SAP ABAP Interface IF_EX_IPPE_EXPLFLO (BAdI Interface IF_EX_IPPE_EXPLFLO)
Hierarchy
☛
EA-IPPE (Software Component) SAP iPPE
⤷
AP-PPE (Application Component) Integrated Product and Process Engineering
⤷
CPPEEXPLFLO (Package) Line Structure Explosion

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_IPPE_EXPLFLO | BAdI Class CL_EX_IPPE_EXPLFLO | 20020213 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_PPEDI_EXPLFLO | Imp. Class for BAdI-Imp. IMPL_IPPE_EXPLFLO | 20020903 |
3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_PPER3E_EXPLFLO | Imp. Class for BAdI-Imp. IMPL_IPPE_EXPLFLO | 20020213 |
Properties
Interface | IF_EX_IPPE_EXPLFLO | |
Short Description | BAdI Interface IF_EX_IPPE_EXPLFLO |
General Data
Package | CPPEEXPLFLO | Line Structure Explosion |
Created | 20020213 | SAP |
Last changed | 20110810 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | PPELX | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | PPET | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | PPET4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | PPET8 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_EX_IPPE_EXPLFLO has no interface.
Friends
Interface IF_EX_IPPE_EXPLFLO has no friend.
Attributes
Interface IF_EX_IPPE_EXPLFLO has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Explosion Runtime Object for Production Lines | 20020213 |
2 | ![]() |
Instance method | Public | Method | Determine Takt Time From Line Resource | 20030915 |
Events
Interface IF_EX_IPPE_EXPLFLO has no event.
Types
Interface IF_EX_IPPE_EXPLFLO has no local type.
Method Signatures
Method EXPLODE_RTOBJ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_ADD_RESULTS | Call by reference | Type reference (TYPE) | PPET8_ADD_RESULTS | Additional Runtime Object Data | 20020213 | ||
2 | ![]() |
CH_RESULT_TAB | Call by reference | Type reference (TYPE) | PPET8_RESULT_TAB | Exploded BOMs | 20020213 | ||
3 | ![]() |
CS_EXPL_ERROR | Call by reference | Type reference (TYPE) | PPET8_OBJ_MESSAGE | Fehlermeldungen | 20031014 | ||
4 | ![]() |
EX_RTO_ALLOC_PHANTOM | Call by reference | Type reference (TYPE) | PPET8_RTO_ALLOC_PHANTOM_TAB | 20021114 | |||
5 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | PPE_ENVIRONMENT | Parameter FLT_VAL der Methode EXPLODE_RTOBJ | 20030415 | ||
6 | ![]() |
IM_ALLOC_PHANTOM | Call by reference | Type reference (TYPE) | PPET8_ALLOC_PHANTOM_TAB | 20021112 | |||
7 | ![]() |
IM_DATE | Call by reference | Type reference (TYPE) | D | Explosion Data | 20020213 | ||
8 | ![]() |
IM_EXPL_TYPE | Call by reference | Type reference (TYPE) | C | Exp. category | 20020213 | ||
9 | ![]() |
IM_MPS | Call by reference | Type reference (TYPE) | C | RPM Performanceschalter | 20040706 | ||
10 | ![]() |
IM_MSG_CONTEXT | Call by reference | Type reference (TYPE) | PPE_MSG_CONTEXT | Anwendungskontext einer Meldung | 20031014 | ||
11 | ![]() |
IM_MSG_OPT | Call by reference | Type reference (TYPE) | PPET_MSG_OPT | PPET_MSG_OPTIONS-DO_NONE | Message handling | 20020213 | |
12 | ![]() |
IM_OBJGUID | Call by reference | Type reference (TYPE) | PPET_GUID | Line Object | 20020213 | ||
13 | ![]() |
IM_OBJID | Call by reference | Type reference (TYPE) | PVS_OBJID | Interne Identifikation eines iPPE-Objekts | 20030916 | ||
14 | ![]() |
IM_PLNRPM_TAB | Call by reference | Type reference (TYPE) | PPET_GUID_TAB | Teilliniennetze RPM-Einschränkung | 20030218 | ||
15 | ![]() |
IM_PPEGUID | Call by reference | Type reference (TYPE) | PPET4_PPEHDR-PPEGUID | 20100423 | |||
16 | ![]() |
IM_WITH_ACTION_POINTS | Call by reference | Type reference (TYPE) | C | Ermittlung der Aktionspunkte | 20030918 |
Method EXPLODE_RTOBJ on Interface IF_EX_IPPE_EXPLFLO has no exception.
Method GET_LRES_TAKT_TIME Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_TAKT_TIME | Call by reference | Type reference (TYPE) | F | Taktzeit | 20030915 | ||
2 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | PPE_ENVIRONMENT | Parameter FLT_VAL der Methode GET_LRES_TAKT_TIME | 20030915 | ||
3 | ![]() |
IR_PLANRES_INST | Call by reference | Object reference (TYPE REF TO) | IF_EX_IPPE_PLANRES | BAdI-Interface IF_EX_IPPE_PLANRES | 20030915 | ||
4 | ![]() |
IV_OBJID | Call by reference | Type reference (TYPE) | PVS_OBJID | Output-Produkt/ | 20030916 | ||
5 | ![]() |
IV_RESUID | Call by reference | Type reference (TYPE) | PPE_RESUID | Interner Schlüssel (GUID) einer Ressource | 20030915 | ||
6 | ![]() |
IV_SAPCODE_SEC | Call by reference | Type reference (TYPE) | T006-MSEHI | Maßeinheit | 20030916 |
Method GET_LRES_TAKT_TIME on Interface IF_EX_IPPE_EXPLFLO has no exception.
History
Last changed by/on | SAP | 20110810 |
SAP Release Created in | 110 |