SAP ABAP Interface IF_EX_EHSI_MP_DV_SCR (BAdI Interface IF_EX_EHSI_MP_DV_SCR)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
EHS-IHS (Application Component) Industrial Hygiene and Safety
⤷
CBIH (Package) EH&S: Industrial Hygiene and Safety
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DEF_IM_EHSI_MP_DV_SCR | Default Implementation for BAdI Definition EHSI_MP_DV_SCR | 20050407 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_EHSI_MP_DV_SCR | BAdI Class CL_EX_EHSI_MP_DV_SCR | 20050609 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_EHSI_MP_DV_SCR | Implementation Class for BAdI Impl. EHSI_MP_DV_SCR | 20050426 |
Properties
| Interface | IF_EX_EHSI_MP_DV_SCR | |
| Short Description | BAdI Interface IF_EX_EHSI_MP_DV_SCR |
General Data
| Package | CBIH | EH&S: Industrial Hygiene and Safety |
| Created | 20050405 | SAP |
| Last changed | 20060208 | SAP |
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | ESP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20050609 |
Friends
Interface IF_EX_EHSI_MP_DV_SCR has no friend.
Attributes
Interface IF_EX_EHSI_MP_DV_SCR has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Display Device Details | 20050405 | |
| 2 | Instance method | Public | Method | Read Screen Data at Event PAI | 20050405 | |
| 3 | Instance method | Public | Method | Read Screen Data at Event PBO | 20050405 | |
| 4 | Instance method | Public | Method | OK-Code Handler | 20050405 | |
| 5 | Instance method | Public | Method | Print Device List | 20050405 | |
| 6 | Instance method | Public | Method | Transfer Screen Data at Event PAI | 20050405 | |
| 7 | Instance method | Public | Method | Transfer Screen Data at Event PBO | 20050405 | |
| 8 | Instance method | Public | Method | Save Device List | 20050405 | |
| 9 | Instance method | Public | Method | Input Help for Devices | 20050405 |
Events
Interface IF_EX_EHSI_MP_DV_SCR has no event.
Types
Interface IF_EX_EHSI_MP_DV_SCR has no local type.
Method Signatures
Method CALL_DEVICE_DETAIL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050405 | |||
| 2 | I_MPDV_IOREC | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 | |||
| 3 | I_MP_IOREC | Value transfer | Type reference (TYPE) | CCIHS_MPIOT | EHS: IOTAB für Messprojekte (CCIHT_MP) | 20050405 | |||
| 4 | I_RCGDIALCTR | Value transfer | Type reference (TYPE) | RCGDIALCTR | PP-SHE: Dialogkontrollstruktur | 20050405 |
Method CALL_DEVICE_DETAIL on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method GET_DATA_PAI Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_CHANGE | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen Daten geändert | 20050405 | |||
| 2 | E_MPDV_IOTAB | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 |
Method GET_DATA_PAI on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method GET_DATA_PBO Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050405 | |||
| 2 | E_MPDV_IOTAB | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 | |||
| 3 | E_MP_IOREC | Value transfer | Type reference (TYPE) | CCIHS_MPIOT | EHS: IOTAB für Messprojekte (CCIHT_MP) | 20050405 | |||
| 4 | E_RCGDIALCTR | Value transfer | Type reference (TYPE) | RCGDIALCTR | PP-SHE: Dialogkontrollstruktur | 20050405 |
Method GET_DATA_PBO on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method OKCODE_HANDLER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_OKCODE | Value transfer | Type reference (TYPE) | ESP1_OKCODE_TYPE | Okcode | 20050405 | |||
| 2 | I_OKCODE | Value transfer | Type reference (TYPE) | ESP1_OKCODE_TYPE | Okcode | 20050405 |
Method OKCODE_HANDLER on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method PRINT_DEVICE_LIST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050405 | |||
| 2 | I_MPDV_IOTAB | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 | |||
| 3 | I_MP_IOREC | Value transfer | Type reference (TYPE) | CCIHS_MPIOT | EHS: IOTAB für Messprojekte (CCIHT_MP) | 20050405 |
Method PRINT_DEVICE_LIST on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method PUT_DATA_PAI Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_FLG_CHANGE | Call by reference | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen Daten geändert | 20050405 | |||
| 2 | I_MPDV_IOTAB | Call by reference | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 |
Method PUT_DATA_PAI on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method PUT_DATA_PBO Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050405 | |||
| 2 | I_MPDV_IOTAB | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 | |||
| 3 | I_MP_IOREC | Value transfer | Type reference (TYPE) | CCIHS_MPIOT | EHS: IOTAB für Messprojekte (CCIHT_MP) | 20050405 | |||
| 4 | I_RCGDIALCTR | Value transfer | Type reference (TYPE) | RCGDIALCTR | PP-SHE: Dialogkontrollstruktur | 20050405 |
Method PUT_DATA_PBO on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method SAVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennz. Fehler beim Speichern | 20050405 |
Method SAVE on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
Method VALUE_REQUEST_DEVICE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050405 | |||
| 2 | I_FLG_MANY | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | EHS: Kennz. Mehrfachselektion | 20050405 | |||
| 3 | I_MP_IOREC | Value transfer | Type reference (TYPE) | CCIHS_MPIOT | EHS: IOTAB für Messprojekte (CCIHT_MP) | 20050405 | |||
| 4 | I_RCGDIALCTR | Value transfer | Type reference (TYPE) | RCGDIALCTR | PP-SHE: Dialogkontrollstruktur | 20050405 | |||
| 5 | X_FLG_CHANGED | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen Daten geändert | 20050405 | |||
| 6 | X_MPDV_IOTAB | Value transfer | Type reference (TYPE) | CCIHY_MPDVIOT | EHS: Tabellentyp für Geräte des Messprojekts (CCIHT_MPDV) | 20050405 |
Method VALUE_REQUEST_DEVICE on Interface IF_EX_EHSI_MP_DV_SCR has no exception.
History
| Last changed by/on | SAP | 20060208 |
| SAP Release Created in | 600 |