SAP ABAP Interface IF_EX_IPPE_COL_CHECK_SYST (BAdI Interface IF_EX_IPPE_CMP_CHECK_SYST)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPECMP_APPL (Package) Application Logic of Application Object CMP
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_IPPE_COL_CHECK_SYST BAdI Class CL_EX_IPPE_COL_CHECK_SYST 20050307
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPER3ECOL_SYST Imp. Class for BAdI Imp. IMPL_COL_CHECK_SYST 20050201
Properties
Interface IF_EX_IPPE_COL_CHECK_SYST  
Short Description BAdI Interface IF_EX_IPPE_CMP_CHECK_SYST    
General Data
Package CPPECMP_APPL   Application Logic of Application Object CMP 
Created 20050120   SAP 
Last changed 20050615   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 PPET5 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_IPPE_COL_CHECK_SYST has no interface.
Friends
Interface IF_EX_IPPE_COL_CHECK_SYST has no friend.
Attributes
Interface IF_EX_IPPE_COL_CHECK_SYST has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 PNCOL_DELETE_CHECK Instance method Public Method System-Specific Check Before Deleting COL Node 20050120
2 PNCOL_MAINT_CHECK Instance method Public Method System-Specific Check of COL Application Data of Node 20050120
3 PNODID_MAINT_CHECK Instance method Public Method System-Specific Check of COL Node ID 20050126
4 POSVID_MAINT_CHECK Instance method Public Method System-Specific Check of COL Variant ID 20050126
5 PVCOL_AENNR_CHANGE_CHECK Instance method Public Method System-Specific Check Before Change Number Swap at Variant 20050120
6 PVCOL_DELETE_CHECK Instance method Public Method System-Specific Check Before Deleting COL Variant 20050120
7 PVCOL_MAINT_CHECK Instance method Public Method System-Specific Check of COL Application Data of Variant 20050120
8 PXCOL_ASSIGN_GET Instance method Public Method Read Object Assignments (System-Specific) 20050601
Events
Interface IF_EX_IPPE_COL_CHECK_SYST has no event.
Types
Interface IF_EX_IPPE_COL_CHECK_SYST has no local type.
Method Signatures

Method PNCOL_DELETE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050120
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PNCOL_DELETE_CHECK 20050120
3 Importing IS_PNCOL Call by reference Type reference (TYPE) PPET5_PNCOL_LI Anwendungsdaten Knoten 20050120
4 Importing IS_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI ID-Satz des Knotens 20050120
5 Importing IS_PNTYPE Call by reference Type reference (TYPE) PPET_PNTYPE iPPE-Objekttyp 20050120
6 Importing IV_PNDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050120
7 Importing IV_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT Externer Bezeichner des Knotens 20050120
8 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20050120

Method PNCOL_DELETE_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PNCOL_MAINT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_PNCOL Call by reference Type reference (TYPE) PPET5_PNCOL_LI Anwendungsdaten Knoten 20050120
2 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050120
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PNCOL_MAINT_CHECK 20050120
4 Importing IS_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext 20050120
5 Importing IS_MASTER Call by reference Type reference (TYPE) PPET_AENNR Änderungsnummer 20050120
6 Importing IS_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI ID-Satz des Knotens 20050120
7 Importing IS_PNTYPE Call by reference Type reference (TYPE) PPET_PNTYPE iPPE-Objekttyp 20050120
8 Importing IV_EXISTS Call by reference Type reference (TYPE) C Flag: Knoten existiert ['X', ' '] 20050120
9 Importing IV_PNDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050120
10 Importing IV_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT Externer Bezeichner des Knotens 20050120
11 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20050120

Method PNCOL_MAINT_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PNODID_MAINT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050126
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Systemumgebung, in der das iPPE genutzt wird (INS 614180) 20050126
3 Importing IS_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext 20050126
4 Importing IS_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Identifikation des Knotens 20050126
5 Importing IS_PNODID_OLD Call by reference Type reference (TYPE) PPET_PNODID_LI Identifikation des Knotens 20050126
6 Importing IV_PNDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050126
7 Importing IV_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT externe Identifikation des Knotens 20050126

Method PNODID_MAINT_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method POSVID_MAINT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050126
2 Importing FLT_VAL Call by reference Type reference (TYPE) PPE_ENVIRONMENT Systemumgebung, in der das iPPE genutzt wird (INS 614180) 20050126
3 Importing IS_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext 20050126
4 Importing IS_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Identifikation der Variante 20050126
5 Importing IS_POSVID_OLD Call by reference Type reference (TYPE) PPET_POSVID_LI Identifikation der Variante 20050126
6 Importing IV_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT externe Identifikation der Variante 20050126
7 Importing IV_PVDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050126

Method POSVID_MAINT_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PVCOL_AENNR_CHANGE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050120
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PVCOL_AENNR_CHANGE_CHECK 20050120
3 Importing IS_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext 20050120
4 Importing IS_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI ID-Satz der Variante 20050120
5 Importing IS_PVTYPE Call by reference Type reference (TYPE) PPET_PVTYPE iPPE-Objekttyp 20050120
6 Importing IV_AENNR_NEW Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer im iPPE 20050120
7 Importing IV_AENNR_OLD Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer im iPPE 20050120
8 Importing IV_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT Externer Bezeichner der Variante 20050120
9 Importing IV_PVDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050120
10 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20050120

Method PVCOL_AENNR_CHANGE_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PVCOL_DELETE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050120
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PVCOL_DELETE_CHECK 20050120
3 Importing IS_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI ID-Satz der Variante 20050120
4 Importing IS_PVCOL Call by reference Type reference (TYPE) PPET5_PVCOL_LI Basisdaten 20050120
5 Importing IS_PVTYPE Call by reference Type reference (TYPE) PPET_PVTYPE iPPE-Objekttyp 20050120
6 Importing IV_AENNR Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer im iPPE 20050120
7 Importing IV_DEL_NOHIST Call by reference Type reference (TYPE) C Flag: Nichthistorisch löschen ['X', ' '] 20050120
8 Importing IV_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT Externer Bezeichner der Variante 20050120
9 Importing IV_PVDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050120
10 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20050120

Method PVCOL_DELETE_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PVCOL_MAINT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_PVCOL Call by reference Type reference (TYPE) PPET5_PVCOL_LI Basisdaten 20050120
2 Changing CT_MSG Call by reference Type reference (TYPE) PPET_BALMI_TAB Meldungen 20050120
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PVCOL_MAINT_CHECK 20050120
4 Importing IS_CONTEXT Call by reference Type reference (TYPE) PPET_CONTEXT Kontext 20050120
5 Importing IS_MASTER Call by reference Type reference (TYPE) PPET_AENNR Änderungsnummer 20050120
6 Importing IS_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI ID-Satz der Variante 20050120
7 Importing IS_PVTYPE Call by reference Type reference (TYPE) PPET_PVTYPE iPPE-Objekttyp 20050120
8 Importing IV_AENNR Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer 20050120
9 Importing IV_CUOBJ_FLG Call by reference Type reference (TYPE) C Flag: Konfiguration pflegen ['X', ' '] 20050203
10 Importing IV_EXISTS Call by reference Type reference (TYPE) C Flag: Variante existiert ['X', ' '] 20050120
11 Importing IV_KNOBJ_FLG Call by reference Type reference (TYPE) C Flag: Beziehungswissen pflegen ['X', ' '] 20050203
12 Importing IV_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT Externer Bezeichner der Variante 20050120
13 Importing IV_PVDESC Call by reference Type reference (TYPE) PVS_DESC Bezeichnung iPPE-Objekttyp 20050120
14 Importing IV_SENDER Call by reference Type reference (TYPE) PPET_SENDER Aufrufer 20050120

Method PVCOL_MAINT_CHECK on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.

Method PXCOL_ASSIGN_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_RLMFW Call by reference Type reference (TYPE) XFELD Zuordnung zu Freigabeauftrag 20050601
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PXCMP_ASSIGN_GET 20050601
3 Importing IS_GUID Call by reference Type reference (TYPE) PPET_GUID_AENNR Änderungsstand des Objektes 20050601
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenhandling im iPPE 20050601

Method PXCOL_ASSIGN_GET on Interface IF_EX_IPPE_COL_CHECK_SYST has no exception.
History
Last changed by/on SAP  20050615 
SAP Release Created in 400