SAP ABAP Interface IF_EX_ECM_IPPE_DECO (BAdI Interface IF_EX_ECM_IPPE_DECO)
Hierarchy
SAP_ABA (Software Component) Cross-Application Component
   CA-GTF-ECM (Application Component) Engineering Change Management
     CC (Package) Engineering Change Management
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_DI_ECM_DECOUPLING BAdI Implementation from ECM (2) 20020903
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_ECM_IPPE_DECO BAdI Class CL_EX_ECM_IPPE_DECO 20011016
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_R3E_ECM_DECOUPLING BAdI Implementation from ECM (2) 20011108
Properties
Interface IF_EX_ECM_IPPE_DECO  
Short Description BAdI Interface IF_EX_ECM_IPPE_DECO    
General Data
Package CC   Engineering Change Management 
Created 20011016   SAP 
Last changed 20011017   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 CC01 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface IF_EX_ECM_IPPE_DECO has no interface.
Friends
Interface IF_EX_ECM_IPPE_DECO has no friend.
Attributes
Interface IF_EX_ECM_IPPE_DECO has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 IPPE_AENNR_CHK Instance method Public Method Change Number Used in iPPE 20011016
2 IPPE_CUSTOMIZING_READ Instance method Public Method Read iPPE Customizing 20011016
3 IPPE_GUID_EXISTENCE_CHK Instance method Public Method iPPE GUID Exists 20011016
4 IPPE_GUID_EXT_TO_INT Instance method Public Method GUID Conversion from External to Internal 20011016
5 IPPE_GUID_INT_TO_EXT Instance method Public Method GUID Conversion from Internal to External 20011016
6 IPPE_STATUS_CHK_RELKEY Instance method Public Method iPPE Status Allows Release of Change Number 20011016
7 IPPE_TEXT_READ Instance method Public Method Read iPPE Description 20011016
8 IPPE_TRANSACTION_CALL Instance method Public Method iPPE Transaction Call 20011016
Events
Interface IF_EX_ECM_IPPE_DECO has no event.
Types
Interface IF_EX_ECM_IPPE_DECO has no local type.
Method Signatures

Method IPPE_AENNR_CHK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20011016
2 Importing I_AETYP Call by reference Type reference (TYPE) AETYP Objekttyp 20011016
3 Importing I_OBJKT Call by reference Type reference (TYPE) AEOBJEKT Identifikation des zu ändernden Objektes 20011016
4 Exporting O_IS_USED Call by reference Type reference (TYPE) XFELD Objekt benutzt diese Änderungsnummer 20011016

Method IPPE_AENNR_CHK on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_CUSTOMIZING_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting O_EFFPARAM Call by reference Type reference (TYPE) CC_EFFP Gültigkeit: definierender Parameter 20011016
2 Exporting O_EFFPARAM_FIELD Call by reference Type reference (TYPE) CHAR100 Effectivity: Name eines Gültigkeitparameters 20011016
3 Exporting O_EXPL_OPTION Call by reference Type reference (TYPE) CHAR1 Auflösungssteuerung für Varianten und Modi 20011016

Method IPPE_CUSTOMIZING_READ on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_GUID_EXISTENCE_CHK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_GUID Call by reference Type reference (TYPE) SYSUUID_C UUID in Character-Darstellung 20011016
# Exception Resumable Description Created on
1 NOT_FOUND 20011016

Method IPPE_GUID_EXT_TO_INT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CLASS Call by reference Type reference (TYPE) KLASSE_D Klassennummer 20011016
2 Importing I_KLART Call by reference Type reference (TYPE) KLASSENART Klassenart 20011016
3 Importing I_PNAME Call by reference Type reference (TYPE) CC_PVS_PNODE Änderungsdienst: PVS-Knoten 20011016
4 Importing I_PVNAME Call by reference Type reference (TYPE) CC_PVS_POSVAR Änderungsdienst: PVS-Variante 20011016
5 Exporting O_FLG_EXIST Call by reference Type reference (TYPE) XFELD Flag: PVS-Variante existiert 20020423
6 Exporting O_GUID Call by reference Type reference (TYPE) SYSUUID_C UUID in Character-Darstellung 20011016

Method IPPE_GUID_EXT_TO_INT on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_GUID_INT_TO_EXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AETYP Call by reference Type reference (TYPE) AETYP Objekttyp 20011016
2 Importing I_GUID Call by reference Type reference (TYPE) SYSUUID_C UUID in Character-Darstellung 20011016
3 Exporting O_CLASS Call by reference Type reference (TYPE) KLASSE_D Klassennummer 20011016
4 Exporting O_FLG_EXIST Call by reference Type reference (TYPE) XFELD Flag: PVS Variante existiert 20020218
5 Exporting O_KLART Call by reference Type reference (TYPE) KLASSENART Klassenart 20011016
6 Exporting O_PNAME Call by reference Type reference (TYPE) CC_PVS_PNODE Änderungsdienst: PVS-Knoten 20011016
7 Exporting O_PVNAME Call by reference Type reference (TYPE) CC_PVS_POSVAR Änderungsdienst: PVS-Variante 20011016

Method IPPE_GUID_INT_TO_EXT on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_STATUS_CHK_RELKEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20011016
2 Importing I_RLKEY Call by reference Type reference (TYPE) CC_RLKEY Freigabeschlüssel für Änderungsstammsatz 20011016
3 Exporting O_ERROR Call by reference Type reference (TYPE) XFELD Fehler 20011016
4 Exporting O_MSGID Call by reference Type reference (TYPE) SYMSGID Nachrichten, Nachrichtenklasse 20011016
5 Exporting O_MSGNO Call by reference Type reference (TYPE) SYMSGNO Nachrichten, Nachrichtennummer 20011016
6 Exporting O_MSGTY Call by reference Type reference (TYPE) SYMSGTY Nachrichten, Nachrichtentyp 20011016
7 Exporting O_MSGV1 Call by reference Type reference (TYPE) SYMSGV Nachrichten, Nachrichtenvariable 20011016
8 Exporting O_MSGV2 Call by reference Type reference (TYPE) SYMSGV Nachrichten, Nachrichtenvariable 20011016
9 Exporting O_MSGV3 Call by reference Type reference (TYPE) SYMSGV Nachrichten, Nachrichtenvariable 20011016
10 Exporting O_MSGV4 Call by reference Type reference (TYPE) SYMSGV Nachrichten, Nachrichtenvariable 20011016

Method IPPE_STATUS_CHK_RELKEY on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_TEXT_READ Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CLASS Call by reference Type reference (TYPE) KLASSE_D Klassennummer 20011016
2 Importing I_KLART Call by reference Type reference (TYPE) KLASSENART Klassenart 20011016
3 Importing I_PNAME Call by reference Type reference (TYPE) CC_PVS_PNODE Änderungsdienst: PVS-Knoten 20011016
4 Importing I_PVNAME Call by reference Type reference (TYPE) CC_PVS_POSVAR Änderungsdienst: PVS-Variante 20011016
5 Exporting O_PVSTXT Call by reference Type reference (TYPE) CC_PVSTXT Beschreibung Produkt Varianten Struktur 20011016

Method IPPE_TEXT_READ on Interface IF_EX_ECM_IPPE_DECO has no exception.

Method IPPE_TRANSACTION_CALL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ACTIVITY Call by reference Type reference (TYPE) CHAR1 Aktivität der Transaktion 20011016
2 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20020709
3 Importing I_CLASS Call by reference Type reference (TYPE) KLASSE_D Klassennummer 20011016
4 Importing I_KLART Call by reference Type reference (TYPE) KLASSENART Klassenart 20011016
5 Importing I_PNAME Call by reference Type reference (TYPE) CC_PVS_PNODE Änderungsdienst: PVS-Knoten 20011016
6 Importing I_PVNAME Call by reference Type reference (TYPE) CC_PVS_POSVAR Änderungsdienst: PVS-Variante 20011016

Method IPPE_TRANSACTION_CALL on Interface IF_EX_ECM_IPPE_DECO has no exception.
History
Last changed by/on SAP  20011017 
SAP Release Created in 620