SAP ABAP Interface IF_EX_BADI_WCM_WAPI_001 (Interface for BAdI: BADI_WCM_WAPI_001)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
PM-WCM (Application Component) Work Clearance Management
⤷
WCM (Package) WCM: Work Clearance Management
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_WCM_WAPI_001 | WCM: Requirements (Screen Enhancements) | 20070614 |
Properties
| Interface | IF_EX_BADI_WCM_WAPI_001 | |
| Short Description | Interface for BAdI: BADI_WCM_WAPI_001 |
General Data
| Package | WCM | WCM: Work Clearance Management |
| Created | 20070614 | SAP |
| Last changed | 20130531 | SAP |
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | WCTP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 2 | WCTP2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 3 | WCTP3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 4 | WCTPC | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 5 | WCTPF | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
| 6 | WCTPP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20070614 |
Friends
Interface IF_EX_BADI_WCM_WAPI_001 has no friend.
Attributes
Interface IF_EX_BADI_WCM_WAPI_001 has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Transport Data from Subscreen | 20070614 | |
| 2 | Instance method | Public | Method | Transport Data to Subscreen | 20070614 | |
| 3 | Instance method | Public | Method | Execute Function Code | 20111018 | |
| 4 | Instance method | Public | Method | Set Tab Page Title | 20070627 |
Events
Interface IF_EX_BADI_WCM_WAPI_001 has no event.
Types
Interface IF_EX_BADI_WCM_WAPI_001 has no local type.
Method Signatures
Method SUBSCREEN_DATA_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ES_WAPI | Value transfer | Type reference (TYPE) | WCSWAPI | Struktur: Anforderung | 20070724 | |||
| 2 | IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20111017 |
Method SUBSCREEN_DATA_GET on Interface IF_EX_BADI_WCM_WAPI_001 has no exception.
Method SUBSCREEN_DATA_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_WAPI | Value transfer | Type reference (TYPE) | WCSWAPI | Struktur: Anforderung | 20070724 | |||
| 2 | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | |||
| 3 | IV_DYNFLDGRP | Value transfer | Type reference (TYPE) | WCEDYNFLDGRP | Gruppierung von Subscreen-Feldern | 20111012 | |||
| 4 | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | |||
| 5 | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070724 | |||
| 6 | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20070724 | |||
| 7 | IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20111017 |
Method SUBSCREEN_DATA_SET on Interface IF_EX_BADI_WCM_WAPI_001 has no exception.
Method SUBSCREEN_FCODE_EXECUTE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_PROCESSED | Value transfer | Type reference (TYPE) | WCEBOOLEAN | 1 := Verarbeitung ist erfolgt | 20111018 | |||
| 2 | IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111018 | |||
| 3 | IV_FCODE | Value transfer | Type reference (TYPE) | WCTPF_FCODE_TYPE | Funktionscode | 20111018 | |||
| 4 | IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111018 | |||
| 5 | IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20111018 | |||
| 6 | IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20111018 | |||
| 7 | IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20111018 |
Method SUBSCREEN_FCODE_EXECUTE on Interface IF_EX_BADI_WCM_WAPI_001 has no exception.
Method TAB_PAGE_TITLE_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_TITLE | Value transfer | Type reference (TYPE) | WCTP2_TAB_PAGE_TITLE_TYPE | Registerkarte | 20070724 |
Method TAB_PAGE_TITLE_GET on Interface IF_EX_BADI_WCM_WAPI_001 has no exception.
History
| Last changed by/on | SAP | 20130531 |
| SAP Release Created in | 700 |