SAP ABAP Interface IF_EX_EHSI_MP_DV_SCR (BAdI Interface IF_EX_EHSI_MP_DV_SCR)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   EHS-IHS (Application Component) Industrial Hygiene and Safety
     CBIH (Package) EH&S: Industrial Hygiene and Safety
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_DEF_IM_EHSI_MP_DV_SCR Default Implementation for BAdI Definition EHSI_MP_DV_SCR 20050407
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_EHSI_MP_DV_SCR BAdI Class CL_EX_EHSI_MP_DV_SCR 20050609
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_EHSI_MP_DV_SCR Implementation Class for BAdI Impl. EHSI_MP_DV_SCR 20050426
Properties
Interface IF_EX_EHSI_MP_DV_SCR  
Short Description BAdI Interface IF_EX_EHSI_MP_DV_SCR    
General Data
Package CBIH   EH&S: Industrial Hygiene and Safety 
Created 20050405   SAP 
Last changed 20060208   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ESP1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
# Interface Abstract Final Description Created on
1 IF_BADI_INTERFACE Tag Interface for BAdIs 20050609
Friends
Interface IF_EX_EHSI_MP_DV_SCR has no friend.
Attributes
Interface IF_EX_EHSI_MP_DV_SCR has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CALL_DEVICE_DETAIL Instance method Public Method Display Device Details 20050405
2 GET_DATA_PAI Instance method Public Method Read Screen Data at Event PAI 20050405
3 GET_DATA_PBO Instance method Public Method Read Screen Data at Event PBO 20050405
4 OKCODE_HANDLER Instance method Public Method OK-Code Handler 20050405
5 PRINT_DEVICE_LIST Instance method Public Method Print Device List 20050405
6 PUT_DATA_PAI Instance method Public Method Transfer Screen Data at Event PAI 20050405
7 PUT_DATA_PBO Instance method Public Method Transfer Screen Data at Event PBO 20050405
8 SAVE Instance method Public Method Save Device List 20050405
9 VALUE_REQUEST_DEVICE Instance method Public Method Input Help for Devices 20050405
Events
Interface IF_EX_EHSI_MP_DV_SCR has no event.
Types
Interface IF_EX_EHSI_MP_DV_SCR has no local type.
Method Signatures

Method CALL_DEVICE_DETAIL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADDINF Value transfer Type reference (TYPE) RCGADDINF EHS: Zusatzinfos für FB-Aufrufe 20050405
2 Importing I_MPDV_IOREC Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405
3 Importing I_MP_IOREC Value transfer Type reference (TYPE) CCIHS_MPIOT EHS: IOTAB für Messprojekte (CCIHT_MP) 20050405
4 Importing I_RCGDIALCTR Value transfer Type reference (TYPE) RCGDIALCTR PP-SHE: Dialogkontrollstruktur 20050405

Method CALL_DEVICE_DETAIL on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method GET_DATA_PAI Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_CHANGE Value transfer Type reference (TYPE) ESP1_BOOLEAN Kennzeichen Daten geändert 20050405
2 Exporting E_MPDV_IOTAB Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405

Method GET_DATA_PAI on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method GET_DATA_PBO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_ADDINF Value transfer Type reference (TYPE) RCGADDINF EHS: Zusatzinfos für FB-Aufrufe 20050405
2 Exporting E_MPDV_IOTAB Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405
3 Exporting E_MP_IOREC Value transfer Type reference (TYPE) CCIHS_MPIOT EHS: IOTAB für Messprojekte (CCIHT_MP) 20050405
4 Exporting E_RCGDIALCTR Value transfer Type reference (TYPE) RCGDIALCTR PP-SHE: Dialogkontrollstruktur 20050405

Method GET_DATA_PBO on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method OKCODE_HANDLER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_OKCODE Value transfer Type reference (TYPE) ESP1_OKCODE_TYPE Okcode 20050405
2 Importing I_OKCODE Value transfer Type reference (TYPE) ESP1_OKCODE_TYPE Okcode 20050405

Method OKCODE_HANDLER on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method PRINT_DEVICE_LIST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADDINF Value transfer Type reference (TYPE) RCGADDINF EHS: Zusatzinfos für FB-Aufrufe 20050405
2 Importing I_MPDV_IOTAB Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405
3 Importing I_MP_IOREC Value transfer Type reference (TYPE) CCIHS_MPIOT EHS: IOTAB für Messprojekte (CCIHT_MP) 20050405

Method PRINT_DEVICE_LIST on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method PUT_DATA_PAI Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_FLG_CHANGE Call by reference Type reference (TYPE) ESP1_BOOLEAN Kennzeichen Daten geändert 20050405
2 Importing I_MPDV_IOTAB Call by reference Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405

Method PUT_DATA_PAI on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method PUT_DATA_PBO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADDINF Value transfer Type reference (TYPE) RCGADDINF EHS: Zusatzinfos für FB-Aufrufe 20050405
2 Importing I_MPDV_IOTAB Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405
3 Importing I_MP_IOREC Value transfer Type reference (TYPE) CCIHS_MPIOT EHS: IOTAB für Messprojekte (CCIHT_MP) 20050405
4 Importing I_RCGDIALCTR Value transfer Type reference (TYPE) RCGDIALCTR PP-SHE: Dialogkontrollstruktur 20050405

Method PUT_DATA_PBO on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Value transfer Type reference (TYPE) ESP1_BOOLEAN Kennz. Fehler beim Speichern 20050405

Method SAVE on Interface IF_EX_EHSI_MP_DV_SCR has no exception.

Method VALUE_REQUEST_DEVICE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADDINF Value transfer Type reference (TYPE) RCGADDINF EHS: Zusatzinfos für FB-Aufrufe 20050405
2 Importing I_FLG_MANY Value transfer Type reference (TYPE) ESP1_BOOLEAN EHS: Kennz. Mehrfachselektion 20050405
3 Importing I_MP_IOREC Value transfer Type reference (TYPE) CCIHS_MPIOT EHS: IOTAB für Messprojekte (CCIHT_MP) 20050405
4 Importing I_RCGDIALCTR Value transfer Type reference (TYPE) RCGDIALCTR PP-SHE: Dialogkontrollstruktur 20050405
5 Changing X_FLG_CHANGED Value transfer Type reference (TYPE) ESP1_BOOLEAN Kennzeichen Daten geändert 20050405
6 Changing X_MPDV_IOTAB Value transfer Type reference (TYPE) CCIHY_MPDVIOT EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) 20050405

Method VALUE_REQUEST_DEVICE on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
History
Last changed by/on SAP  20060208 
SAP Release Created in 600