SAP ABAP Interface IF_EX_BADI_WCM_WAPI_003 (Interface for BAdI: BADI_WCM_WCA_003)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
PM-WCM (Application Component) Work Clearance Management
⤷
WCM (Package) WCM: Work Clearance Management

⤷

⤷

Properties
Interface | IF_EX_BADI_WCM_WAPI_003 | |
Short Description | Interface for BAdI: BADI_WCM_WCA_003 |
General Data
Package | WCM | WCM: Work Clearance Management |
Created | 20091230 | SAP |
Last changed | 20131127 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | WCTP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | WCTP3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | WCTPC | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | WCTPP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20091230 |
Friends
Interface IF_EX_BADI_WCM_WAPI_003 has no friend.
Attributes
Interface IF_EX_BADI_WCM_WAPI_003 has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Check Whether Extension of Validity Can Be Allowed | 20091230 |
2 | ![]() |
Instance method | Public | Method | Set Text for Life-Cycle Phase | 20100922 |
3 | ![]() |
Instance method | Public | Method | Check Whether Work Permit Can Be Returned | 20121126 |
4 | ![]() |
Instance method | Public | Method | Check Whether Work Permit Can Be Handed Out | 20121126 |
5 | ![]() |
Instance method | Public | Method | Deactivate Work and Requirements Individually | 20130423 |
6 | ![]() |
Instance method | Public | Method | Set Work And Requirements | 20100209 |
Events
Interface IF_EX_BADI_WCM_WAPI_003 has no event.
Types
Interface IF_EX_BADI_WCM_WAPI_003 has no local type.
Method Signatures
Method EXTEND_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20091230 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20091230 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20091230 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20091230 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Anforderung | 20100209 |
Method EXTEND_CHECK on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
Method PHASE_TEXT_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_DYNTXT | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext | 20100922 | ||
2 | ![]() |
IS_STATFLG | Value transfer | Type reference (TYPE) | WCSSTATFLG | Kennzeichen für Status (Kopf) | 20110708 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20100922 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20100922 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Anforderung | 20100922 | ||
6 | ![]() |
IV_PHASE | Value transfer | Type reference (TYPE) | WCELCPHASE | Lebensphase | 20100922 | ||
7 | ![]() |
IV_TLCNT | Value transfer | Type reference (TYPE) | WCTP1_TLCNT_TYPE | Genehmigungsstatus | 20110708 | ||
8 | ![]() |
IV_VALID | Value transfer | Type reference (TYPE) | WCEVALID | Gültigkeit | 20110708 |
Method PHASE_TEXT_MODIFY on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
Method STATUS_RESET_WPHO_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20121126 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20121126 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20121126 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20121126 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Anforderung | 20121126 |
Method STATUS_RESET_WPHO_CHECK on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
Method STATUS_WPHO_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20121126 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20121126 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20121126 | ||
4 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20121126 | ||
5 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Anforderung | 20121126 |
Method STATUS_WPHO_CHECK on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
Method WORK_NEED_DEACTIVATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_DEACTIVATE | Value transfer | Type reference (TYPE) | WCTP1_BOOLEAN_TYPE | Booelscher Wert: Deaktivierung Eingabefeld erforderlich | 20130423 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20130423 | ||
3 | ![]() |
IV_FIELDNAME | Value transfer | Type reference (TYPE) | WCTP1_FIELD_TYPE | Name des Eingabefeldes (Arbeit/Erfordernis) | 20130423 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20130423 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20130423 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ der Anforderung | 20130423 |
Method WORK_NEED_DEACTIVATE on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
Method WORK_NEED_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_NEEDID | Call by reference | Type reference (TYPE) | WCSNEEDID | Erfordernisse | 20100209 | ||
2 | ![]() |
CS_WKID | Call by reference | Type reference (TYPE) | WCSWKID | Arbeiten | 20100209 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20100209 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20100209 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20100209 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Typ des Anforderung | 20100209 |
Method WORK_NEED_MODIFY on Interface IF_EX_BADI_WCM_WAPI_003 has no exception.
History
Last changed by/on | SAP | 20131127 |
SAP Release Created in | 605 |