SAP ABAP Interface IF_EX_IPPE_CLASS (BAdI Interface IF_EX_IPPE_CLASS)
Hierarchy
EA-IPPE (Software Component) SAP iPPE
   AP-PPE (Application Component) Integrated Product and Process Engineering
     CPPEENV (Package) Decoupling of iPPE Environment
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_IPPE_CLASS BAdI Class CL_EX_IPPE_CLASS 20010808
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_PPER3E_CLASS BAdI Implementation for IPPE_CLASS 20010820
Properties
Interface IF_EX_IPPE_CLASS  
Short Description BAdI Interface IF_EX_IPPE_CLASS    
General Data
Package CPPEENV   Decoupling of iPPE Environment 
Created 20010808   SAP 
Last changed 20041209   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 PPENV Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 PPET Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_IPPE_CLASS has no interface.
Friends
Interface IF_EX_IPPE_CLASS has no friend.
Attributes
Interface IF_EX_IPPE_CLASS has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHARACTERISTIC_CALL Instance method Public Method Call Characteristics Maintenance 20011019
2 CHARACTERISTIC_GET Instance method Public Method Read Characteristic 20010810
3 CHECK_CLASS_FOR_PXXXID Instance method Public Method Checks for which object classification can be used 20021112
4 CLASSIFICATION_CHECK Instance method Public Method Check if Classification Allowed for Node/Variant 20030829
5 CLASSIFICATION_COPY Instance method Public Method Copy the Classification in the Copy of the iPPE Object 20011022
6 CLASSIFICATION_DELETE Instance method Public Method Deletion of Classification 20020207
7 CLASSIFICATION_MAINTAIN Instance method Public Method Maintain Classification 20030901
8 CLASSIFICATION_OBTAB_GET Instance method Public Method Entry in Table OBTAB for Nodes/Variants 20040930
9 CLASSIFICATION_READ Instance method Public Method Read Classification 20030829
10 CLASSIFICATION_SAVE Instance method Public Method Save Classification 20030901
11 CLASSTYPE_GET Instance method Public Method Read Class Type 20011115
12 CLASS_ACTIVE Instance method Public Method Classification system exists in system 20020118
13 CLASS_CALL Instance method Public Method Call Class Maintenance 20011019
14 CLASS_GET Instance method Public Method Read Classes 20010810
15 CLASS_GET_BY_RANGE Instance method Public Method Read the Classes from RANGES Table 20020403
16 CTMENU_ADD Instance method Public Method System-Specific Enhancement of Context Menu 20021108
17 CTMENU_SELECT Instance method Public Method System-Specific Execution of Context Menu Operations 20021108
18 EKG Instance method Public Method Data Analysis and Correction 20011105
19 HIERARCHY_CALL Instance method Public Method Call Maintenance of the Class Hierarchy 20011019
20 HIERARCHY_CHECK Instance method Public Method Check the classes for arrangement of hierarchy 20010817
21 HIERARCHY_GET Instance method Public Method Read hierarchy 20010810
22 OBJECT_ALLOCATION_READ Instance method Public Method Classification: Read Assignments to Object 20030912
23 PNODID_CHECK Instance method Public Method Check whether class is valid for nodes 20010817
24 POSVID_CHECK Instance method Public Method Check whether class is valid for variants 20010817
Events
Interface IF_EX_IPPE_CLASS has no event.
Types
Interface IF_EX_IPPE_CLASS has no local type.
Method Signatures

Method CHARACTERISTIC_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHARACTERISTIC_CALL 20030415
2 Importing IM_CHARACT_NAME Call by reference Type reference (TYPE) PPENV_CHARACT-NAME Name of Characteristic 20020103
3 Importing IM_MODE Call by reference Type reference (TYPE) C PPET_OP_ID-READ Mode (Display/Change) 20020103
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in iPPE Engine 20020103
# Exception Resumable Description Created on
1 CHARACTERISTIC_CALL_ERROR Error when calling the transaction for characteristics 20020103

Method CHARACTERISTIC_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CHARACT_TAB Call by reference Type reference (TYPE) PPENV_CHARACT_TAB Table of Characterstics Data 20020103
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHARACTERISTIC_GET 20030415
3 Importing IM_CHAR_NAME Call by reference Type reference (TYPE) PPENV_CHARACT-NAME Read Individual Characteristic By Name 20020103
4 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS Read Characteristics for Class 20020103
5 Importing IM_DATE Call by reference Type reference (TYPE) DATUM Gültigkeitsdatum 20040329
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20010810
# Exception Resumable Description Created on
1 CHARACT_GET_ERROR Error reading the characteristics 20010810

Method CHECK_CLASS_FOR_PXXXID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_OTYPE Call by reference Type reference (TYPE) PVS_OTYPE Objekttyp (Knoten oder Variante) 20021112
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CHECK_CLASS_FOR_PXXXID 20030415
3 Importing IM_CLINT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT interne Klassennummer 20021112
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021112
# Exception Resumable Description Created on
1 ERROR Fehler bei der Prüfung 20021112

Method CLASSIFICATION_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_CHECK 20030829
2 Importing IS_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Knoten 20030829
3 Importing IS_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Variante 20030829
4 Importing IV_KLART Call by reference Type reference (TYPE) PPET_CLASS-KLART Klassenart 20030829
5 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030829
6 Importing IV_OTYPE Call by reference Type reference (TYPE) PVS_OTYPE Objekttyp des iPPE 20030829
7 Importing IV_PNTYPE Call by reference Type reference (TYPE) PPET_PNTYPE Customizing Knotentyp 20030829
8 Importing IV_PVTYPE Call by reference Type reference (TYPE) PPET_PVTYPE Customizing Variantentyp 20030829
# Exception Resumable Description Created on
1 TYPE_CHECK_ERROR Klassifizierung für Knoten/Variante unzulässig 20030829

Method CLASSIFICATION_COPY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_COPY 20030415
2 Importing IM_AENNR_COPY Call by reference Type reference (TYPE) PVS_AENNR Change status of the copy 20011022
3 Importing IM_AENNR_MASTER Call by reference Type reference (TYPE) PVS_AENNR Change status of the template for the copy 20011022
4 Importing IM_GUID_COPY Call by reference Type reference (TYPE) PVS_GUID Object identification of the copy 20011022
5 Importing IM_GUID_MASTER Call by reference Type reference (TYPE) PVS_GUID Object identification of the template for the copy 20011022
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20011022
7 Importing IM_OTYPE Call by reference Type reference (TYPE) PVS_OTYPE iPPE Object Type 20011022
8 Importing IM_SAVE_FLG Call by reference Type reference (TYPE) XFELD PPET_FALSE Indicator: Run Save Routine 20020207
# Exception Resumable Description Created on
1 GENERAL_ERROR Error copying the object classification 20011022

Method CLASSIFICATION_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_DELETE 20030415
2 Importing IM_AENNR Call by reference Type reference (TYPE) PVS_AENNR Definition of the Change Number in iPPE 20020207
3 Importing IM_GUID Call by reference Type reference (TYPE) PPET_APPL_GUID Object identification in iPPE 20020207
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020207
# Exception Resumable Description Created on
1 GENERAL_ERROR Error when deleting the configuration 20020207

Method CLASSIFICATION_MAINTAIN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_CHARVAL Call by reference Type reference (TYPE) PPENV_CHARVAL_MAINT_TAB Werte Klassifizierung 20030909
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_READ 20030901
3 Importing IS_GUID Call by reference Type reference (TYPE) PPET_APPL_GUID Objektidentifikation im iPPE 20030901
4 Importing IT_CHARVAL Call by reference Type reference (TYPE) PPENV_CHARVAL_MAINT_TAB Werte Klassifizierung 20030901
5 Importing IV_AENNR Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer 20030901
6 Importing IV_CLASS Call by reference Type reference (TYPE) PPE_CLASS Klassennummer 20030901
7 Importing IV_CLASSTYPE Call by reference Type reference (TYPE) PPE_KLASSENART Klassenart 20030901
8 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030901
9 Importing IV_NO_DEFAULTS Call by reference Type reference (TYPE) PPE_XFELD Keine Defaultbewertung bei neuer Zuordnung 20030901
10 Importing IV_OBJ_NOT_CHK Call by reference Type reference (TYPE) PPE_XFELD OBJECT_CHECK_XXXX nicht ausführen 20030901
# Exception Resumable Description Created on
1 MAINTAIN_ERROR Fehler beim Anlegen der Klassifizierung 20030901

Method CLASSIFICATION_OBTAB_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_OBTAB_FOR_NODE Call by reference Type reference (TYPE) PPENV_OBTAB_TAB Objekttabellen 20040930
2 Exporting ET_OBTAB_FOR_VARIANT Call by reference Type reference (TYPE) PPENV_OBTAB_TAB Objekttabellen 20040930
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_OBTAB_GET 20040930
4 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT Nachrichtenhandhabung im iPPE 20040930
# Exception Resumable Description Created on
1 ERROR Fehler 20040930

Method CLASSIFICATION_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_CHARVAL Call by reference Type reference (TYPE) PPENV_CHARVAL_TAB Werte Klassifizierung 20030901
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_READ 20030829
3 Importing IS_GUID Call by reference Type reference (TYPE) PPET_APPL_GUID Objektidentifikation im iPPE 20030901
4 Importing IV_AENNR Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer 20030901
5 Importing IV_CLASS Call by reference Type reference (TYPE) PPE_CLASS Klassennummer 20030901
6 Importing IV_CLASSTYPE Call by reference Type reference (TYPE) PPE_KLASSENART Klassenart 20030901
7 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030901
8 Importing IV_WITH_INHERITED_CHARACTS Call by reference Type reference (TYPE) PPE_XFELD PPET_TRUE mit vererbten Merkmalen 20030912
9 Importing IV_WITH_UNASSIGNED_CHARACTS Call by reference Type reference (TYPE) PPE_XFELD PPET_FALSE mit unbewerteten Merkmalen 20030912
# Exception Resumable Description Created on
1 READ_ERROR Fehler beim Lesen der Klassifizierung 20030829

Method CLASSIFICATION_SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_SAVE 20030901
2 Importing IV_COMMIT Call by reference Type reference (TYPE) PPE_XFELD PPET_TRUE Commit wird durchgeführt 20030901
3 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030901
4 Importing IV_NO_CHECK Call by reference Type reference (TYPE) PPE_XFELD PPET_FALSE X: kein Check auf und Rekursivität und Status 20030901
5 Importing IV_NO_UPD_TASK Call by reference Type reference (TYPE) PPE_XFELD PPET_TRUE Verbuchung passiert nicht im UPDATE_TASK 20030901
6 Importing IV_WAIT Call by reference Type reference (TYPE) PPE_XFELD PPET_FALSE Warten, bis Commit durchgeführt ist 20030901
# Exception Resumable Description Created on
1 SAVE_ERROR Fehler beim Speichern 20030901

Method CLASSTYPE_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLASSTYPE_DESC Call by reference Type reference (TYPE) CHAR40 Description 20011115
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSTYPE_GET 20030415
3 Importing IM_CLASSTYPE Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20011115
4 Importing IM_LANGU Call by reference Type reference (TYPE) SY-LANGU SY-LANGU Language 20011115
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20020205
# Exception Resumable Description Created on
1 CLASSTYPE_ERROR Error reading the class type 20011115

Method CLASS_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning EX_CLASS_ACTIVE Value transfer Type reference (TYPE) XFELD Classification System is Active 20020118
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASS_ACTIVE 20030415

Method CLASS_ACTIVE on Interface IF_EX_IPPE_CLASS has no exception.

Method CLASS_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASS_CALL 20030415
2 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Ext. Class Number 20020103
3 Importing IM_CLASS_INT Call by reference Type reference (TYPE) PPE_CLINT Internal class number 20020102
4 Importing IM_CLASS_TYPE Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20020103
5 Importing IM_MODE Call by reference Type reference (TYPE) C PPET_OP_ID-READ Mode 20011019
6 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in iPPE Engine 20011019
# Exception Resumable Description Created on
1 CALL_ERROR Error accessing the class maintenance 20011019

Method CLASS_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLASS_EXT Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Class 20010820
2 Exporting EX_CLASS_EXT_TEXT Call by reference Type reference (TYPE) CHAR40 Description of external class entry 20011025
3 Exporting EX_CLASS_INT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Class Key 20010820
4 Exporting EX_CLASS_INT_TEXT Call by reference Type reference (TYPE) CHAR40 Description of internal class entry 20011025
5 Exporting EX_CLASS_TYPE Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20010820
6 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASS_GET 20030415
7 Importing IM_CLASS_EXT Call by reference Type reference (TYPE) PPENV_CLASS-CLASS Class 20010820
8 Importing IM_CLASS_INT Call by reference Type reference (TYPE) PPENV_CLASS-CLINT Internal Class Key 20010820
9 Importing IM_CLASS_TYPE Call by reference Type reference (TYPE) PPENV_CLASS-TYPE Class Type 20010820
10 Importing IM_LANGU Call by reference Type reference (TYPE) SY-LANGU SY-LANGU Language for Description 20011026
11 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20010810
12 Importing IM_WITH_TEXT Call by reference Type reference (TYPE) C PPET_TRUE Beschreibungen zu Klassen lesen ? 20030805
# Exception Resumable Description Created on
1 CLASS_GET_ERROR Error Reading the Class 20010810

Method CLASS_GET_BY_RANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLASS_TAB Call by reference Type reference (TYPE) PPENV_CLASS_TAB 20020403
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASS_GET_BY_RANGE 20030415
3 Importing IM_CLASS_SEL_TAB Call by reference Type reference (TYPE) PPENV_CLASS_SEL_TAB 20020403
4 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20020403

Method CLASS_GET_BY_RANGE on Interface IF_EX_IPPE_CLASS has no exception.

Method CTMENU_ADD Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CH_MENU Call by reference Object reference (TYPE REF TO) CL_CTMENU Kontextmenü 20021108
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_ADD 20030415
3 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS Objektidentifikation 20021108
4 Importing IM_MODE Call by reference Type reference (TYPE) C 20021111
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021108
# Exception Resumable Description Created on
1 MENU_ADD_ERROR Fehler beim Ergänzen des Kontextmenüs 20021108

Method CTMENU_SELECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_PROCESSED Call by reference Type reference (TYPE) C 20021108
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CTMENU_SELECT 20030415
3 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS 20021108
4 Importing IM_MODE Call by reference Type reference (TYPE) C 20021111
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL steuert das Message Handling der iPPE Engine 20021108
6 Importing IM_OKCODE Call by reference Type reference (TYPE) SY-UCOMM Bildschirmbilder, Funktionscode, der PAI ausgelöst hat 20021108
# Exception Resumable Description Created on
1 CTMENU_SELECT_ERROR Fehler beim Ausführen der Operation aus dem Kontextmenü 20021108

Method EKG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode EKG 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20011105
3 Importing IM_REPAIR Call by reference Type reference (TYPE) C PPET_FALSE Activate correction mode 20011105
# Exception Resumable Description Created on
1 CLASS_EKG_ERROR Error when analyzing and correcting the data 20011105

Method HIERARCHY_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode HIERARCHY_CALL 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in iPPE Engine 20011019
# Exception Resumable Description Created on
1 CALL_ERROR Error accessing the class maintenance 20011019

Method HIERARCHY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode HIERARCHY_CHECK 20030415
2 Importing IM_CLASS1_INT Call by reference Type reference (TYPE) PPE_CLINT Internal class number 20010817
3 Importing IM_CLASS2_INT Call by reference Type reference (TYPE) PPE_CLINT Internal class number 20010817
4 Importing IM_MSGNO Call by reference Type reference (TYPE) BALMI-MSGNO Messages, Message Number 20010817
5 Importing IM_MSGV1 Call by reference Type reference (TYPE) BALMI-MSGV1 Messages, Message Variables 20010817
6 Importing IM_MSGV2 Call by reference Type reference (TYPE) BALMI-MSGV2 Messages, Message Variables 20010817
7 Importing IM_MSGV3 Call by reference Type reference (TYPE) BALMI-MSGV3 Messages, Message Variables 20010817
8 Importing IM_MSGV4 Call by reference Type reference (TYPE) BALMI-MSGV4 Messages, Message Variables 20010817
9 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20010817
# Exception Resumable Description Created on
1 HIERARCHY_ERROR Error when checking the hierarchy 20010817

Method HIERARCHY_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_CLASSTREE_TAB Call by reference Type reference (TYPE) PPENV_CLINT_LEVEL_TAB Classes (internal) as tree 20010820
2 Exporting EX_CLASS_TAB Call by reference Type reference (TYPE) PPENV_CLASS_TAB Classes (internal) of hierarchy 20010820
3 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode HIERARCHY_GET 20030415
4 Importing IM_CLASS Call by reference Type reference (TYPE) PPENV_CLASS Class identification of the start class 20010820
5 Importing IM_DOWN_FLG Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Read Hierarchy Downwards 20010820
6 Importing IM_HIERARCHY_FLG Call by reference Type reference (TYPE) C PPET_TRUE Indicator: Output Classes in the Hierarchy 20010820
7 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Controls Message Handling in the iPPE Engine 20010810
8 Importing IM_TREE_FLG Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Output Classes in the Hierarchy as a Tree 20010820
9 Importing IM_UP_FLG Call by reference Type reference (TYPE) C PPET_FALSE Indicator: Read Hierarchy Upwards 20010820
# Exception Resumable Description Created on
1 HIERARCHY_GET_ERROR Error Reading the Class Hierarchy 20010810

Method OBJECT_ALLOCATION_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_ALLOCATIONS Call by reference Type reference (TYPE) PPENV_OBJECT_ALLOC_TAB Alle Zuordnungen zum Objekt 20030912
2 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode CLASSIFICATION_READ 20030912
3 Importing IS_GUID Call by reference Type reference (TYPE) PPET_APPL_GUID Objektidentifikation im iPPE 20030912
4 Importing IV_AENNR Call by reference Type reference (TYPE) PVS_AENNR Änderungsnummer 20030912
5 Importing IV_CLASSTYPE Call by reference Type reference (TYPE) PPE_KLASSENART Klassenart 20030912
6 Importing IV_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Nachrichten-Handling im iPPE 20030912
7 Importing IV_OBJ_NOT_CHK Call by reference Type reference (TYPE) PPE_XFELD PPET_FALSE OBJECT_CHECK_XXXX nicht ausführen 20030912
# Exception Resumable Description Created on
1 READ_ERROR Fehler beim Lesen der Klassifizierung 20030912

Method PNODID_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode PNODID_CHECK 20030415
2 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20010817
3 Importing IM_MSG_TYPE Call by reference Type reference (TYPE) C Message Type 20010817
4 Importing IM_PNDESC Call by reference Type reference (TYPE) PVS_DESC External Description of the Type 20010817
5 Importing IM_PNODID Call by reference Type reference (TYPE) PPET_PNODID_LI Nodes 20010817
6 Importing IM_PNODID_EXT Call by reference Type reference (TYPE) PPET_PNODID_EXT External Description of Node 20010817
7 Importing IM_PNTYPE Call by reference Type reference (TYPE) PPET_PNTYPE Customizing 20010817
# Exception Resumable Description Created on
1 CLASS_CHECK_ERROR Error checking classes 20010817

Method POSVID_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) PPE_ENVIRONMENT Parameter FLT_VAL der Methode POSVID_CHECK 20030415
2 Importing IM_ASSIGNMENT Call by reference Type reference (TYPE) C Class where-used list for the variant ['1', '2', '3'] 20010817
3 Importing IM_CLASS_INT Call by reference Type reference (TYPE) PPE_CLINT Internal Class Number of Node 20010817
4 Importing IM_CLASS_INT_TAB Call by reference Type reference (TYPE) PPENV_CLINT_TAB Table of internal classes for the variant 20010817
5 Importing IM_MSG_OPT Call by reference Type reference (TYPE) PPET_MSG_OPT PPET_MSG_OPTIONS-DO_ALL Message Handling in iPPE 20010817
6 Importing IM_POSVID Call by reference Type reference (TYPE) PPET_POSVID_LI Variant 20010817
7 Importing IM_POSVID_EXT Call by reference Type reference (TYPE) PPET_POSVID_EXT External Description of the Variant 20010817
8 Importing IM_PVDESC Call by reference Type reference (TYPE) PVS_DESC External Description of the Type 20010817
# Exception Resumable Description Created on
1 CHECK_ERROR Error in the class where-used list for the variant 20010817
History
Last changed by/on SAP  20041209 
SAP Release Created in 110