SAP ABAP Interface IF_EX_BADI_WCM_WCTM (Interface for BAdI: BADI_WCM_WCTM)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   PM-WCM (Application Component) Work Clearance Management
     WCM (Package) WCM: Work Clearance Management
Properties
Interface IF_EX_BADI_WCM_WCTM  
Short Description Interface for BAdI: BADI_WCM_WCTM    
General Data
Package WCM   WCM: Work Clearance Management 
Created 20070730   SAP 
Last changed 20130531   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 WCTP1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 WCTP3 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 WCTPC Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 WCTPP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
# Interface Abstract Final Description Created on
1 IF_BADI_INTERFACE Tag Interface for BAdIs 20070730
Friends
Interface IF_EX_BADI_WCM_WCTM has no friend.
Attributes
Interface IF_EX_BADI_WCM_WCTM has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 COPY_MODEL_REDUCE Instance method Public Method Restrict Items in Template To Be Copied 20100201
2 GRAPHICAL_SYSTEM_MODIFY Instance method Public Method Revise Data 20070801
3 ITEM_DATA_INPUT_CHECK Instance method Public Method General Entry Check 20111104
4 ITEM_STATUS_INAC_CHECK Instance method Public Method Check Whether Item Can Be Deactivated 20070730
5 PASTE_REDUCE Instance method Public Method Restrict Insertion from the Clipboard 20120301
6 PHBLNR_INPUT_CHECK Instance method Public Method Input Check for Lock (Physical Blocking) 20070822
7 PHBLNR_VALUE_HELP Instance method Public Method Input Help for Lock (Physical Blocking) 20070822
8 PREPARED_CHECK Instance method Public Method Check Setting of Status "Prepared" 20070730
9 RFC_DESTINATION_GET Instance method Public Method Change Logical Destination 20070801
10 SELECTION_MODIFY Instance method Public Method Revise Selection 20070730
11 SIMULATION Instance method Public Method Simulation on Maintenance Screen 20070730
12 SORT Instance method Public Method Sort Items on Maintenance Screen 20070730
13 USRFLD_GET Instance method Public Method Set User Field 20070730
Events
Interface IF_EX_BADI_WCM_WCTM has no event.
Types
Interface IF_EX_BADI_WCM_WCTM has no local type.
Method Signatures

Method COPY_MODEL_REDUCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_WCAIT Value transfer Type reference (TYPE) WCTP1_WCAITTAB_TYPE Einschränkungen 20100201
2 Importing IT_WCAIT Value transfer Type reference (TYPE) WCTP1_WCAITTAB_TYPE Auswahlmenge 20100201
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20100201
4 Importing IV_REFWC Value transfer Type reference (TYPE) WCEREFWC Freischaltliste (Vorlage) 20100201

Method COPY_MODEL_REDUCE on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method GRAPHICAL_SYSTEM_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_ITM Value transfer Type reference (TYPE) RFC_WCDITM_DATATAB Daten der übergebenen Positionen 20070801
2 Importing IT_HDR Value transfer Type reference (TYPE) RFC_WCD_DATA Kopfdaten der Freischaltliste 20071010
3 Importing IT_HDR_STATUS Value transfer Type reference (TYPE) RFC_WCD_STATUS Status der Freischaltliste 20071010
4 Importing IT_ITM_INSCTRL Value transfer Type reference (TYPE) RFC_WCDITM_CTRL Pflegekennzeichen für neue Positionen 20071010
5 Importing IT_ITM_STATUS Value transfer Type reference (TYPE) RFC_WCDITM_STATUSTAB Status der Positionen 20071010
6 Importing IT_ITM_UPDCTRL Value transfer Type reference (TYPE) RFC_WCDITM_UPDCTRLTAB Pflegekennzeichen für übergebene Positionen 20071010
7 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070801
8 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070801
9 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070801
10 Importing IV_POINT_OF_TIME Value transfer Type reference (TYPE) WCETIMEPOINT Zeitpunkt 20070815

Method GRAPHICAL_SYSTEM_MODIFY on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method ITEM_DATA_INPUT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20111104
2 Importing IS_ITM Value transfer Type reference (TYPE) WCSWCITM Struktur: Positionen 20111104
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20111104
4 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20111104
5 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111104

Method ITEM_DATA_INPUT_CHECK on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method ITEM_STATUS_INAC_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070730
2 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
3 Importing IV_ITM_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Position) 20070730
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730

Method ITEM_STATUS_INAC_CHECK on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method PASTE_REDUCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_DELETE Value transfer Type reference (TYPE) WCTPC_INDEXTAB_TYPE Tabelle der zu löschenden Einträge 20120301
2 Importing IT_CLIPBOARD Value transfer Type reference (TYPE) WCTP1_WCITMTAB_TYPE Zwischenablage 20120301
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120301
4 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20120301
5 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120301

Method PASTE_REDUCE on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method PHBLNR_INPUT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070822
2 Importing IS_ITM Value transfer Type reference (TYPE) WCSWCITM Struktur: Positionen 20070823
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070822
4 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070822
5 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070822

Method PHBLNR_INPUT_CHECK on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method PHBLNR_VALUE_HELP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_PHBLNR Value transfer Type reference (TYPE) WCEPHBLNR Schloss 20070823
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070822
3 Importing IV_CCOBJ Value transfer Type reference (TYPE) WCECCOBJ Technisches Objekt 20070823
4 Importing IV_CCTYP Value transfer Type reference (TYPE) WCECCTYP Typ der Position 20070823
5 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070822
6 Importing IV_ITM_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Position) 20070822
7 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070822
8 Importing IV_TGGRP Value transfer Type reference (TYPE) WCETGGRP Schaltgruppe 20070823

Method PHBLNR_VALUE_HELP on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method PREPARED_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070730
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070730
3 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
4 Importing IV_INFO Value transfer Type reference (TYPE) WCEINFO Meldung kann ausgegeben werden 20110811
5 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730

Method PREPARED_CHECK on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method RFC_DESTINATION_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_RFCDEST Value transfer Type reference (TYPE) RFCDEST RFC-Destination 20110616
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070801
3 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070801
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070801

Method RFC_DESTINATION_GET on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method SELECTION_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_CCOBJ Value transfer Type reference (TYPE) WCTPC_CCOBJTAB_TYPE Tabelle von technischen Objekten 20070730
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070730
3 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730

Method SELECTION_MODIFY on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method SIMULATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070730
2 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730

Method SIMULATION on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method SORT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_SORT Value transfer Type reference (TYPE) ABAP_SORTORDER_TAB Tabelle für SORT itab BY (ABAP_SORTORDER_TAB) 20070730
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070730
3 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730

Method SORT on Interface IF_EX_BADI_WCM_WCTM has no exception.

Method USRFLD_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_USRFLD Value transfer Type reference (TYPE) WCTP1_USRFLD_TYPE Benutzerfeld 20070730
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070730
3 Importing IV_HDR_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Kopf) 20070730
4 Importing IV_ITM_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer (Position) 20070730
5 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070730
6 Importing IV_SCREEN Value transfer Type reference (TYPE) SYDYNNR Aktuelle Dynpro-Nummer 20070730

Method USRFLD_GET on Interface IF_EX_BADI_WCM_WCTM has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 603