SAP ABAP Interface IF_EX_EHSH_BC_DET_SCR (BAdI Interface: EHSH_BC_DET_SCR)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
EHS-HEA (Application Component) Occupational Health
⤷
P99Q1 (Package) EH&S: Occupational Health

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_EHSH_BC_DET_SCR_BC01 | EHS: Class for Screen BAdI EHSH_BC_DET_SCR | 20050420 |
Properties
Interface | IF_EX_EHSH_BC_DET_SCR | |
Short Description | BAdI Interface: EHSH_BC_DET_SCR |
General Data
Package | P99Q1 | EH&S: Occupational Health |
Created | 20050331 | SAP |
Last changed | 20050428 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ESP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20050331 |
Friends
Interface IF_EX_EHSH_BC_DET_SCR has no friend.
Attributes
Interface IF_EX_EHSH_BC_DET_SCR has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Get Data at Event PAI | 20050331 |
2 | ![]() |
Instance method | Public | Method | Get Data at Event PBO | 20050331 |
3 | ![]() |
Instance method | Public | Method | Get OK Code at Event PAI for Subscreen | 20050421 |
4 | ![]() |
Instance method | Public | Method | Write Data at Event PAI | 20050331 |
5 | ![]() |
Instance method | Public | Method | Write Data at Event PBO | 20050331 |
6 | ![]() |
Instance method | Public | Method | Write OK Code at Event PAI for Main Screen | 20050421 |
7 | ![]() |
Instance method | Public | Method | Save of Changed Data | 20050331 |
Events
Interface IF_EX_EHSH_BC_DET_SCR has no event.
Types
Interface IF_EX_EHSH_BC_DET_SCR has no local type.
Method Signatures
Method GET_DATA_PAI Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_FLG_CHANGED | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen für Änderungen an Daten | 20050331 | ||
2 | ![]() |
E_FLG_SAVE_PEND | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen ob Daten gespeichert werden müssen | 20050331 | ||
3 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | EHS00E_BRCO_CAT | Kategorisierung von Kurzkontakten | 20050331 |
Method GET_DATA_PAI on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method GET_DATA_PBO Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_ACTYPE | Value transfer | Type reference (TYPE) | ACTYPE | Aktivitätstyp | 20050331 | ||
2 | ![]() |
E_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050331 | ||
3 | ![]() |
E_PERSON_IOREC | Value transfer | Type reference (TYPE) | EHS00S_PERS_SEL | EHS: Datenstruktur für Personenselektion | 20050331 | ||
4 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | EHS00E_BRCO_CAT | Kategorisierung von Kurzkontakten | 20050331 |
Method GET_DATA_PBO on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method GET_OKCODE_PAI Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_OKCODE | Call by reference | Type reference (TYPE) | SYUCOMM | Funktionscode, der PAI ausgelöst hat | 20050421 |
Method GET_OKCODE_PAI on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method PUT_DATA_PAI Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | EHS00E_BRCO_CAT | Kategorisierung von Kurzkontakten | 20050331 | ||
2 | ![]() |
I_FLG_CHANGED | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen für Änderungen an Daten | 20050331 | ||
3 | ![]() |
I_FLG_SAVE_PEND | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | Kennzeichen ob Daten gespeichert werden müssen | 20050331 |
Method PUT_DATA_PAI on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method PUT_DATA_PBO Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | EHS00E_BRCO_CAT | Kategorisierung von Kurzkontakten | 20050331 | ||
2 | ![]() |
I_ACTYPE | Value transfer | Type reference (TYPE) | ACTYPE | Aktivitätstyp | 20050331 | ||
3 | ![]() |
I_ADDINF | Value transfer | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050331 | ||
4 | ![]() |
I_PERSON_IOREC | Value transfer | Type reference (TYPE) | EHS00S_PERS_SEL | EHS: Datenstruktur für Personenselektion | 20050331 |
Method PUT_DATA_PBO on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method PUT_OKCODE_PAI Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_OKCODE | Call by reference | Type reference (TYPE) | SYUCOMM | Funktionscode, der PAI ausgelöst hat | 20050421 |
Method PUT_OKCODE_PAI on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
Method SAVE_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
FLT_VAL | Value transfer | Type reference (TYPE) | EHS00E_BRCO_CAT | Kategorisierung von Kurzkontakten | 20050331 | ||
2 | ![]() |
X_FLG_SAVE_PEND | Call by reference | Type reference (TYPE) | ESP1_BOOLEAN | 20050426 |
Method SAVE_DATA on Interface IF_EX_EHSH_BC_DET_SCR has no exception.
History
Last changed by/on | SAP | 20050428 |
SAP Release Created in | 600 |