SAP ABAP Interface IF_EX_IPPE_CMPID (BAdI Interface IF_EX_IPPE_CMPID)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEENV (Package) Decoupling of iPPE Environment
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_IPPE_CMPID BAdI Class CL_EX_IPPE_CMPID 20010802
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPEDI_CMPID BAdI Implementation for IPPE_CMPID 20020903
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPER3E_CMPID BAdI Implementation for IPPE_CMPID 20010802
Properties
Interface IF_EX_IPPE_CMPID  
Short Description BAdI Interface IF_EX_IPPE_CMPID    
General Data
Package CPPEENV   Decoupling of iPPE Environment 
Created 20010802   SAP 
Last changed 20050220   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPENV Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_IPPE_CMPID has no interface.
Friends
Interface IF_EX_IPPE_CMPID has no friend.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 CMPEXT_FNAME Instance attribute Public Type reference (TYPE) CHAR30 Name of CMPEXT Field 20021002
2 VERSION Constant Public Type reference (TYPE) CHAR1 1 Version 20010808
3 VERSION_HEAD Constant Public Type reference (TYPE) CHAR1 2 Header of a version 20010808
Methods
# Method Level Visibility Method type Description Created on
1 CALL Instance method Public Method Call up Display/Maintenance Transaction 20011022
2 CALL_CMPID_FROM_SCREEN Instance method Public Method Display/Maintenance of Component from Screen 20011023
3 CHECK_BOM_DECOMPOSITION Instance method Public Method Check whether BOM exists for component 20010815
4 CHECK_BOM_FOR_DISPO Instance method Public Method Read the BOMs for MRP Check and Recursion Check 20011106
5 CHECK_CMPID_DATA Instance method Public Method Check component data (valid unit, quantity, ...) 20011121
6 CHECK_EXISTENCE Instance method Public Method Checks existence and gets basic data (unit of measure, type) 20010802
7 CHECK_VERSION_ACTIVE Instance method Public Method Checks whether the version in the system is active 20011001
8 CMPID_ACTIVE Instance method Public Method Check Existence of Connection to Material Master 20020116
9 CMPID_CHK Instance method Public Method Consistency Check Function for Production Version 20030811
10 CMPID_GET_BY_RANGE Instance method Public Method Read components from RANGES table 20020128
11 CMPID_LOCID_READ Instance method Public Method Checks existence and gets plant-dependent data (CUOBJ, KMAT) 20011128
12 CMPID_TEXT Instance method Public Method Gets the field names 20020125
13 CMPID_UNLOCK Instance method Public Method Unlock Components 20020403
14 CONVERT_CMPID Instance method Public Method Conversion of components internal <-> external in iPPE 20011004
15 CTMENU_ADD Instance method Public Method System-Specific Enhancement of Context Menu 20021108
16 CTMENU_SELECT Instance method Public Method System-Specific Execution of Context Menu Operations 20021108
17 EKG Instance method Public Method Data Analysis and Correction 20011105
18 GET_CMPID_FROM_CMPEXT_RANGE Instance method Public Method Determine Internal Material Number From CPEXT Range Table 20030129
19 GET_CMPID_LENGTH Instance method Public Method Read Length of Material Number 20020916
20 GET_CMPID_PHANTOM Instance method Public Method Checks Material for Phantom Indicator (SOBSL) 20030327
21 GET_DDIC_FIELD Instance method Public Method Read DDIC Field for Material Number 20041104
22 GET_DESCRIPTIONS Instance method Public Method Read texts for component / component type 20020125
23 GET_DISPO_FOR_CMPID Instance method Public Method Read the low-level codes for the components 20010808
24 GET_DYNPRO_INFORMATION Instance method Public Method Gets screen and program for component display 20011205
25 GET_SEARCH_HELP_NAME Instance method Public Method Read Search Help for Material Number 20021025
26 GET_UNITS Instance method Public Method Read units of measure for the component 20010802
27 GET_VERSION_INFO Instance method Public Method Gets information on the versions of components 20010802
28 HELP_INFO_CALL Instance method Public Method Starts the Online Component Documentation 20040813
29 PLANNING_TABLE_UPDATE Instance method Public Method Update the planning file entry 20011105
30 SET_CMPID_SPECIAL_FUNCT Instance method Public Method Set special functions for components 20011024
31 SET_DISPO_FOR_CMPID Instance method Public Method Set new low-level codes for components 20010808
32 VALUE_INFO_CALL Instance method Public Method Starts the Component Input Help 20040813
Events
Interface IF_EX_IPPE_CMPID has no event.
Types
Interface IF_EX_IPPE_CMPID has no local type.
Method Signatures

Method CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CALL 20030415
2 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal Identification of the Component (Material/Product) 20011022
3 Importing IM_MODE Call by reference Type reference (TYPE) C Mode [Display/Change] 20011022
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20011022
# Exception Resumable Description Created on
1 CALL_ERROR Error accessing the display/change transaction 20011022

Method CALL_CMPID_FROM_SCREEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CREATE_CANCEL Call by reference Type reference (TYPE) C Kennzeichen: Anlegen der Komponente abgebrochen 20031024
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CALL_CMPID_FROM_SCREEN 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal component display 20011023
4 Importing IM_CMPID_EXT Call by reference Type reference (TYPE) CMPID_EXT externe Komponentendarstellung 20020813
5 Importing IM_MODE Call by reference Type reference (TYPE) C Operation (Display/Change/Create) 20011023
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011023
7 Importing IM_SAVE_FLG Call by reference Type reference (TYPE) C Indicator: Deal with the Save-Routine 20011024
8 Importing IM_SCREEN_INIT_FLG Call by reference Type reference (TYPE) C Indicator: Update Screen 20011024
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20011023

Method CHECK_BOM_DECOMPOSITION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_BOM_DECOMPOSITION 20030415
2 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20010815
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20010815
4 Importing IM_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Variant 20011218
5 Importing IM_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT External Description of the Variant 20010815
6 Importing IM_PVDESC Call by reference Type reference (TYPE) PVS_DESC External Description of the Type 20010815
# Exception Resumable Description Created on
1 BOM_ERROR BOM exists 20010815

Method CHECK_BOM_FOR_DISPO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_CMPID_CHECK_TAB Call by reference Type reference (TYPE) PPENV_CMPID_TAB Components for Recursiveness Check 20011106
2 Exporting EX_DECOMPOSITION_TAB Call by reference Type reference (TYPE) PPENV_BOM_DEC_TAB Component Breakdown from BOM 20011106
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_BOM_FOR_DISPO 20030415
4 Importing IM_CMPID_TAB Call by reference Type reference (TYPE) PPENV_CMPID_TAB Components for BOM Check 20011106
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011106
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20011106

Method CHECK_CMPID_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_CMPID_DATA 20030415
2 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20011121
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011121
4 Importing IM_QUANT Call by reference Type reference (TYPE) PVS_QUANT Quantity for Unit 20011121
5 Importing IM_UNIT Call by reference Type reference (TYPE) PVS_QUNIT Unit of Measure 20011121
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20011121

Method CHECK_EXISTENCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_FIELDS Call by reference Type reference (TYPE) PPENV_CMPID_FIELDS Data for components from master record 20010802
2 Exporting EX_EXISTS Call by reference Type reference (TYPE) C Component exists ['X', ' '] 20010802
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_EXISTENCE 20030415
4 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20010802
5 Importing IM_DELFLG_CHECK Call by reference Type reference (TYPE) C PPET_FALSE Flag: Prüfen, ob Komponente Löschkennzeichen hat ['X', ' '] 20021015
6 Importing IM_EXTENDED_CHECK Call by reference Type reference (TYPE) C PPET_FALSE Flag: Erweiterte Prüfungen für iPPE-Produktstruktur ['X', ' 20021104
7 Importing IM_HEAD_ALLOWED Call by reference Type reference (TYPE) C PPET_TRUE Flag: Kopfkomponente von Version erlaubt ['X', ' '] 20021114
8 Importing IM_LOCK_TYPE Call by reference Type reference (TYPE) C PPET_FALSE Lock Components ['E', 'S', ' '] 20020403
9 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20010802
10 Importing IM_MSG_TYPE Call by reference Type reference (TYPE) C Message Type for Message 20010809
11 Importing IM_PVTYPE Call by reference Type reference (TYPE) PPET_PVTYPE Variantentyp (notwendig für erweiterte Prüfungen) 20021104
12 Importing IM_STATUS_CHECK Call by reference Type reference (TYPE) C PPET_FALSE Flag: Status für Komponentenverwendung prüfen ['X', ' '] 20021104
13 Importing IM_VERSION_ALLOWED Call by reference Type reference (TYPE) C PPET_FALSE Flag: Komponentenversion erlauben ['X', ' '] 20021108
# Exception Resumable Description Created on
1 EXISTENCE_ERROR Component Does Not Exist 20010802

Method CHECK_VERSION_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ACTIVE Call by reference Type reference (TYPE) C Versions active ['X', ' '] 20011001
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_VERSION_ACTIVE 20030415

Method CHECK_VERSION_ACTIVE on Interface IF_EX_IPPE_CMPID has no exception.

Method CMPID_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning EX_CMPID_ACTIVE Value transfer Type reference (TYPE) XFELD Material Master Exists ['X', ' '] 20020116
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_ACTIVE 20030415

Method CMPID_ACTIVE on Interface IF_EX_IPPE_CMPID has no exception.

Method CMPID_CHK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CMPID_STATUS Call by reference Type reference (TYPE) PPENV_CMPID_STATUS_TYPE Statusinformation zur Komponente 20030811
2 Exporting EV_CMPID_LOCID_ERROR Call by reference Type reference (TYPE) C Kennzeichen: Komponente existiert nocht in Lokation 20030812
3 Exporting EV_DP_ERROR Call by reference Type reference (TYPE) C Kennzeichen: Verwendung in Absatzplanung nicht erlaubt 20040206
4 Exporting EV_TEXT_001 Call by reference Type reference (TYPE) C Beispiel: "werksspezifischer Materialstatus" 20030811
5 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Systemumgebung, in der das iPPE genutzt wird (INS 614180) 20030811
6 Importing IV_CHECK_FLG Call by reference Type reference (TYPE) C PPET_FALSE Flag: Status-Daten prüfen 20030811
7 Importing IV_CMPID Call by reference Type reference (TYPE) PVS_CMPID Interne Identifikation der Komponente (Material/Produkt) 20030811
8 Importing IV_CUST_FLG Call by reference Type reference (TYPE) C PPET_FALSE Flag: Customizing für Komponentenstatus lesen 20030812
9 Importing IV_LOCID Call by reference Type reference (TYPE) PPE_LOCID Werk/Lokation in PPE 20030811
10 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenparameter im iPPE 20030811
11 Importing IV_STATUS_FLG Call by reference Type reference (TYPE) C PPET_FALSE Flag: Status-Daten prüfen 20040206
12 Importing IV_TEXT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Flag: Textbezeichnungen zurückgeben 20030811
# Exception Resumable Description Created on
1 GENERAL_ERROR allgemeiner Fehler 20030811

Method CMPID_GET_BY_RANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_TAB Call by reference Type reference (TYPE) PPENV_CMPID_TAB 20020128
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_GET_BY_RANGE 20030415
3 Importing IM_CMPID_SEL_TAB Call by reference Type reference (TYPE) PPENV_CMPID_SEL_TAB 20020128
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020128

Method CMPID_GET_BY_RANGE on Interface IF_EX_IPPE_CMPID has no exception.

Method CMPID_LOCID_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_C_CMPID_FIELDS Call by reference Type reference (TYPE) PPENV_C_CMPID_FIELDS C-Data for components 20011128
2 Exporting EX_DUMMY_FLG Call by reference Type reference (TYPE) C Komponente ist Dummy ['X', ' '] 20030110
3 Exporting EX_EXISTS Call by reference Type reference (TYPE) C Component exists ('X', ' ') 20011128
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_LOCID_READ 20030415
5 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20011128
6 Importing IM_DUMMY_FLG Call by reference Type reference (TYPE) C PPET_TRUE Prüfen ob Komponente Dummy ist ? 20030805
7 Importing IM_LOCID Call by reference Type reference (TYPE) PPE_LOCID Plant 20011128
8 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011128
9 Importing IM_MSG_TYPE Call by reference Type reference (TYPE) C Message Type for Message 20011128
# Exception Resumable Description Created on
1 EXISTENCE_ERROR C-Data does not exist 20011128

Method CMPID_TEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_BUS_OBJECT Call by reference Type reference (TYPE) SWO_OBJTYP Object Type 20020128
2 Exporting EX_TEXT Value transfer Type reference (TYPE) TEXT40 Field Label 20020125
3 Exporting EX_TEXT_2 Call by reference Type reference (TYPE) C 20020128
4 Exporting EX_TEXT_3 Call by reference Type reference (TYPE) C 20020128
5 Exporting EX_TEXT_4 Call by reference Type reference (TYPE) C 20030219
6 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_TEXT 20030415

Method CMPID_TEXT on Interface IF_EX_IPPE_CMPID has no exception.

Method CMPID_UNLOCK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CMPID_UNLOCK 20030415
2 Importing IM_ALL_CMPID_FLG Call by reference Type reference (TYPE) C PPET_TRUE Indicator: Unlock all materials 20020403
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal Identification of the Component (Material/Product) 20020403
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020403
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20020403

Method CONVERT_CMPID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal component display 20011004
2 Exporting EX_CMPID_EXT Call by reference Type reference (TYPE) CMPID_EXT External component display 20011004
3 Exporting EX_CMPID_EXT_NO_MASK Call by reference Type reference (TYPE) CMPID_EXT External component display without template 20011018
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CONVERT_CMPID 20030415
5 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal component display 20011004
6 Importing IM_CMPID_EXT Call by reference Type reference (TYPE) CMPID_EXT External component display 20011004
7 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011004
# Exception Resumable Description Created on
1 GENERAL_ERROR Error converting the components 20011004

Method CTMENU_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_MENU Call by reference Object reference (TYPE REF TO) CL_CTMENU Kontextmenü 20021108
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_ADD 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Objektidentifikation 20021108
4 Importing IM_MODE Call by reference Type reference (TYPE) C 20021111
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021108
# Exception Resumable Description Created on
1 MENU_ADD_ERROR Fehler beim Ergänzen des Kontextmenüs 20021108

Method CTMENU_SELECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PROCESSED Call by reference Type reference (TYPE) C 20021108
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_SELECT 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Interne Identifikation der Komponente (Material/Produkt) 20021108
4 Importing IM_MODE Call by reference Type reference (TYPE) C 20021111
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021108
6 Importing IM_OKCODE Call by reference Type reference (TYPE) SY-UCOMM Bildschirmbilder, Funktionscode, der PAI ausgelöst hat 20021108
# Exception Resumable Description Created on
1 CTMENU_SELECT_ERROR Fehler beim Ausführen der Operation aus dem Kontextmenü 20021108

Method EKG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode EKG 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20011105
3 Importing IM_REPAIR Call by reference Type reference (TYPE) C PPET_FALSE Activate correction mode 20011105
# Exception Resumable Description Created on
1 CMPID_EKG_ERROR Error when analyzing and correcting the data 20011105

Method GET_CMPID_FROM_CMPEXT_RANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_TAB Call by reference Type reference (TYPE) PPENV_CMPID_TAB Liste der internen Materialnummern 20030129
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_CMPID_FROM_CMPEXT_RANGE 20030415
3 Importing IM_CMPID_EXT_R_TAB Call by reference Type reference (TYPE) PPENV_CMPID_EXT_SEL_TAB Ranges-Tabelle mit externen Materialnummern 20030129
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030129
# Exception Resumable Description Created on
1 GET_FROM_CMPEXT_RANGE_ERROR Fehler beim Lesen der internen Materialnummern 20030129

Method GET_CMPID_LENGTH Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_LENGTH_CMPID Call by reference Type reference (TYPE) I Länge CMPID 20020916
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_CMPID_LENGTH 20030415
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message-Handling der iPPE-Engine 20020917
# Exception Resumable Description Created on
1 GET_LENGTH_ERROR Fehler bei der ermittlung der Feldlänge 20020917

Method GET_CMPID_PHANTOM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_LOCID_TAB Call by reference Type reference (TYPE) PPENV_CMPLOC_INT_TAB Komponenten ohne Dummy-Kennzeichen 20030327
2 Exporting EX_PHANTOM_TAB Call by reference Type reference (TYPE) PPENV_CMPLOC_INT_TAB Komponenten mit Dummy-Kennzeichen 20030327
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_CMPID_PHANTOM 20030415
4 Importing IM_CMPID_LOCID_TAB Call by reference Type reference (TYPE) PPENV_CMPLOC_INT_TAB Komponenten (CMPID/LOCID) 20030327
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030327
# Exception Resumable Description Created on
1 PHANTOM_GET_ERROR Fehler beim Lesen der Dummy-Materialien 20030327

Method GET_DDIC_FIELD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning EX_DDIC_FIELD Value transfer Type reference (TYPE) CHAR40 DDIC Feld 20041104
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_DDIC_FIELD 20041104
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20041104
# Exception Resumable Description Created on
1 ERROR_GET_DDIC_FIELD Lesefehler bei der Ermittlung des DDIC Feldes 20041104

Method GET_DESCRIPTIONS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_EXT Call by reference Type reference (TYPE) CMPID_EXT External Material Number 20020125
2 Exporting EX_CMPID_TEXT Call by reference Type reference (TYPE) CHAR40 Character Field of Length 40 20020125
3 Exporting EX_TYPE_TEXT Call by reference Type reference (TYPE) PPE_MTBEZ Material Type 20020125
4 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_DESCRIPTIONS 20030415
5 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20020125
6 Importing IM_CMPID_TEXT Call by reference Type reference (TYPE) C PPET_TRUE Beschreibung zu Material lesen ? 20030805
7 Importing IM_TYPE Call by reference Type reference (TYPE) CHAR4 Type of Component (E.g. FERT) 20020125

Method GET_DESCRIPTIONS on Interface IF_EX_IPPE_CMPID has no exception.

Method GET_DISPO_FOR_CMPID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_DISPO_TAB Call by reference Type reference (TYPE) PPENV_DISPO_TAB Low-level codes for components 20010808
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_DISPO_FOR_CMPID 20030415
3 Importing IM_CMPID_TAB Call by reference Type reference (TYPE) PPENV_CMPID_TAB Components 20010808

Method GET_DISPO_FOR_CMPID on Interface IF_EX_IPPE_CMPID has no exception.

Method GET_DYNPRO_INFORMATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PROGRAM Call by reference Type reference (TYPE) SY-REPID ABAP-Program, Function Group 20011205
2 Exporting EX_SCREEN Call by reference Type reference (TYPE) SY-DYNNR ABAP Program: Number of Current Screen 20011205
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_DYNPRO_INFORMATION 20030415

Method GET_DYNPRO_INFORMATION on Interface IF_EX_IPPE_CMPID has no exception.

Method GET_SEARCH_HELP_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_SEARCH_HELP_NAME Call by reference Type reference (TYPE) SHLPNAME Name einer Suchhilfe 20021025
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_SEARCH_HELP_NAME 20030415
3 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL 20021025
# Exception Resumable Description Created on
1 ERROR_READ_SEARCH_HELP Lesefehler bei der Ermittlung der Suchhilfe 20021025

Method GET_UNITS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_UNIT_TAB Call by reference Type reference (TYPE) PPENV_UNIT_TAB Valid Units of Measure 20010802
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_UNITS 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20010802
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011105
5 Importing IM_UNIT Call by reference Type reference (TYPE) PVS_QUNIT Base Unit of Measure for Component 20010802
# Exception Resumable Description Created on
1 UNIT_GET_ERROR Error reading the alternative units of measure 20010802

Method GET_VERSION_INFO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CMPID_TAB Call by reference Type reference (TYPE) PPENV_CMPID_VERSION_TAB Information on versions for the component 20010808
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_VERSION_INFO 20030415
3 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Component 20010802
4 Importing IM_COLOR_FLG Call by reference Type reference (TYPE) C PPET_FALSE Flag: Farbversion 20021114
5 Importing IM_HEAD_FLG Call by reference Type reference (TYPE) C PPET_TRUE Flag: Komponente ist Kopf 20021114
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichtenhandling im iPPE 20021114

Method GET_VERSION_INFO on Interface IF_EX_IPPE_CMPID has no exception.

Method HELP_INFO_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_VERSION_INFO 20040813
2 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenhandling im iPPE 20040813
3 Importing IV_UI_ID Call by reference Type reference (TYPE) PPENV_UI_ID Steuerungskennzeichen des aufrufenden UI 20040813
# Exception Resumable Description Created on
1 GENERAL_ERROR Fehler bei Ausführung der Online-Dokumentation 20040813

Method PLANNING_TABLE_UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PLANNING_TABLE_UPDATE 20030415
2 Importing IM_CMPID Call by reference Type reference (TYPE) PVS_CMPID Internal Identification of the Component (Material/Product) 20011105
3 Importing IM_DISST Call by reference Type reference (TYPE) CHAR3 3-Byte field 20011105
4 Importing IM_LOCID Call by reference Type reference (TYPE) PPE_LOCID Plant/Location in iPPE 20011105
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011105
# Exception Resumable Description Created on
1 GENERAL_ERROR General error in the planning file entry 20011105

Method SET_CMPID_SPECIAL_FUNCT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode SET_CMPID_SPECIAL_FUNCT 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011024
# Exception Resumable Description Created on
1 GENERAL_ERROR General error 20011024

Method SET_DISPO_FOR_CMPID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode SET_DISPO_FOR_CMPID 20030415
2 Importing IM_DISPO_SET_TAB Call by reference Type reference (TYPE) PPENV_DISPO_SET_TAB Low-level codes for components 20010808

Method SET_DISPO_FOR_CMPID on Interface IF_EX_IPPE_CMPID has no exception.

Method VALUE_INFO_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_CMPEXT Call by reference Type reference (TYPE) CMPID_EXT externe ID der selektierten Komponente 20040813
2 Exporting ET_CMPEXT Call by reference Type reference (TYPE) PPENV_CMPID_EXT_TAB externe IDs der selektierten Komponenten 20050208
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode GET_CMPID_PHANTOM 20040813
4 Importing IS_CMPEXT Call by reference Type reference (TYPE) CMPID_EXT Vorbelegung für Suchhilfe 20040813
5 Importing IV_DISPLAY_FLG Call by reference Type reference (TYPE) C PPET_FALSE Kennzeichen: Aufruf in Anzeigemodus 20040910
6 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenhandling im iPPE 20040813
7 Importing IV_MULT_FLG Call by reference Type reference (TYPE) C PPET_FALSE Kennzeichen: mehrfache Auswahl zulassen ['X', ' '] 20050208
8 Importing IV_UI_ID Call by reference Type reference (TYPE) PPENV_UI_ID Steuerungskennzeichen des aufrufenden UIs 20040813
# Exception Resumable Description Created on
1 GENERAL_ERROR allgemeiner Fehler bei der Eingabehilfe zur Komponente 20040813
History
Last changed by/on SAP  20050220 
SAP Release Created in 110