SAP ABAP Interface IF_EX_HROM_NF_BUFFER (BADI Interface IF_EX_HROM_NF_BUFFER)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-BMT-OM (Application Component) Organizational Management
     SP0E (Package) HR-OM: Organizational Management Enhancements
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_HROM_NF_BUFFER BADI Class CL_EX_HROM_NF_BUFFER 20000111
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_HRCMP_NF_DATABUFFER Imp. Class of BAdI-Imp. HRCMP_NF_DATABUFFER 19991228
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_HRPIQ00_ST_NF_BUFFER Imp. Class for BAdI-Imp. HRPIQ00_ST_NF_BUFFER 20000719
Properties
Interface IF_EX_HROM_NF_BUFFER  
Short Description BADI Interface IF_EX_HROM_NF_BUFFER    
General Data
Package SP0E   HR-OM: Organizational Management Enhancements 
Created 19991227   SAP 
Last changed 00000000   SAP 
Unicode checks active    
Forward declarations
Interface IF_EX_HROM_NF_BUFFER has no forward declaration.
Interfaces
Interface IF_EX_HROM_NF_BUFFER has no interface.
Friends
Interface IF_EX_HROM_NF_BUFFER has no friend.
Attributes
Interface IF_EX_HROM_NF_BUFFER has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 ADD_NAVIGATION_STEP Instance method Public Method Note Navigation for Undo 19991227
2 ADD_UNDO_STEP Instance method Public Method Note Undo Step 19991227
3 GET_BUFFER_CHANGE_STATE Instance method Public Method Sets Flag if Buffer has Changed Since Last Access 19991227
4 GET_CHANGED_FLAG Instance method Public Method Read Change Flag 19991227
5 GET_UNDO_REDO_STATUS Instance method Public Method Is Undo/Redo Active? 19991227
6 INITIALIZE Instance method Public Method Initialize Buffer 19991227
7 REDO Instance method Public Method One Step Forwards (Redo) 19991227
8 UNDO Instance method Public Method One Step Back (Undo) 19991227
9 WRITE_BUFFER_TO_DB Instance method Public Method Write Buffer to Database 19991227
Events
Interface IF_EX_HROM_NF_BUFFER has no event.
Types
Interface IF_EX_HROM_NF_BUFFER has no local type.
Method Signatures

Method ADD_NAVIGATION_STEP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode ADD_NAVIGATION_STEP 19991227
# Exception Resumable Description Created on
1 NO_STEP_ADDED Verarbeitungsschritt konnte nicht hinzugefügt werden 19991227

Method ADD_UNDO_STEP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode ADD_UNDO_STEP 19991227
# Exception Resumable Description Created on
1 NO_STEP_ADDED Verarbeitungsschritt konnte nicht angefügt werden 19991227

Method GET_BUFFER_CHANGE_STATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting BUFFER_CHANGED Value transfer Type reference (TYPE) FLAG Flag: Puffer geändert 19991227
2 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode GET_BUFFER_CHANGE_STATE 19991227

Method GET_BUFFER_CHANGE_STATE on Interface IF_EX_HROM_NF_BUFFER has no exception.

Method GET_CHANGED_FLAG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting CHANGED_FLAG Value transfer Type reference (TYPE) FLAG Flag: Änderungen vorhanden 19991227
2 Exporting EXT_CHANGED_FLAG Value transfer Type reference (TYPE) FLAG allgemeines flag 19991227
3 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode GET_CHANGED_FLAG 19991227

Method GET_CHANGED_FLAG on Interface IF_EX_HROM_NF_BUFFER has no exception.

Method GET_UNDO_REDO_STATUS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CHANGEMODE Value transfer Type reference (TYPE) OMACTMODE 'M' Orgmanagement: Aktueller Modus 19991227
2 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode GET_UNDO_REDO_STATUS 19991227
3 Exporting REDO_ACTIVE Call by reference Type reference (TYPE) FLAG Flag: Redo Aktiv 19991227
4 Exporting REDO_NAV Call by reference Type reference (TYPE) FLAG allgemeines flag 19991227
5 Exporting UNDO_ACTIVE Call by reference Type reference (TYPE) FLAG Flag: Undo aktiv 19991227
6 Exporting UNDO_NAV Call by reference Type reference (TYPE) FLAG allgemeines flag 19991227

Method GET_UNDO_REDO_STATUS on Interface IF_EX_HROM_NF_BUFFER has no exception.

Method INITIALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode INITIALIZE 19991227
2 Importing KEEP_NAVIGATION Value transfer Type reference (TYPE) FLAG Flag: Navigation erhalten 19991227
3 Importing UNSAVED_STEPS Value transfer Type reference (TYPE) OMUNSAVEDS OM: Maximale Schritte ohne Sicherungsabfrage 19991227

Method INITIALIZE on Interface IF_EX_HROM_NF_BUFFER has no exception.

Method REDO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode REDO 19991227
# Exception Resumable Description Created on
1 REDO_ERROR Redo nicht möglich 19991227

Method UNDO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode UNDO 19991227
# Exception Resumable Description Created on
1 UNDO_ERROR Undo nicht möglich 19991227

Method WRITE_BUFFER_TO_DB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing FLT_VAL Value transfer Type reference (TYPE) HROMSCEN Parameter FLT_VAL der Methode WRITE_BUFFER_TO_DB 19991227
# Exception Resumable Description Created on
1 CORR_EXIT Abbruch auf Korrekturpopup 19991227
2 DATABASE_ERROR Fehler beim Verbuchen 19991227
History
Last changed by/on SAP  00000000 
SAP Release Created in 46C