Hierarchy
⤷ PM-WCM (Application Component) Work Clearance Management
⤷ WCM (Package) WCM: Work Clearance Management
Properties
Interface | IF_EX_BADI_WCM_WCMOBJ | |
Short Description | Interface for BAdI: BADI_WCM_WCMOBJ |
General Data
Package | WCM | WCM: Work Clearance Management |
Created | 20070724 | SAP |
Last changed | 20140121 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | WCTP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | WCTP3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | WCTPC | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | WCTPD | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
5 | WCTPF | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
6 | WCTPP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20070724 |
Friends
Interface IF_EX_BADI_WCM_WCMOBJ has no friend.
Attributes
Interface IF_EX_BADI_WCM_WCMOBJ has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CANCEL_FINALIZE | Instance method | Public | Method | Final Tasks While Terminating | 20111121 |
2 | CHANGES_FORBIDDEN | Instance method | Public | Method | Changes to Additional Data Forbidden | 20111207 |
3 | COLOR_MODIFY | Instance method | Public | Method | Change Color | 20070822 |
4 | COPY_MODEL_CHECK | Instance method | Public | Method | Check Creation with Template | 20070724 |
5 | FCODE_DEACTIVATE | Instance method | Public | Method | Deactivate Function Codes | 20070724 |
6 | FUNCTION_AUTHORIZATION_CHECK | Instance method | Public | Method | Check Authorization for a Function | 20120921 |
7 | FUNCTION_TEXTS_MODIFY | Instance method | Public | Method | Set Pushbutton Text for Printing | 20110823 |
8 | GUI_STATUS_FCODE_DEACTIVATE | Instance method | Public | Method | Deactivate Functions of Set GUI Status | 20110807 |
9 | INIT_FINALIZE | Instance method | Public | Method | Final Work During Initialization | 20111207 |
10 | JOB_USER_GET | Instance method | Public | Method | Set User ID | 20100727 |
11 | PLANNING_DATA_GET | Instance method | Public | Method | Set Planning Data | 20070724 |
12 | PRINT_CONTROL_MODIFY | Instance method | Public | Method | Change Print Settings | 20110823 |
13 | PRINT_HEADER_DATA_CHECK | Instance method | Public | Method | Check Printing of Header Data | 20070724 |
14 | PRINT_WORK_PERMIT_CHECK | Instance method | Public | Method | Check Printing of Work Permit | 20070724 |
15 | SAVE_CHECK | Instance method | Public | Method | Check Save | 20070801 |
16 | SAVE_FINALIZE | Instance method | Public | Method | Final Tasks While Saving | 20111121 |
17 | STATUS_CHGN_CHECK | Instance method | Public | Method | Check Setting of Status "Change Mode" | 20070724 |
18 | STATUS_CHGN_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Change Mode" | 20120116 |
19 | STATUS_CLSD_CHECK | Instance method | Public | Method | Check Setting of Status "Closed" | 20070724 |
20 | STATUS_CLSD_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Closed" | 20120116 |
21 | STATUS_DLFL_CHECK | Instance method | Public | Method | Check Setting of Status "Deletion Flag Set" | 20070724 |
22 | STATUS_DLFL_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Deletion Flag Set" | 20120116 |
23 | STATUS_INAC_CHECK | Instance method | Public | Method | Check Setting of Status "Inactive" | 20070724 |
24 | STATUS_INAC_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Inactive" | 20120116 |
25 | STATUS_PREP_CHECK | Instance method | Public | Method | Check Setting of Status "Prepared" | 20070724 |
26 | STATUS_PREP_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Prepared" | 20120116 |
27 | STATUS_REJC_CHECK | Instance method | Public | Method | Check Setting of Status "Rejected" | 20070724 |
28 | STATUS_REJC_FINALIZE | Instance method | Public | Method | Work After Setting of Status "Rejected" | 20120116 |
29 | STATUS_RESET_DLFL_CHECK | Instance method | Public | Method | Check Revoking of Status "Deletion Flag Set" | 20070724 |
30 | STATUS_RESET_DLFL_FINALIZE | Instance method | Public | Method | Work After Resetting of Status "Deletion Flag Set" | 20120116 |
31 | STATUS_RESET_INAC_CHECK | Instance method | Public | Method | Check Revoking of Status "Inactive" | 20070724 |
32 | STATUS_RESET_INAC_FINALIZE | Instance method | Public | Method | Work After Resetting of Status "Inactive" | 20120116 |
33 | TEMPLATE_DISPLAY_REDUCE | Instance method | Public | Method | Restricted Template Assignments Displayed | 20111026 |
34 | TEMPLATE_FCODE_DEACTIVATE | Instance method | Public | Method | Deactivate Function Codes (Templates) | 20110907 |
35 | TEMPLATE_SEARCH_REPLACE | Instance method | Public | Method | Replaces the Selection of Templates for Assignment | 20110805 |
36 | TEXT_MODIFY | Instance method | Public | Method | Change Short Text | 20070822 |
37 | UPDFLG_GET | Instance method | Public | Method | Set Change Indicator | 20070924 |
38 | USAGE_MODIFY | Instance method | Public | Method | Change Usage | 20110803 |
39 | USRFLD_GET | Instance method | Public | Method | Set User Field | 20070724 |
40 | VIEWPROFILE_MODIFY | Instance method | Public | Method | Change View Profile | 20110528 |
Events
Interface IF_EX_BADI_WCM_WCMOBJ has no event.
Types
Interface IF_EX_BADI_WCM_WCMOBJ has no local type.
Method Signatures
Method CANCEL_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111121 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111121 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20111121 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20111121 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20111121 |
Method CANCEL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method CHANGES_FORBIDDEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_BLST | Value transfer | Type reference (TYPE) | WCTP1_UPDBLSTTAB_TYPE | Einschränkende Status | 20111207 | ||
2 | Importing | IV_ADDITIONAL_DATA | Value transfer | Type reference (TYPE) | WCEIF | Zusatzdaten | 20111207 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111207 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20111207 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20111207 |
Method CHANGES_FORBIDDEN on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method COLOR_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CV_COLOR | Value transfer | Type reference (TYPE) | WCECOLOR | Farbe | 20070822 | ||
2 | Changing | CV_INTENSITY | Value transfer | Type reference (TYPE) | SEU_INTENS | Intensität der Darstellung | 20070823 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070822 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070822 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070822 |
Method COLOR_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method COPY_MODEL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IS_REF_ORDER | Value transfer | Type reference (TYPE) | WCTP1_ORDERWA_TYPE | Struktur: Auftrag | 20070724 | ||
3 | Importing | IS_REF_WCAAP | Value transfer | Type reference (TYPE) | WCTP1_WCAAPWA_TYPE | Struktur: Anforderung | 20070724 | ||
4 | Importing | IS_REF_WCAHE | Value transfer | Type reference (TYPE) | WCTP1_WCAHEWA_TYPE | Struktur: Freischaltliste | 20070724 | ||
5 | Importing | IS_REF_WCAW | Value transfer | Type reference (TYPE) | WCTP1_WCAWWA_TYPE | Struktur: Arbeitsgenehmigung | 20070724 | ||
6 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
7 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
8 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 | ||
9 | Importing | IV_REF_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart (Vorlage) | 20070724 |
Method COPY_MODEL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method FCODE_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20070724 | ||
2 | Importing | IT_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20110523 | ||
3 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
7 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method FUNCTION_AUTHORIZATION_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20120921 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120921 | ||
3 | Importing | IV_FCODE | Value transfer | Type reference (TYPE) | FCODE | Funktionscode | 20120921 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120921 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120921 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120921 | ||
7 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120921 |
Method FUNCTION_AUTHORIZATION_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method FUNCTION_TEXTS_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_DYNTXT_PRI | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Freischaltdokument drucken | 20110823 | ||
2 | Changing | CS_DYNTXT_PRI0 | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Arbeitserlaubnis drucken | 20110823 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110823 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110823 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20110901 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20110823 |
Method FUNCTION_TEXTS_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method GUI_STATUS_FCODE_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20110807 | ||
2 | Importing | IT_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20110807 | ||
3 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20110807 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110807 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110807 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20110807 | ||
7 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20110807 |
Method GUI_STATUS_FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method INIT_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111207 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111207 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20111207 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20111207 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20111207 |
Method INIT_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method JOB_USER_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_CLASS | Value transfer | Type reference (TYPE) | BTCJOBCLAS | Klassifizierung von Jobs | 20120604 | ||
2 | Exporting | EV_GROUP | Value transfer | Type reference (TYPE) | BPSRVGRP | Servergruppe | 20131114 | ||
3 | Exporting | EV_SERVER | Value transfer | Type reference (TYPE) | BTCSRVNAME | Servername | 20131114 | ||
4 | Exporting | EV_USER | Value transfer | Type reference (TYPE) | SYUNAME | Benutzerkennung | 20100727 | ||
5 | Importing | IV_DIRECTION | Value transfer | Type reference (TYPE) | WCEWAY | Richtung | 20100727 | ||
6 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20100727 | ||
7 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20100727 |
Method JOB_USER_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method PLANNING_DATA_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_ACTUAL_DATES | Value transfer | Type reference (TYPE) | WCSACTUAL_DATES | Struktur: Isttermin | 20070724 | ||
2 | Exporting | ES_BASIC_DATES | Value transfer | Type reference (TYPE) | WCSBASIC_DATES | Struktur: Ecktermin | 20070724 | ||
3 | Exporting | ES_SCHEDULED_DATES | Value transfer | Type reference (TYPE) | WCSSCHEDULED_DATES | Struktur: Terminiert | 20070724 | ||
4 | Importing | IS_ACTUAL_DATES | Value transfer | Type reference (TYPE) | WCSACTUAL_DATES | Struktur: Isttermin | 20070724 | ||
5 | Importing | IS_BASIC_DATES | Value transfer | Type reference (TYPE) | WCSBASIC_DATES | Struktur: Ecktermin | 20070724 | ||
6 | Importing | IS_SCHEDULED_DATES | Value transfer | Type reference (TYPE) | WCSSCHEDULED_DATES | Struktur: Terminiert | 20070724 | ||
7 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
8 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
9 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
10 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
11 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method PLANNING_DATA_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method PRINT_CONTROL_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_PRTCTRL | Value transfer | Type reference (TYPE) | WCSPRINT | Einstellungen zum Druck | 20110823 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110823 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110823 |
Method PRINT_CONTROL_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method PRINT_HEADER_DATA_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method PRINT_HEADER_DATA_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method PRINT_WORK_PERMIT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_COPYFLG | Value transfer | Type reference (TYPE) | WCECOPYFLG | Kennzeichen: Kopie | 20070724 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
7 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method PRINT_WORK_PERMIT_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method SAVE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070801 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070801 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070801 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070801 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070801 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070801 |
Method SAVE_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method SAVE_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111121 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111121 | ||
3 | Importing | IV_NEWOBJ | Value transfer | Type reference (TYPE) | J_OBJNR | Neue Objektnummer | 20111121 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20111121 | ||
5 | Importing | IV_OBJKEY | Value transfer | Type reference (TYPE) | WCENO | Schlüssel | 20111121 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20111121 | ||
7 | Importing | IV_OLDOBJ | Value transfer | Type reference (TYPE) | J_OBJNR | Alte Objektnummer | 20111121 |
Method SAVE_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_CHGN_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_CHGN_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_CHGN_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_CHGN_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_CLSD_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_INFO | Value transfer | Type reference (TYPE) | WCEINFO | Booelscher Wert: Meldung kann ausgeben werden | 20070724 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
7 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_CLSD_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_CLSD_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_CLSD_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_DLFL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_DLFL_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_DLFL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_INAC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_INAC_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_INAC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_PREP_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_PREP_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_PREP_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_PREP_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_REJC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_REJC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_REJC_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_REJC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_RESET_DLFL_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_RESET_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_RESET_DLFL_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_RESET_DLFL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_RESET_INAC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method STATUS_RESET_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method STATUS_RESET_INAC_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120116 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120116 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20120116 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120116 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120116 |
Method STATUS_RESET_INAC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method TEMPLATE_DISPLAY_REDUCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_DELETE | Value transfer | Type reference (TYPE) | WCTPC_INDEXTAB_TYPE | Index der zu unterdrückenden Vorlagenzuordnungen | 20111027 | ||
2 | Importing | IT_SELECTION | Value transfer | Type reference (TYPE) | WCTIO7 | Tabelle der anzuzeigenden Vorlagenzuordnungen | 20111027 | ||
3 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111027 | ||
4 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111026 | ||
5 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20111026 | ||
6 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Objektnummer | 20111026 | ||
7 | Importing | IV_REFART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart der zugeordneten Vorlagen | 20111026 |
Method TEMPLATE_DISPLAY_REDUCE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method TEMPLATE_FCODE_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_EXCL | Value transfer | Type reference (TYPE) | WCTPF_EXCLTAB_TYPE | Tabelle der zu (deaktivierenden) Funktionscodes | 20110907 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20110907 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110907 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110907 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20110907 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20110907 |
Method TEMPLATE_FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method TEMPLATE_SEARCH_REPLACE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ET_WCAAP | Call by reference | Type reference (TYPE) | WCTP1_WCAAPTAB_TYPE | Tabelle der Ausgewählten Anforderungen | 20110805 | ||
2 | Exporting | ET_WCAHE | Call by reference | Type reference (TYPE) | WCTP1_WCAHETAB_TYPE | Tabelle der Ausgewählten Freischaltlisten | 20110805 | ||
3 | Exporting | EV_NO_ENTRIES | Call by reference | Type reference (TYPE) | WCEBOOLEAN | 1 := Keine Einträge sind zulässig | 20110805 | ||
4 | Importing | IT_R_OBJNR | Value transfer | Type reference (TYPE) | WCT_OBJNR | Objektnummer (Einschränkungen) | 20110805 | ||
5 | Importing | IV_CCOBJ | Value transfer | Type reference (TYPE) | WCECCOBJ | Technisches Objekt | 20110805 | ||
6 | Importing | IV_CCTYP | Value transfer | Type reference (TYPE) | WCECCTYP | Typ des technischen Objekt | 20110805 | ||
7 | Importing | IV_DIRECTION | Value transfer | Type reference (TYPE) | WCEWAY | Leserichtung für das technische Objekt | 20110901 | ||
8 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110805 | ||
9 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110805 | ||
10 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Freischaltdokuments | 20110805 | ||
11 | Importing | IV_SELECTION_SCREEN | Value transfer | Type reference (TYPE) | WCEBOOLEAN | 1 := Selektionsbild ist erlaubt | 20110901 |
Method TEMPLATE_SEARCH_REPLACE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method TEXT_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CV_PTXT | Value transfer | Type reference (TYPE) | WCEPTXT | Beschreibender Kurztext im Plural | 20070822 | ||
2 | Changing | CV_STXT | Value transfer | Type reference (TYPE) | WCESTXT | Beschreibender Kurztext im Singular | 20070822 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070822 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070822 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070822 |
Method TEXT_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method UPDFLG_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_UPDFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Änderungskennzeichen | 20070924 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070924 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070924 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070924 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070924 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070924 |
Method UPDFLG_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method USAGE_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CV_USAGE | Value transfer | Type reference (TYPE) | WCEUSAGE | Verwendung des Freischaltdokuments | 20110803 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110803 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110803 | ||
4 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20110803 | ||
5 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20110803 |
Method USAGE_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method USRFLD_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_USRFLD | Value transfer | Type reference (TYPE) | WCTP1_USRFLD_TYPE | Benutzerfeld | 20070724 | ||
2 | Importing | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
4 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20070724 | ||
5 | Importing | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | ||
6 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 |
Method USRFLD_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
Method VIEWPROFILE_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CV_PROFILE | Value transfer | Type reference (TYPE) | WCEVIEWPROFILE | Sichtenprofil | 20110528 | ||
2 | Importing | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20110528 | ||
3 | Importing | IV_OBJART | Value transfer | Type reference (TYPE) | WCEOBJART | Objektart | 20110528 | ||
4 | Importing | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20110528 |
Method VIEWPROFILE_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in | 603 |