Hierarchy

⤷

⤷

Properties
Interface | IF_EX_BADI_WCM_WCMOBJ_SAP | |
Short Description | Interface for BAdI: BADI_WCM_WCMOBJ |
General Data
Package | WCM | WCM: Work Clearance Management |
Created | 20120924 | SAP |
Last changed | 20130531 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | WCTP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | WCTP3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | WCTPC | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | WCTPD | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
5 | WCTPF | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
6 | WCTPP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20120924 |
Friends
Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no friend.
Attributes
Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Final Tasks While Terminating | 20120924 |
2 | ![]() |
Instance method | Public | Method | Changes to Additional Data Forbidden | 20120924 |
3 | ![]() |
Instance method | Public | Method | Check Creation with Template | 20120924 |
4 | ![]() |
Instance method | Public | Method | Deactivate Function Codes | 20120924 |
5 | ![]() |
Instance method | Public | Method | Check Authorization for a Function | 20120924 |
6 | ![]() |
Instance method | Public | Method | Set Pushbutton Text for Printing | 20120924 |
7 | ![]() |
Instance method | Public | Method | Deactivate Functions of Set GUI Status | 20120924 |
8 | ![]() |
Instance method | Public | Method | Final Work During Initialization | 20120924 |
9 | ![]() |
Instance method | Public | Method | Set Planning Data | 20120924 |
10 | ![]() |
Instance method | Public | Method | Check Printing of Header Data | 20120924 |
11 | ![]() |
Instance method | Public | Method | Check Printing of Work Permit | 20120924 |
12 | ![]() |
Instance method | Public | Method | Check Save | 20120924 |
13 | ![]() |
Instance method | Public | Method | Final Tasks While Saving | 20120924 |
14 | ![]() |
Instance method | Public | Method | Check Setting of Status "Change Mode" | 20120924 |
15 | ![]() |
Instance method | Public | Method | Check Setting of Status "Closed" | 20120924 |
16 | ![]() |
Instance method | Public | Method | Check Setting of Status "Deletion Flag Set" | 20120924 |
17 | ![]() |
Instance method | Public | Method | Check Setting of Status "Inactive" | 20120924 |
18 | ![]() |
Instance method | Public | Method | Check Setting of Status "Prepared" | 20120924 |
19 | ![]() |
Instance method | Public | Method | Check Setting of Status "Rejected" | 20120924 |
20 | ![]() |
Instance method | Public | Method | Check Revoking of Status "Deletion Flag Set" | 20120924 |
21 | ![]() |
Instance method | Public | Method | Check Revoking of Status "Inactive" | 20120924 |
22 | ![]() |
Instance method | Public | Method | Set Change Indicator | 20120924 |
23 | ![]() |
Instance method | Public | Method | Set User Field | 20120924 |
Events
Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no event.
Types
Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no local type.
Method Signatures
Method CANCEL_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
2 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
3 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method CANCEL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method CHANGES_FORBIDDEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_BLST | Value transfer | Type reference (TYPE) | WCTP1_UPDBLSTTAB_TYPE | Einschränkende Status | 20120924 | ||
2 | ![]() |
IV_ADDITIONAL_DATA | Value transfer | Type reference (TYPE) | WCEIF | Zusatzdaten | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method CHANGES_FORBIDDEN on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method COPY_MODEL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IS_REF_ORDER | Value transfer | Type reference (TYPE) | WCTP1_ORDERWA_TYPE | Struktur: Auftrag | 20120924 | ||
3 | ![]() |
IS_REF_WCAAP | Value transfer | Type reference (TYPE) | WCTP1_WCAAPWA_TYPE | Struktur: Anforderung | 20120924 | ||
4 | ![]() |
IS_REF_WCAHE | Value transfer | Type reference (TYPE) | WCTP1_WCAHEWA_TYPE | Struktur: Freischaltliste | 20120924 | ||
5 | ![]() |
IS_REF_WCAW | Value transfer | Type reference (TYPE) | WCTP1_WCAWWA_TYPE | Struktur: Arbeitsgenehmigung | 20120924 | ||
6 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
7 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
8 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 | ||
9 | ![]() |
IV_REF_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart (Vorlage) | 20120924 |
Method COPY_MODEL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method FCODE_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20120924 | ||
2 | ![]() |
IT_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20120924 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
5 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
6 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
7 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method FUNCTION_AUTHORIZATION_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_FCODE | Value transfer | Type reference (TYPE) | FCODE | Funktionscode | 20120924 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
5 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
6 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
7 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method FUNCTION_AUTHORIZATION_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method FUNCTION_TEXTS_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_DYNTXT_PRI | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Freischaltdokument drucken | 20120924 | ||
2 | ![]() |
CS_DYNTXT_PRI0 | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Arbeitserlaubnis drucken | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method FUNCTION_TEXTS_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method GUI_STATUS_FCODE_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20120924 | ||
2 | ![]() |
IT_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20120924 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
5 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
6 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
7 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method GUI_STATUS_FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method INIT_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
2 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
3 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method INIT_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method PLANNING_DATA_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ES_ACTUAL_DATES | Value transfer | Type reference (TYPE) | WCSACTUAL_DATES | Struktur: Isttermin | 20120924 | ||
2 | ![]() |
ES_BASIC_DATES | Value transfer | Type reference (TYPE) | WCSBASIC_DATES | Struktur: Ecktermin | 20120924 | ||
3 | ![]() |
ES_SCHEDULED_DATES | Value transfer | Type reference (TYPE) | WCSSCHEDULED_DATES | Struktur: Terminiert | 20120924 | ||
4 | ![]() |
IS_ACTUAL_DATES | Value transfer | Type reference (TYPE) | WCSACTUAL_DATES | Struktur: Isttermin | 20120924 | ||
5 | ![]() |
IS_BASIC_DATES | Value transfer | Type reference (TYPE) | WCSBASIC_DATES | Struktur: Ecktermin | 20120924 | ||
6 | ![]() |
IS_SCHEDULED_DATES | Value transfer | Type reference (TYPE) | WCSSCHEDULED_DATES | Struktur: Terminiert | 20120924 | ||
7 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
8 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
9 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
10 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
11 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method PLANNING_DATA_GET on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method PRINT_HEADER_DATA_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method PRINT_HEADER_DATA_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method PRINT_WORK_PERMIT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_COPYFLG | Value transfer | Type reference (TYPE) | WCECOPYFLG | Kennzeichen: Kopie | 20120924 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
5 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
6 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
7 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method PRINT_WORK_PERMIT_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method SAVE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method SAVE_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method SAVE_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
2 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
3 | ![]() |
IV_NEWOBJ | Value transfer | Type reference (TYPE) | J_OBJNR | Neue Objektnummer | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJKEY | Value transfer | Type reference (TYPE) | WCENO | Schlüssel | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 | ||
7 | ![]() |
IV_OLDOBJ | Value transfer | Type reference (TYPE) | J_OBJNR | Alte Objektnummer | 20120924 |
Method SAVE_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_CHGN_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_CHGN_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_CLSD_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_INFO | Value transfer | Type reference (TYPE) | WCEINFO | Booelscher Wert: Meldung kann ausgeben werden | 20120924 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
5 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
6 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
7 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_CLSD_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_DLFL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_INAC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_PREP_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_PREP_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_REJC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_REJC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_RESET_DLFL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_RESET_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method STATUS_RESET_INAC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method STATUS_RESET_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method UPDFLG_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_UPDFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Änderungskennzeichen | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method UPDFLG_GET on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
Method USRFLD_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_USRFLD | Value transfer | Type reference (TYPE) | WCTP1_USRFLD_TYPE | Benutzerfeld | 20120924 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120924 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120924 | ||
4 | ![]() |
IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120924 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120924 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120924 |
Method USRFLD_GET on Interface IF_EX_BADI_WCM_WCMOBJ_SAP has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 617 |