SAP ABAP Interface IF_EX_BADI_WCM_WCMOBJ (Interface for BAdI: BADI_WCM_WCMOBJ)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   PM-WCM (Application Component) Work Clearance Management
     WCM (Package) WCM: Work Clearance Management
Properties
Interface IF_EX_BADI_WCM_WCMOBJ  
Short Description Interface for BAdI: BADI_WCM_WCMOBJ    
General Data
Package WCM   WCM: Work Clearance Management 
Created 20070724   SAP 
Last changed 20140121   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 WCTP1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 WCTP3 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 WCTPC Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 WCTPD Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
5 WCTPF Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
6 WCTPP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
# Interface Abstract Final Description Created on
1 IF_BADI_INTERFACE Tag Interface for BAdIs 20070724
Friends
Interface IF_EX_BADI_WCM_WCMOBJ has no friend.
Attributes
Interface IF_EX_BADI_WCM_WCMOBJ has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CANCEL_FINALIZE Instance method Public Method Final Tasks While Terminating 20111121
2 CHANGES_FORBIDDEN Instance method Public Method Changes to Additional Data Forbidden 20111207
3 COLOR_MODIFY Instance method Public Method Change Color 20070822
4 COPY_MODEL_CHECK Instance method Public Method Check Creation with Template 20070724
5 FCODE_DEACTIVATE Instance method Public Method Deactivate Function Codes 20070724
6 FUNCTION_AUTHORIZATION_CHECK Instance method Public Method Check Authorization for a Function 20120921
7 FUNCTION_TEXTS_MODIFY Instance method Public Method Set Pushbutton Text for Printing 20110823
8 GUI_STATUS_FCODE_DEACTIVATE Instance method Public Method Deactivate Functions of Set GUI Status 20110807
9 INIT_FINALIZE Instance method Public Method Final Work During Initialization 20111207
10 JOB_USER_GET Instance method Public Method Set User ID 20100727
11 PLANNING_DATA_GET Instance method Public Method Set Planning Data 20070724
12 PRINT_CONTROL_MODIFY Instance method Public Method Change Print Settings 20110823
13 PRINT_HEADER_DATA_CHECK Instance method Public Method Check Printing of Header Data 20070724
14 PRINT_WORK_PERMIT_CHECK Instance method Public Method Check Printing of Work Permit 20070724
15 SAVE_CHECK Instance method Public Method Check Save 20070801
16 SAVE_FINALIZE Instance method Public Method Final Tasks While Saving 20111121
17 STATUS_CHGN_CHECK Instance method Public Method Check Setting of Status "Change Mode" 20070724
18 STATUS_CHGN_FINALIZE Instance method Public Method Work After Setting of Status "Change Mode" 20120116
19 STATUS_CLSD_CHECK Instance method Public Method Check Setting of Status "Closed" 20070724
20 STATUS_CLSD_FINALIZE Instance method Public Method Work After Setting of Status "Closed" 20120116
21 STATUS_DLFL_CHECK Instance method Public Method Check Setting of Status "Deletion Flag Set" 20070724
22 STATUS_DLFL_FINALIZE Instance method Public Method Work After Setting of Status "Deletion Flag Set" 20120116
23 STATUS_INAC_CHECK Instance method Public Method Check Setting of Status "Inactive" 20070724
24 STATUS_INAC_FINALIZE Instance method Public Method Work After Setting of Status "Inactive" 20120116
25 STATUS_PREP_CHECK Instance method Public Method Check Setting of Status "Prepared" 20070724
26 STATUS_PREP_FINALIZE Instance method Public Method Work After Setting of Status "Prepared" 20120116
27 STATUS_REJC_CHECK Instance method Public Method Check Setting of Status "Rejected" 20070724
28 STATUS_REJC_FINALIZE Instance method Public Method Work After Setting of Status "Rejected" 20120116
29 STATUS_RESET_DLFL_CHECK Instance method Public Method Check Revoking of Status "Deletion Flag Set" 20070724
30 STATUS_RESET_DLFL_FINALIZE Instance method Public Method Work After Resetting of Status "Deletion Flag Set" 20120116
31 STATUS_RESET_INAC_CHECK Instance method Public Method Check Revoking of Status "Inactive" 20070724
32 STATUS_RESET_INAC_FINALIZE Instance method Public Method Work After Resetting of Status "Inactive" 20120116
33 TEMPLATE_DISPLAY_REDUCE Instance method Public Method Restricted Template Assignments Displayed 20111026
34 TEMPLATE_FCODE_DEACTIVATE Instance method Public Method Deactivate Function Codes (Templates) 20110907
35 TEMPLATE_SEARCH_REPLACE Instance method Public Method Replaces the Selection of Templates for Assignment 20110805
36 TEXT_MODIFY Instance method Public Method Change Short Text 20070822
37 UPDFLG_GET Instance method Public Method Set Change Indicator 20070924
38 USAGE_MODIFY Instance method Public Method Change Usage 20110803
39 USRFLD_GET Instance method Public Method Set User Field 20070724
40 VIEWPROFILE_MODIFY Instance method Public Method Change View Profile 20110528
Events
Interface IF_EX_BADI_WCM_WCMOBJ has no event.
Types
Interface IF_EX_BADI_WCM_WCMOBJ has no local type.
Method Signatures

Method CANCEL_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20111121
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111121
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20111121
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20111121
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20111121

Method CANCEL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method CHANGES_FORBIDDEN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_BLST Value transfer Type reference (TYPE) WCTP1_UPDBLSTTAB_TYPE Einschränkende Status 20111207
2 Importing IV_ADDITIONAL_DATA Value transfer Type reference (TYPE) WCEIF Zusatzdaten 20111207
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111207
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20111207
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20111207

Method CHANGES_FORBIDDEN on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method COLOR_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_COLOR Value transfer Type reference (TYPE) WCECOLOR Farbe 20070822
2 Changing CV_INTENSITY Value transfer Type reference (TYPE) SEU_INTENS Intensität der Darstellung 20070823
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070822
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070822
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070822

Method COLOR_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method COPY_MODEL_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IS_REF_ORDER Value transfer Type reference (TYPE) WCTP1_ORDERWA_TYPE Struktur: Auftrag 20070724
3 Importing IS_REF_WCAAP Value transfer Type reference (TYPE) WCTP1_WCAAPWA_TYPE Struktur: Anforderung 20070724
4 Importing IS_REF_WCAHE Value transfer Type reference (TYPE) WCTP1_WCAHEWA_TYPE Struktur: Freischaltliste 20070724
5 Importing IS_REF_WCAW Value transfer Type reference (TYPE) WCTP1_WCAWWA_TYPE Struktur: Arbeitsgenehmigung 20070724
6 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
7 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
8 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724
9 Importing IV_REF_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart (Vorlage) 20070724

Method COPY_MODEL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method FCODE_DEACTIVATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_EXCL Value transfer Type reference (TYPE) WCTPF_EXCLTAB_TYPE Tabelle der zu (deaktivierenden) Funktionscodes 20070724
2 Importing IT_EXCL Value transfer Type reference (TYPE) WCTPF_EXCLTAB_TYPE Tabelle der zu (deaktivierenden) Funktionscodes 20110523
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
6 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
7 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method FUNCTION_AUTHORIZATION_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20120921
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120921
3 Importing IV_FCODE Value transfer Type reference (TYPE) FCODE Funktionscode 20120921
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120921
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120921
6 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120921
7 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120921

Method FUNCTION_AUTHORIZATION_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method FUNCTION_TEXTS_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_DYNTXT_PRI Value transfer Type reference (TYPE) SMP_DYNTXT Funktions- oder Menütext: Freischaltdokument drucken 20110823
2 Changing CS_DYNTXT_PRI0 Value transfer Type reference (TYPE) SMP_DYNTXT Funktions- oder Menütext: Arbeitserlaubnis drucken 20110823
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110823
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110823
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20110901
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20110823

Method FUNCTION_TEXTS_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method GUI_STATUS_FCODE_DEACTIVATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_EXCL Value transfer Type reference (TYPE) WCTPF_EXCLTAB_TYPE Tabelle der zu (deaktivierenden) Funktionscodes 20110807
2 Importing IT_EXCL Value transfer Type reference (TYPE) WCTPF_EXCLTAB_TYPE Tabelle der zu (deaktivierenden) Funktionscodes 20110807
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20110807
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110807
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110807
6 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20110807
7 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20110807

Method GUI_STATUS_FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method INIT_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20111207
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111207
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20111207
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20111207
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20111207

Method INIT_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method JOB_USER_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_CLASS Value transfer Type reference (TYPE) BTCJOBCLAS Klassifizierung von Jobs 20120604
2 Exporting EV_GROUP Value transfer Type reference (TYPE) BPSRVGRP Servergruppe 20131114
3 Exporting EV_SERVER Value transfer Type reference (TYPE) BTCSRVNAME Servername 20131114
4 Exporting EV_USER Value transfer Type reference (TYPE) SYUNAME Benutzerkennung 20100727
5 Importing IV_DIRECTION Value transfer Type reference (TYPE) WCEWAY Richtung 20100727
6 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20100727
7 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20100727

Method JOB_USER_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method PLANNING_DATA_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_ACTUAL_DATES Value transfer Type reference (TYPE) WCSACTUAL_DATES Struktur: Isttermin 20070724
2 Exporting ES_BASIC_DATES Value transfer Type reference (TYPE) WCSBASIC_DATES Struktur: Ecktermin 20070724
3 Exporting ES_SCHEDULED_DATES Value transfer Type reference (TYPE) WCSSCHEDULED_DATES Struktur: Terminiert 20070724
4 Importing IS_ACTUAL_DATES Value transfer Type reference (TYPE) WCSACTUAL_DATES Struktur: Isttermin 20070724
5 Importing IS_BASIC_DATES Value transfer Type reference (TYPE) WCSBASIC_DATES Struktur: Ecktermin 20070724
6 Importing IS_SCHEDULED_DATES Value transfer Type reference (TYPE) WCSSCHEDULED_DATES Struktur: Terminiert 20070724
7 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
8 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
9 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
10 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
11 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method PLANNING_DATA_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method PRINT_CONTROL_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_PRTCTRL Value transfer Type reference (TYPE) WCSPRINT Einstellungen zum Druck 20110823
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110823
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110823

Method PRINT_CONTROL_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method PRINT_HEADER_DATA_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method PRINT_HEADER_DATA_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method PRINT_WORK_PERMIT_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_COPYFLG Value transfer Type reference (TYPE) WCECOPYFLG Kennzeichen: Kopie 20070724
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
6 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
7 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method PRINT_WORK_PERMIT_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method SAVE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070801
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070801
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070801
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070801
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070801
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070801

Method SAVE_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method SAVE_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20111121
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111121
3 Importing IV_NEWOBJ Value transfer Type reference (TYPE) J_OBJNR Neue Objektnummer 20111121
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20111121
5 Importing IV_OBJKEY Value transfer Type reference (TYPE) WCENO Schlüssel 20111121
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20111121
7 Importing IV_OLDOBJ Value transfer Type reference (TYPE) J_OBJNR Alte Objektnummer 20111121

Method SAVE_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_CHGN_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_CHGN_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_CHGN_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_CHGN_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_CLSD_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_INFO Value transfer Type reference (TYPE) WCEINFO Booelscher Wert: Meldung kann ausgeben werden 20070724
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
6 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
7 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_CLSD_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_CLSD_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_CLSD_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_DLFL_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_DLFL_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_DLFL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_INAC_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_INAC_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_INAC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_PREP_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_PREP_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_PREP_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_PREP_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_REJC_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_REJC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_REJC_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_REJC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_RESET_DLFL_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_RESET_DLFL_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_RESET_DLFL_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_RESET_DLFL_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_RESET_INAC_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RETURN_VALUE Value transfer Type reference (TYPE) SYSUBRC Rückgabewert 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method STATUS_RESET_INAC_CHECK on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method STATUS_RESET_INAC_FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20120116
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20120116
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20120116
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20120116
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20120116

Method STATUS_RESET_INAC_FINALIZE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method TEMPLATE_DISPLAY_REDUCE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_DELETE Value transfer Type reference (TYPE) WCTPC_INDEXTAB_TYPE Index der zu unterdrückenden Vorlagenzuordnungen 20111027
2 Importing IT_SELECTION Value transfer Type reference (TYPE) WCTIO7 Tabelle der anzuzeigenden Vorlagenzuordnungen 20111027
3 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20111027
4 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20111026
5 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20111026
6 Importing IV_OBJNR Value transfer Type reference (TYPE) WCTP1_OBJNR_TYPE Objektnummer 20111026
7 Importing IV_REFART Value transfer Type reference (TYPE) WCEOBJART Objektart der zugeordneten Vorlagen 20111026

Method TEMPLATE_DISPLAY_REDUCE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method TEMPLATE_FCODE_DEACTIVATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_EXCL Value transfer Type reference (TYPE) WCTPF_EXCLTAB_TYPE Tabelle der zu (deaktivierenden) Funktionscodes 20110907
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20110907
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110907
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110907
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20110907
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20110907

Method TEMPLATE_FCODE_DEACTIVATE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method TEMPLATE_SEARCH_REPLACE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_WCAAP Call by reference Type reference (TYPE) WCTP1_WCAAPTAB_TYPE Tabelle der Ausgewählten Anforderungen 20110805
2 Exporting ET_WCAHE Call by reference Type reference (TYPE) WCTP1_WCAHETAB_TYPE Tabelle der Ausgewählten Freischaltlisten 20110805
3 Exporting EV_NO_ENTRIES Call by reference Type reference (TYPE) WCEBOOLEAN 1 := Keine Einträge sind zulässig 20110805
4 Importing IT_R_OBJNR Value transfer Type reference (TYPE) WCT_OBJNR Objektnummer (Einschränkungen) 20110805
5 Importing IV_CCOBJ Value transfer Type reference (TYPE) WCECCOBJ Technisches Objekt 20110805
6 Importing IV_CCTYP Value transfer Type reference (TYPE) WCECCTYP Typ des technischen Objekt 20110805
7 Importing IV_DIRECTION Value transfer Type reference (TYPE) WCEWAY Leserichtung für das technische Objekt 20110901
8 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110805
9 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110805
10 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Typ des Freischaltdokuments 20110805
11 Importing IV_SELECTION_SCREEN Value transfer Type reference (TYPE) WCEBOOLEAN 1 := Selektionsbild ist erlaubt 20110901

Method TEMPLATE_SEARCH_REPLACE on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method TEXT_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_PTXT Value transfer Type reference (TYPE) WCEPTXT Beschreibender Kurztext im Plural 20070822
2 Changing CV_STXT Value transfer Type reference (TYPE) WCESTXT Beschreibender Kurztext im Singular 20070822
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070822
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070822
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070822

Method TEXT_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method UPDFLG_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_UPDFLG Value transfer Type reference (TYPE) WCTP1_FLG_TYPE Änderungskennzeichen 20070924
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070924
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070924
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070924
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070924
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070924

Method UPDFLG_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method USAGE_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_USAGE Value transfer Type reference (TYPE) WCEUSAGE Verwendung des Freischaltdokuments 20110803
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110803
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110803
4 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20110803
5 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20110803

Method USAGE_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method USRFLD_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_USRFLD Value transfer Type reference (TYPE) WCTP1_USRFLD_TYPE Benutzerfeld 20070724
2 Importing IV_AKTYP Value transfer Type reference (TYPE) AKTYP Aktivitätstyp 20070724
3 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20070724
4 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20070724
5 Importing IV_OBJNR Value transfer Type reference (TYPE) J_OBJNR Objektnummer 20070724
6 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20070724

Method USRFLD_GET on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.

Method VIEWPROFILE_MODIFY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_PROFILE Value transfer Type reference (TYPE) WCEVIEWPROFILE Sichtenprofil 20110528
2 Importing IV_IWERK Value transfer Type reference (TYPE) IWERK Planungswerk 20110528
3 Importing IV_OBJART Value transfer Type reference (TYPE) WCEOBJART Objektart 20110528
4 Importing IV_OBJTYP Value transfer Type reference (TYPE) WCETYP Subobjektart 20110528

Method VIEWPROFILE_MODIFY on Interface IF_EX_BADI_WCM_WCMOBJ has no exception.
History
Last changed by/on SAP  20140121 
SAP Release Created in 603