CV_CMPID Call by reference Type reference (TYPE) PVS_CMPID 20030214
3 Changing CV_OBJID Call by reference Type reference (TYPE) PVS_OBJID 20030214
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_VERS_USE 20030415
5 Importing IV_CMPID Call by reference Type reference (TYPE) PVS_CMPID 20030214
6 Importing IV_PPEGUID Call by reference Type reference (TYPE) PVS_GUID interne Identifikation für PVS Objekte 20030217

Method CMPID_VERS_USE on Interface IF_EX_IPPE_HDR has no exception.

Method COSTPROFILE_CONVERT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_COSTPROFILE_EXT Call by reference Type reference (TYPE) PPE_COSTPROFILE_EXT Externe Bezeichnung für das Kostenprofil für SNP 20031211
2 Exporting EV_COSTPROFILE Call by reference Type reference (TYPE) PPE_PCOST_PROFILE Kostenprofil 20031211
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode COSTPROFILE_CONVERT 20031211
4 Importing IS_COSTPROFILE_EXT Call by reference Type reference (TYPE) PPE_COSTPROFILE_EXT Externe Bezeichnung für das Kostenprofil für SNP 20031211
5 Importing IV_COSTPROFILE Call by reference Type reference (TYPE) PPE_PCOST_PROFILE Kostenprofil 20031211
6 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20031211
# Exception Resumable Description Created on
1 INPUT_ERROR Fehlerhafte Eingabedaten 20031211
2 NOT_FOUND Konvertierung lieferte kein Ergebnis 20031211

Method GET_PRODVER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER 20020305
2 Exporting ET_PRODVER Call by reference Type reference (TYPE) PPENV_PRODVER_TAB 20020305
3 Exporting EV_SUBRC Call by reference Type reference (TYPE) SY-SUBRC Return Value, Return Value After ABAP Statements 20020305
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_PRODVER 20030415
5 Importing IS_EXT_PAR Call by reference Type reference (TYPE) PPET4_PPEHDR_EXT 20020305
6 Importing IT_CMPLOC Call by reference Type reference (TYPE) PPET4_CMPLOC_SYS_TAB Bitte nicht mehr verwenden!!! 20020305
7 Importing IT_CMPLOC_INT Call by reference Type reference (TYPE) PPET4_CMPLOC_INT_TAB 20021015
8 Importing IT_PPEGUID Call by reference Type reference (TYPE) PPET_GUID_TAB 20020305
9 Importing IV_DATE Call by reference Type reference (TYPE) SY-DATUM Return Value, Return Value After ABAP Statements 20020305
10 Importing IV_DATE_TO Call by reference Type reference (TYPE) SY-DATUM Date and Time, Current (Application Server) Date 20020305
11 Importing IV_LOTSIZE Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_LO 20020305
12 Importing IV_LOTSIZE_TO Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_HIGH 20020305
13 Importing IV_MODEL Call by reference Type reference (TYPE) PPET4_MODEL 20020305
14 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT 20020305

Method GET_PRODVER on Interface IF_EX_IPPE_HDR has no exception.

Method HDR_BUFFER_BACKUP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030903

Method HDR_BUFFER_BACKUP on Interface IF_EX_IPPE_HDR has no exception.

Method HDR_BUFFER_REFRESH Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030903

Method HDR_BUFFER_REFRESH on Interface IF_EX_IPPE_HDR has no exception.

Method HDR_BUFFER_RESTORE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030903

Method HDR_BUFFER_RESTORE on Interface IF_EX_IPPE_HDR has no exception.

Method HDR_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PPEGUID Call by reference Type reference (TYPE) PPET4_PPEGUID_TAB Einstiegsobjekte mit Änderungszeigern aus dem Puffer 20030915
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030915
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030915

Method HDR_READ on Interface IF_EX_IPPE_HDR has no exception.

Method HDR_RTO_GEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20031104
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20031104
# Exception Resumable Description Created on
1 AFTER_SAVE_ERROR Fehler beim Zeitpunkt AFTER_SAVE 20031104

Method HDR_SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030903
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030903
# Exception Resumable Description Created on
1 SAVE_ERROR Fehler beim Speichern 20030903

Method HDR_SYST_DEL_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode HDR_SYST_DEL_CHECK 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20021115
3 Importing IM_PPEHDR_S Call by reference Type reference (TYPE) PPET4_PPEHDR_LI Einstiegsstruktur 20021115
# Exception Resumable Description Created on
1 SYST_CHECK_ERROR Systemspezifische Prüfung fehlgeschlagen 20021115

Method HDR_SYST_MAINT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode HDR_SYST_MAINT_CHECK 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20021115
3 Importing IM_PPECOP_TAB Call by reference Type reference (TYPE) PPET4_PPECOP_MAINT_TAB Kuppelproduktsätze 20031015
4 Importing IM_PPEHDR_S Call by reference Type reference (TYPE) PPET4_PPEHDR_LI Einstiegsstruktur 20021115
5 Importing IM_PPEOBJ_TAB Call by reference Type reference (TYPE) PPET4_PPEOBJ_MAINT_TAB Objektsätze 20031015
6 Importing IM_PRODVER_S Call by reference Type reference (TYPE) PPENV_PRODVER Fertigungsversion 20031015
# Exception Resumable Description Created on
1 SYST_CHECK_ERROR Systemspezifische Prüfung fehlgeschlagen 20021115

Method INVALIDATE_REPPOINT_VERSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030415
2 Importing IM_APPLOBJ_TYPE Call by reference Type reference (TYPE) PPET4_PPEOBJ_LI-APPLOBJ_TYPE Rufendes Anwendungsobjekt 20021115
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20021115
4 Importing IM_PPEHDR_TAB Call by reference Type reference (TYPE) PPET4_PPEHDR_LI_TAB Tabelle mit iPPE Einstiegssätzen 20021115
# Exception Resumable Description Created on
1 INVALIDATION_ERROR Fehler bei der Zählpunktinvalidierung 20021115

Method PRODVER_CIF_CREATE_PRODVER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_SUBRC Call by reference Type reference (TYPE) SY-SUBRC Return Code 20020305
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_CIF_CREATE_PRODVER 20030415
3 Importing IM_MSG_HANDLING Call by reference Type reference (TYPE) PPET_MSG_OPT 'N' Option for error messages 20020305
4 Importing IM_PPEHDR Call by reference Type reference (TYPE) BAPI_PPE_HEADER Entry Structure 20020305
5 Importing IM_PRODVER_DATA Call by reference Type reference (TYPE) PPE_PRODVERSION Production Version Data 20020305

Method PRODVER_CIF_CREATE_PRODVER on Interface IF_EX_IPPE_HDR has no exception.

Method PRODVER_GET_SUBSCREEN_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CALLDYNTYPE Call by reference Type reference (TYPE) TEXT4 Typ des rufenden Dynpros 20021022
2 Exporting EX_CMPID_SEL_TAB Call by reference Type reference (TYPE) PPENV_CMPID_SEL_TAB Komponenten-Tabelle 20030828
3 Exporting EX_DATE_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_HIGH Gültig bis Datum 20030828
4 Exporting EX_DATE_LO Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_LO Gültig ab Datum 20030828
5 Exporting EX_DISPLAY_MODE Call by reference Type reference (TYPE) SY-UCOMM Screens, Function Code Triggered by PAI 20020305
6 Exporting EX_DYNP_CNTL_TAB Call by reference Type reference (TYPE) PPET4_DYNP_CNTL_TAB Tabelle für Defaultwerte und Dynprosteuerung 20030916
7 Exporting EX_HDR_DYNP Call by reference Type reference (TYPE) HDR_DYNP Subscreen Data 20020305
8 Exporting EX_LOCID_SEL_TAB Call by reference Type reference (TYPE) PPENV_LOCID_SEL_TAB Lokations-Tabelle 20030828
9 Exporting EX_PPECOP_DYNP_TAB Call by reference Type reference (TYPE) PPET4_PPECOP_DYNP_TAB Subscreen Daten Kuppelprodukte 20021009
10 Exporting EX_PRODVER_FLAG Call by reference Type reference (TYPE) XFELD Production Version Indicator 20020305
11 Exporting EX_QUANT_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_HIGH Losgröße bis 20030828
12 Exporting EX_QUANT_LO Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_LO Losgröße von 20030828
13 Exporting EX_SAVE_FLAG Call by reference Type reference (TYPE) XFELD Save Indicator 20020305
14 Exporting EX_TIME_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-TIME_HIGH Gültig bis Zeit 20030828
15 Exporting EX_TIME_LO Call by reference Type reference (TYPE) PPENV_PRODVER-TIME_LO Gültig ab Zeit 20030828
16 Exporting EX_VERSION_SEL_TAB Call by reference Type reference (TYPE) PPENV_VERSION_SEL_TAB Version-Tabelle 20030828
17 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_GET_SUBSCREEN_DATA 20030415

Method PRODVER_GET_SUBSCREEN_DATA on Interface IF_EX_IPPE_HDR has no exception.

Method PRODVER_NOTIFY_PLANING Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_NOTIFY_PLANING 20030415
2 Importing IM_PPEHDR_TAB Call by reference Type reference (TYPE) PPET4_PPEHDR_TAB Initial table 20020305
# Exception Resumable Description Created on
1 PLANING_ERROR Error in planning 20020305

Method PRODVER_PUT_SUBSCREEN_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PRODVER_PUT_SUBSCREEN_DATA 20030415
2 Importing IM_CALLDYNTYPE Call by reference Type reference (TYPE) TEXT4 Typ des rufenden Dynpros 20021022
3 Importing IM_CMPID_SEL_TAB Call by reference Type reference (TYPE) PPENV_CMPID_SEL_TAB Komponenten-Tabelle 20030828
4 Importing IM_DATE_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_HIGH Gültig bis Datum 20030828
5 Importing IM_DATE_LO Call by reference Type reference (TYPE) PPENV_PRODVER-DATE_LO Gültig ab Datum 20030828
6 Importing IM_DISPLAY_MODE Call by reference Type reference (TYPE) SY-UCOMM Screens, Function Code Triggered by PAI 20020305
7 Importing IM_DYNP_CNTL_TAB Call by reference Type reference (TYPE) PPET4_DYNP_CNTL_TAB Tabelle für Defaultwerte und Dynprosteuerung 20030916
8 Importing IM_HDR_DYNP Call by reference Type reference (TYPE) HDR_DYNP Subscreen Data 20020305
9 Importing IM_LOCID_SEL_TAB Call by reference Type reference (TYPE) PPENV_LOCID_SEL_TAB Lokations-Tabelle 20030828
10 Importing IM_PPECOP_DYNP_TAB Call by reference Type reference (TYPE) PPET4_PPECOP_DYNP_TAB Subscreen Daten Kuppelprodukte 20021009
11 Importing IM_PRODVER_FLAG Call by reference Type reference (TYPE) XFELD Production Version Indicator 20020305
12 Importing IM_QUANT_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_HIGH Losgröße bis 20030828
13 Importing IM_QUANT_LO Call by reference Type reference (TYPE) PPENV_PRODVER-QUANT_LO Losgröße von 20030828
14 Importing IM_SAVE_FLAG Call by reference Type reference (TYPE) XFELD Save Indicator 20020305
15 Importing IM_TIME_HIGH Call by reference Type reference (TYPE) PPENV_PRODVER-TIME_HIGH Gültig bis Zeit 20030828
16 Importing IM_TIME_LO Call by reference Type reference (TYPE) PPENV_PRODVER-TIME_LO Gültig ab Zeit 20030828
17 Importing IM_VERSION_SEL_TAB Call by reference Type reference (TYPE) PPENV_VERSION_SEL_TAB Version-Tabelle 20030828

Method PRODVER_PUT_SUBSCREEN_DATA on Interface IF_EX_IPPE_HDR has no exception.

Method RTO_INVALIDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode INVALIDATE_REPPOINT_VERSION 20030903
2 Importing IT_PPEHDR Call by reference Type reference (TYPE) PPET4_PPEHDR_LI_TAB IPPE-Einstiegsobjekte 20030903
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Art der Meldungsbearbeitung 20030903
4 Importing IV_REMOVE_FLG Call by reference Type reference (TYPE) XFELD PPET_FALSE Löscht Einstiegsobjekte aus den Puffertabellen 20031215
# Exception Resumable Description Created on
1 INVALIDATE_ERROR Fehler bei der Erzeugung von Änderungszeigern 20030903
History
Last changed by/on SAP  20040316 
SAP Release Created in 110