SAP ABAP Interface IF_EX_ECM_IPPE_DECO (BAdI Interface IF_EX_ECM_IPPE_DECO)
Hierarchy
☛
SAP_ABA (Software Component) Cross-Application Component
⤷
CA-GTF-ECM (Application Component) Engineering Change Management
⤷
CC (Package) Engineering Change Management

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DI_ECM_DECOUPLING | BAdI Implementation from ECM (2) | 20020903 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_ECM_IPPE_DECO | BAdI Class CL_EX_ECM_IPPE_DECO | 20011016 |
3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_R3E_ECM_DECOUPLING | BAdI Implementation from ECM (2) | 20011108 |
Properties
Interface | IF_EX_ECM_IPPE_DECO | |
Short Description | BAdI Interface IF_EX_ECM_IPPE_DECO |
General Data
Package | CC | Engineering Change Management |
Created | 20011016 | SAP |
Last changed | 20011017 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | CC01 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_EX_ECM_IPPE_DECO has no interface.
Friends
Interface IF_EX_ECM_IPPE_DECO has no friend.
Attributes
Interface IF_EX_ECM_IPPE_DECO has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Change Number Used in iPPE | 20011016 |
2 | ![]() |
Instance method | Public | Method | Read iPPE Customizing | 20011016 |
3 | ![]() |
Instance method | Public | Method | iPPE GUID Exists | 20011016 |
4 | ![]() |
Instance method | Public | Method | GUID Conversion from External to Internal | 20011016 |
5 | ![]() |
Instance method | Public | Method | GUID Conversion from Internal to External | 20011016 |
6 | ![]() |
Instance method | Public | Method | iPPE Status Allows Release of Change Number | 20011016 |
7 | ![]() |
Instance method | Public | Method | Read iPPE Description | 20011016 |
8 | ![]() |
Instance method | Public | Method | iPPE Transaction Call | 20011016 |
Events
Interface IF_EX_ECM_IPPE_DECO has no event.
Types
Interface IF_EX_ECM_IPPE_DECO has no local type.
Method Signatures
Method IPPE_AENNR_CHK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_AENNR | Call by reference | Type reference (TYPE) | AENNR | Änderungsnummer | 20011016 | ||
2 | ![]() |
I_AETYP | Call by reference | Type reference (TYPE) | AETYP | Objekttyp | 20011016 | ||
3 | ![]() |
I_OBJKT | Call by reference | Type reference (TYPE) | AEOBJEKT | Identifikation des zu ändernden Objektes | 20011016 | ||
4 | ![]() |
O_IS_USED | Call by reference | Type reference (TYPE) | XFELD | Objekt benutzt diese Änderungsnummer | 20011016 |
Method IPPE_AENNR_CHK on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_CUSTOMIZING_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
O_EFFPARAM | Call by reference | Type reference (TYPE) | CC_EFFP | Gültigkeit: definierender Parameter | 20011016 | ||
2 | ![]() |
O_EFFPARAM_FIELD | Call by reference | Type reference (TYPE) | CHAR100 | Effectivity: Name eines Gültigkeitparameters | 20011016 | ||
3 | ![]() |
O_EXPL_OPTION | Call by reference | Type reference (TYPE) | CHAR1 | Auflösungssteuerung für Varianten und Modi | 20011016 |
Method IPPE_CUSTOMIZING_READ on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_GUID_EXISTENCE_CHK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_GUID | Call by reference | Type reference (TYPE) | SYSUUID_C | UUID in Character-Darstellung | 20011016 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20011016 |
Method IPPE_GUID_EXT_TO_INT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_CLASS | Call by reference | Type reference (TYPE) | KLASSE_D | Klassennummer | 20011016 | ||
2 | ![]() |
I_KLART | Call by reference | Type reference (TYPE) | KLASSENART | Klassenart | 20011016 | ||
3 | ![]() |
I_PNAME | Call by reference | Type reference (TYPE) | CC_PVS_PNODE | Änderungsdienst: PVS-Knoten | 20011016 | ||
4 | ![]() |
I_PVNAME | Call by reference | Type reference (TYPE) | CC_PVS_POSVAR | Änderungsdienst: PVS-Variante | 20011016 | ||
5 | ![]() |
O_FLG_EXIST | Call by reference | Type reference (TYPE) | XFELD | Flag: PVS-Variante existiert | 20020423 | ||
6 | ![]() |
O_GUID | Call by reference | Type reference (TYPE) | SYSUUID_C | UUID in Character-Darstellung | 20011016 |
Method IPPE_GUID_EXT_TO_INT on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_GUID_INT_TO_EXT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_AETYP | Call by reference | Type reference (TYPE) | AETYP | Objekttyp | 20011016 | ||
2 | ![]() |
I_GUID | Call by reference | Type reference (TYPE) | SYSUUID_C | UUID in Character-Darstellung | 20011016 | ||
3 | ![]() |
O_CLASS | Call by reference | Type reference (TYPE) | KLASSE_D | Klassennummer | 20011016 | ||
4 | ![]() |
O_FLG_EXIST | Call by reference | Type reference (TYPE) | XFELD | Flag: PVS Variante existiert | 20020218 | ||
5 | ![]() |
O_KLART | Call by reference | Type reference (TYPE) | KLASSENART | Klassenart | 20011016 | ||
6 | ![]() |
O_PNAME | Call by reference | Type reference (TYPE) | CC_PVS_PNODE | Änderungsdienst: PVS-Knoten | 20011016 | ||
7 | ![]() |
O_PVNAME | Call by reference | Type reference (TYPE) | CC_PVS_POSVAR | Änderungsdienst: PVS-Variante | 20011016 |
Method IPPE_GUID_INT_TO_EXT on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_STATUS_CHK_RELKEY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_AENNR | Call by reference | Type reference (TYPE) | AENNR | Änderungsnummer | 20011016 | ||
2 | ![]() |
I_RLKEY | Call by reference | Type reference (TYPE) | CC_RLKEY | Freigabeschlüssel für Änderungsstammsatz | 20011016 | ||
3 | ![]() |
O_ERROR | Call by reference | Type reference (TYPE) | XFELD | Fehler | 20011016 | ||
4 | ![]() |
O_MSGID | Call by reference | Type reference (TYPE) | SYMSGID | Nachrichten, Nachrichtenklasse | 20011016 | ||
5 | ![]() |
O_MSGNO | Call by reference | Type reference (TYPE) | SYMSGNO | Nachrichten, Nachrichtennummer | 20011016 | ||
6 | ![]() |
O_MSGTY | Call by reference | Type reference (TYPE) | SYMSGTY | Nachrichten, Nachrichtentyp | 20011016 | ||
7 | ![]() |
O_MSGV1 | Call by reference | Type reference (TYPE) | SYMSGV | Nachrichten, Nachrichtenvariable | 20011016 | ||
8 | ![]() |
O_MSGV2 | Call by reference | Type reference (TYPE) | SYMSGV | Nachrichten, Nachrichtenvariable | 20011016 | ||
9 | ![]() |
O_MSGV3 | Call by reference | Type reference (TYPE) | SYMSGV | Nachrichten, Nachrichtenvariable | 20011016 | ||
10 | ![]() |
O_MSGV4 | Call by reference | Type reference (TYPE) | SYMSGV | Nachrichten, Nachrichtenvariable | 20011016 |
Method IPPE_STATUS_CHK_RELKEY on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_TEXT_READ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_CLASS | Call by reference | Type reference (TYPE) | KLASSE_D | Klassennummer | 20011016 | ||
2 | ![]() |
I_KLART | Call by reference | Type reference (TYPE) | KLASSENART | Klassenart | 20011016 | ||
3 | ![]() |
I_PNAME | Call by reference | Type reference (TYPE) | CC_PVS_PNODE | Änderungsdienst: PVS-Knoten | 20011016 | ||
4 | ![]() |
I_PVNAME | Call by reference | Type reference (TYPE) | CC_PVS_POSVAR | Änderungsdienst: PVS-Variante | 20011016 | ||
5 | ![]() |
O_PVSTXT | Call by reference | Type reference (TYPE) | CC_PVSTXT | Beschreibung Produkt Varianten Struktur | 20011016 |
Method IPPE_TEXT_READ on Interface IF_EX_ECM_IPPE_DECO has no exception.
Method IPPE_TRANSACTION_CALL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_ACTIVITY | Call by reference | Type reference (TYPE) | CHAR1 | Aktivität der Transaktion | 20011016 | ||
2 | ![]() |
I_AENNR | Call by reference | Type reference (TYPE) | AENNR | Änderungsnummer | 20020709 | ||
3 | ![]() |
I_CLASS | Call by reference | Type reference (TYPE) | KLASSE_D | Klassennummer | 20011016 | ||
4 | ![]() |
I_KLART | Call by reference | Type reference (TYPE) | KLASSENART | Klassenart | 20011016 | ||
5 | ![]() |
I_PNAME | Call by reference | Type reference (TYPE) | CC_PVS_PNODE | Änderungsdienst: PVS-Knoten | 20011016 | ||
6 | ![]() |
I_PVNAME | Call by reference | Type reference (TYPE) | CC_PVS_POSVAR | Änderungsdienst: PVS-Variante | 20011016 |
Method IPPE_TRANSACTION_CALL on Interface IF_EX_ECM_IPPE_DECO has no exception.
History
Last changed by/on | SAP | 20011017 |
SAP Release Created in | 620 |