SAP ABAP Interface IF_EX_IPPE_EXPLFLO (BAdI Interface IF_EX_IPPE_EXPLFLO)
Hierarchy
☛
EA-IPPE (Software Component) SAP iPPE
⤷
AP-PPE (Application Component) Integrated Product and Process Engineering
⤷
CPPEEXPLFLO (Package) Line Structure Explosion
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_IPPE_EXPLFLO | BAdI Class CL_EX_IPPE_EXPLFLO | 20020213 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_PPEDI_EXPLFLO | Imp. Class for BAdI-Imp. IMPL_IPPE_EXPLFLO | 20020903 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_PPER3E_EXPLFLO | Imp. Class for BAdI-Imp. IMPL_IPPE_EXPLFLO | 20020213 |
Properties
| Interface | IF_EX_IPPE_EXPLFLO | |
| Short Description | BAdI Interface IF_EX_IPPE_EXPLFLO |
General Data
| Package | CPPEEXPLFLO | Line Structure Explosion |
| Created | 20020213 | SAP |
| Last changed | 20110810 | SAP |
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | PPELX | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 2 | PPET | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 3 | PPET4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 4 | PPET8 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_EX_IPPE_EXPLFLO has no interface.
Friends
Interface IF_EX_IPPE_EXPLFLO has no friend.
Attributes
Interface IF_EX_IPPE_EXPLFLO has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Explosion Runtime Object for Production Lines | 20020213 | |
| 2 | Instance method | Public | Method | Determine Takt Time From Line Resource | 20030915 |
Events
Interface IF_EX_IPPE_EXPLFLO has no event.
Types
Interface IF_EX_IPPE_EXPLFLO has no local type.
Method Signatures
Method EXPLODE_RTOBJ Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CH_ADD_RESULTS | Call by reference | Type reference (TYPE) | PPET8_ADD_RESULTS | Additional Runtime Object Data | 20020213 | |||
| 2 | CH_RESULT_TAB | Call by reference | Type reference (TYPE) | PPET8_RESULT_TAB | Exploded BOMs | 20020213 | |||
| 3 | CS_EXPL_ERROR | Call by reference | Type reference (TYPE) | PPET8_OBJ_MESSAGE | Fehlermeldungen | 20031014 | |||
| 4 | EX_RTO_ALLOC_PHANTOM | Call by reference | Type reference (TYPE) | PPET8_RTO_ALLOC_PHANTOM_TAB | 20021114 | ||||
| 5 | FLT_VAL | Value transfer | Type reference (TYPE) | PPE_ENVIRONMENT | Parameter FLT_VAL der Methode EXPLODE_RTOBJ | 20030415 | |||
| 6 | IM_ALLOC_PHANTOM | Call by reference | Type reference (TYPE) | PPET8_ALLOC_PHANTOM_TAB | 20021112 | ||||
| 7 | IM_DATE | Call by reference | Type reference (TYPE) | D | Explosion Data | 20020213 | |||
| 8 | IM_EXPL_TYPE | Call by reference | Type reference (TYPE) | C | Exp. category | 20020213 | |||
| 9 | IM_MPS | Call by reference | Type reference (TYPE) | C | RPM Performanceschalter | 20040706 | |||
| 10 | IM_MSG_CONTEXT | Call by reference | Type reference (TYPE) | PPE_MSG_CONTEXT | Anwendungskontext einer Meldung | 20031014 | |||
| 11 | IM_MSG_OPT | Call by reference | Type reference (TYPE) | PPET_MSG_OPT | PPET_MSG_OPTIONS-DO_NONE | Message handling | 20020213 | ||
| 12 | IM_OBJGUID | Call by reference | Type reference (TYPE) | PPET_GUID | Line Object | 20020213 | |||
| 13 | IM_OBJID | Call by reference | Type reference (TYPE) | PVS_OBJID | Interne Identifikation eines iPPE-Objekts | 20030916 | |||
| 14 | IM_PLNRPM_TAB | Call by reference | Type reference (TYPE) | PPET_GUID_TAB | Teilliniennetze RPM-Einschränkung | 20030218 | |||
| 15 | IM_PPEGUID | Call by reference | Type reference (TYPE) | PPET4_PPEHDR-PPEGUID | 20100423 | ||||
| 16 | IM_WITH_ACTION_POINTS | Call by reference | Type reference (TYPE) | C | Ermittlung der Aktionspunkte | 20030918 |
Method EXPLODE_RTOBJ on Interface IF_EX_IPPE_EXPLFLO has no exception.
Method GET_LRES_TAKT_TIME Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_TAKT_TIME | Call by reference | Type reference (TYPE) | F | Taktzeit | 20030915 | |||
| 2 | FLT_VAL | Value transfer | Type reference (TYPE) | PPE_ENVIRONMENT | Parameter FLT_VAL der Methode GET_LRES_TAKT_TIME | 20030915 | |||
| 3 | IR_PLANRES_INST | Call by reference | Object reference (TYPE REF TO) | IF_EX_IPPE_PLANRES | BAdI-Interface IF_EX_IPPE_PLANRES | 20030915 | |||
| 4 | IV_OBJID | Call by reference | Type reference (TYPE) | PVS_OBJID | Output-Produkt/ | 20030916 | |||
| 5 | IV_RESUID | Call by reference | Type reference (TYPE) | PPE_RESUID | Interner Schlüssel (GUID) einer Ressource | 20030915 | |||
| 6 | IV_SAPCODE_SEC | Call by reference | Type reference (TYPE) | T006-MSEHI | Maßeinheit | 20030916 |
Method GET_LRES_TAKT_TIME on Interface IF_EX_IPPE_EXPLFLO has no exception.
History
| Last changed by/on | SAP | 20110810 |
| SAP Release Created in | 110 |