Hierarchy

⤷

⤷

Properties
Interface | IF_EX_BADI_WCM_OPWC | |
Short Description | Interface for BAdI: BADI_WCM_OPWC |
General Data
Package | WCM | WCM: Work Clearance Management |
Created | 20070723 | SAP |
Last changed | 20140121 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | WCTP1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | WCTP3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | WCTPC | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | WCTPD | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
5 | WCTPP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20070723 |
Friends
Interface IF_EX_BADI_WCM_OPWC has no friend.
Attributes
Interface IF_EX_BADI_WCM_OPWC has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Restrict Items in Template To Be Copied | 20100201 |
2 | ![]() |
Instance method | Public | Method | Set Texts for Pushbuttons for Operational Cycle | 20070825 |
3 | ![]() |
Instance method | Public | Method | Revise Data | 20070801 |
4 | ![]() |
Instance method | Public | Method | General Entry Check | 20111104 |
5 | ![]() |
Instance method | Public | Method | Check Setting of Status "Tag" | 20070724 |
6 | ![]() |
Instance method | Public | Method | Check Setting of Status "Untag Temporarily" | 20070724 |
7 | ![]() |
Instance method | Public | Method | Check Setting of Status "Untag" | 20070724 |
8 | ![]() |
Instance method | Public | Method | Check Setting of Status "Tagged" | 20070724 |
9 | ![]() |
Instance method | Public | Method | Check Setting of Status "Temporarily Untagged" | 20070724 |
10 | ![]() |
Instance method | Public | Method | Check Setting of Status "Untagged" | 20070724 |
11 | ![]() |
Instance method | Public | Method | Check Whether Item Can Be Deactivated | 20070730 |
12 | ![]() |
Instance method | Public | Method | Check Whether Operational Protection Can Be Set | 20070723 |
13 | ![]() |
Instance method | Public | Method | Check Setting of Status "Tag Printed" | 20070724 |
14 | ![]() |
Instance method | Public | Method | Check Setting of Status "Test Tag Printed" | 20070724 |
15 | ![]() |
Instance method | Public | Method | Check Whether Operational Protection Can Be Revoked | 20070723 |
16 | ![]() |
Instance method | Public | Method | Finalizing Work After Switching Items | 20131129 |
17 | ![]() |
Instance method | Public | Method | Simulation on Maintenance Screen | 20070730 |
18 | ![]() |
Instance method | Public | Method | Sort Items on Maintenance Screen | 20070730 |
19 | ![]() |
Instance method | Public | Method | Restrict Insertion from the Clipboard | 20120301 |
20 | ![]() |
Instance method | Public | Method | Input Check for Lock (Physical Blocking) | 20070822 |
21 | ![]() |
Instance method | Public | Method | Input Help for Lock (Physical Blocking) | 20070822 |
22 | ![]() |
Instance method | Public | Method | Check Setting of Status "Prepared" | 20070730 |
23 | ![]() |
Instance method | Public | Method | Check Printing of Operational List for Tagging | 20070723 |
24 | ![]() |
Instance method | Public | Method | Check Printing of Tags | 20070723 |
25 | ![]() |
Instance method | Public | Method | Check Multiple Use of a Tag | 20101021 |
26 | ![]() |
Instance method | Public | Method | Check Printing of Test Tags | 20070723 |
27 | ![]() |
Instance method | Public | Method | Check Multiple Use of a Test Tag | 20101021 |
28 | ![]() |
Instance method | Public | Method | Check Printing of Operational List for Untagging | 20070723 |
29 | ![]() |
Instance method | Public | Method | Change Logical Destination | 20070730 |
30 | ![]() |
Instance method | Public | Method | Revise Selection | 20070730 |
31 | ![]() |
Instance method | Public | Method | Simulation on Switching Screen | 20070723 |
32 | ![]() |
Instance method | Public | Method | Sort Items on Switching Screen | 20070723 |
33 | ![]() |
Instance method | Public | Method | Check Operational List for Tagging for Mobile Processing | 20070723 |
34 | ![]() |
Instance method | Public | Method | Check Setting of Status "Untaggable" | 20070723 |
35 | ![]() |
Instance method | Public | Method | Check Operational List for Untagging for Mobile Processing | 20070723 |
36 | ![]() |
Instance method | Public | Method | Set User Field | 20070730 |
Events
Interface IF_EX_BADI_WCM_OPWC has no event.
Types
Interface IF_EX_BADI_WCM_OPWC has no local type.
Method Signatures
Method COPY_MODEL_REDUCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_WCAIT | Value transfer | Type reference (TYPE) | WCTP1_WCAITTAB_TYPE | Einschränkungen | 20100201 | ||
2 | ![]() |
IT_WCAIT | Value transfer | Type reference (TYPE) | WCTP1_WCAITTAB_TYPE | Auswahlmenge | 20100201 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20100201 | ||
4 | ![]() |
IV_REFWC | Value transfer | Type reference (TYPE) | WCEREFWC | Freischaltliste (Vorlage) | 20100201 |
Method COPY_MODEL_REDUCE on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method FUNCTION_TEXTS_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CS_DYNTXT_BTG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Freischalten | 20070825 | ||
2 | ![]() |
CS_DYNTXT_BTUG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Temporär normalisieren | 20070825 | ||
3 | ![]() |
CS_DYNTXT_BUG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Normalisieren | 20070825 | ||
4 | ![]() |
CS_DYNTXT_ETG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Freigeschaltet | 20070825 | ||
5 | ![]() |
CS_DYNTXT_ETUG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Temporär normalisiert | 20070825 | ||
6 | ![]() |
CS_DYNTXT_EUG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Normalisiert | 20070825 | ||
7 | ![]() |
CS_DYNTXT_PTAG | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Freischaltzettel drucken | 20070825 | ||
8 | ![]() |
CS_DYNTXT_PTST | Value transfer | Type reference (TYPE) | SMP_DYNTXT | Funktions- oder Menütext: Testzettel drucken | 20070825 | ||
9 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070825 | ||
10 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070825 | ||
11 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20070825 | ||
12 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20070909 |
Method FUNCTION_TEXTS_MODIFY on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method GRAPHICAL_SYSTEM_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CT_ITM | Value transfer | Type reference (TYPE) | RFC_WCDITM_DATATAB | Daten der übergebenen Positionen | 20070801 | ||
2 | ![]() |
IT_HDR | Value transfer | Type reference (TYPE) | RFC_WCD_DATA | Kopfdaten der Freischaltliste | 20071010 | ||
3 | ![]() |
IT_HDR_STATUS | Value transfer | Type reference (TYPE) | RFC_WCD_STATUS | Status der Freischaltliste | 20071010 | ||
4 | ![]() |
IT_ITM_INSCTRL | Value transfer | Type reference (TYPE) | RFC_WCDITM_CTRL | Pflegekennzeichen für neue Positionen | 20071010 | ||
5 | ![]() |
IT_ITM_STATUS | Value transfer | Type reference (TYPE) | RFC_WCDITM_STATUSTAB | Status der Positionen | 20071010 | ||
6 | ![]() |
IT_ITM_UPDCTRL | Value transfer | Type reference (TYPE) | RFC_WCDITM_UPDCTRLTAB | Pflegekennzeichen für übergebene Positionen | 20071010 | ||
7 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070801 | ||
8 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070801 | ||
9 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070801 | ||
10 | ![]() |
IV_POINT_OF_TIME | Value transfer | Type reference (TYPE) | WCETIMEPOINT | Zeitpunkt | 20070815 |
Method GRAPHICAL_SYSTEM_MODIFY on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_DATA_INPUT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20111104 | ||
2 | ![]() |
IS_ITM | Value transfer | Type reference (TYPE) | WCSWCITM | Struktur: Positionen | 20111104 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20111104 | ||
4 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20111104 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20111104 |
Method ITEM_DATA_INPUT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_BTG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_BTG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_BTUG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_BTUG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_BUG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_BUG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_ETG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_ETG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_ETUG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_ETUG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_EUG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_EUG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_INAC_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070730 | ||
2 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
3 | ![]() |
IV_ITM_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Position) | 20070730 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method ITEM_STATUS_INAC_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_PROT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_PROT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_PTAG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_PTAG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_PTST_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_PTST_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_STATUS_RESET_PROT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070728 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method ITEM_STATUS_RESET_PROT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method ITEM_SWITCHING_FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IT_VRGNG_ALL | Value transfer | Type reference (TYPE) | WCTP3_VRGNGTAB_TYPE | Ursprünglich auszuführende betriebswirtschaftliche Vorgänge | 20131129 | ||
2 | ![]() |
IT_VRGNG_UPD | Value transfer | Type reference (TYPE) | WCTP3_VRGNGTAB_TYPE | Tatsächlich ausgeführte betriebswirtschaftliche Vorgänge | 20131129 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20131129 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20131129 |
Method ITEM_SWITCHING_FINALIZE on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method MAINTENANCE_SCREEN_SIMULATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
2 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method MAINTENANCE_SCREEN_SIMULATION on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method MAINTENANCE_SCREEN_SORT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_SORT | Value transfer | Type reference (TYPE) | ABAP_SORTORDER_TAB | Tabelle für SORT itab BY (ABAP_SORTORDER_TAB) | 20070730 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method MAINTENANCE_SCREEN_SORT on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PASTE_REDUCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_DELETE | Value transfer | Type reference (TYPE) | WCTPC_INDEXTAB_TYPE | Tabelle der zu löschenden Einträge | 20120301 | ||
2 | ![]() |
IT_CLIPBOARD | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Zwischenablage | 20120301 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120301 | ||
4 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20120301 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120301 |
Method PASTE_REDUCE on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PHBLNR_INPUT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070822 | ||
2 | ![]() |
IS_ITM | Value transfer | Type reference (TYPE) | WCSWCITM | Struktur: Positionen | 20070823 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070822 | ||
4 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070822 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070822 |
Method PHBLNR_INPUT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PHBLNR_VALUE_HELP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_PHBLNR | Value transfer | Type reference (TYPE) | WCEPHBLNR | Schloss | 20070823 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070822 | ||
3 | ![]() |
IV_CCOBJ | Value transfer | Type reference (TYPE) | WCECCOBJ | Technisches Objekt | 20070823 | ||
4 | ![]() |
IV_CCTYP | Value transfer | Type reference (TYPE) | WCECCTYP | Typ der Position | 20070823 | ||
5 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070822 | ||
6 | ![]() |
IV_ITM_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Position) | 20070822 | ||
7 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070822 | ||
8 | ![]() |
IV_TGGRP | Value transfer | Type reference (TYPE) | WCETGGRP | Schaltgruppe | 20070823 |
Method PHBLNR_VALUE_HELP on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PREPARED_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070730 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
4 | ![]() |
IV_INFO | Value transfer | Type reference (TYPE) | WCEINFO | Meldung kann ausgegeben werden | 20110811 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method PREPARED_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_TAGGING_LIST_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
4 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method PRINT_TAGGING_LIST_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_TAG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
EV_SUPPRESS_PRINT | Value transfer | Type reference (TYPE) | WCEBOOLEAN | Boolesche Variable: Kein Ausdruck | 20110919 | ||
3 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
4 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
5 | ![]() |
IV_COPYFLG | Value transfer | Type reference (TYPE) | WCECOPYFLG | Kennzeichen: Kopie | 20070724 | ||
6 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
7 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
8 | ![]() |
IV_MULTIFLG | Value transfer | Type reference (TYPE) | WCEMULTIFLG | Kennzeichen: Mehrfachverwendbarkeit | 20070724 | ||
9 | ![]() |
IV_PREPRINTFLG | Value transfer | Type reference (TYPE) | WCEPREPRINTFLG | Kennzeichen: Vorabdruck | 20070724 |
Method PRINT_TAG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_TAG_REUSE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20101021 | ||
2 | ![]() |
IS_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMWA_TYPE | Betrachtete Position | 20101021 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20101021 |
Method PRINT_TAG_REUSE_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_TEST_TAG_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
EV_SUPPRESS_PRINT | Value transfer | Type reference (TYPE) | WCEBOOLEAN | Boolesche Variable: Kein Ausdruck | 20110919 | ||
3 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
4 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
5 | ![]() |
IV_COPYFLG | Value transfer | Type reference (TYPE) | WCECOPYFLG | Kennzeichen: Kopie | 20070724 | ||
6 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
7 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 | ||
8 | ![]() |
IV_MULTIFLG | Value transfer | Type reference (TYPE) | WCEMULTIFLG | Kennzeichen: Mehrfachverwendbarkeit | 20070724 |
Method PRINT_TEST_TAG_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_TEST_TAG_REUSE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20101021 | ||
2 | ![]() |
IS_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMWA_TYPE | Betrachtete Position | 20101021 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20101021 |
Method PRINT_TEST_TAG_REUSE_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method PRINT_UNTAGGING_LIST_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_ITM | Value transfer | Type reference (TYPE) | WCTP1_WCITMTAB_TYPE | Tabelle der betrachteten Positionen | 20070724 | ||
3 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
4 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method PRINT_UNTAGGING_LIST_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method RFC_DESTINATION_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_RFCDEST | Value transfer | Type reference (TYPE) | RFCDEST | RFC-Destination | 20070801 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method RFC_DESTINATION_GET on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method SELECTION_MODIFY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CT_CCOBJ | Value transfer | Type reference (TYPE) | WCTPC_CCOBJTAB_TYPE | Tabelle von technischen Objekten | 20070730 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 |
Method SELECTION_MODIFY on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method SWITCHING_SCREEN_SIMULATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
2 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method SWITCHING_SCREEN_SIMULATION on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method SWITCHING_SCREEN_SORT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_SORT | Value transfer | Type reference (TYPE) | ABAP_SORTORDER_TAB | Tabelle für SORT itab BY (ABAP_SORTORDER_TAB) | 20070724 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method SWITCHING_SCREEN_SORT on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method TAGGING_LIST_EXPORT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_WCAMC | Value transfer | Type reference (TYPE) | WCTP1_WCAMCTAB_TYPE | Protokoll der Schaltlisten (Kopfdaten) | 20070724 | ||
3 | ![]() |
IT_WCAME | Value transfer | Type reference (TYPE) | WCTP1_WCAMETAB_TYPE | (temporäres) Protokoll der Schaltlisten (Positionen) | 20070724 | ||
4 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
5 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
6 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method TAGGING_LIST_EXPORT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method UNTAGGABLE_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Value transfer | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
3 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method UNTAGGABLE_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method UNTAGGING_LIST_EXPORT_CHECK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_RETURN_VALUE | Call by reference | Type reference (TYPE) | SYSUBRC | Rückgabewert | 20070724 | ||
2 | ![]() |
IT_WCAMC | Value transfer | Type reference (TYPE) | WCTP1_WCAMCTAB_TYPE | Protokoll der Schaltlisten (Kopfdaten) | 20070724 | ||
3 | ![]() |
IT_WCAME | Value transfer | Type reference (TYPE) | WCTP1_WCAMETAB_TYPE | (temporäres) Protokoll der Schaltlisten (Positionen) | 20070724 | ||
4 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070724 | ||
5 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070724 | ||
6 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070724 |
Method UNTAGGING_LIST_EXPORT_CHECK on Interface IF_EX_BADI_WCM_OPWC has no exception.
Method USRFLD_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_USRFLD | Value transfer | Type reference (TYPE) | WCTP1_USRFLD_TYPE | Benutzerfeld | 20070730 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20070730 | ||
3 | ![]() |
IV_HDR_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Kopf) | 20070730 | ||
4 | ![]() |
IV_ITM_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer (Position) | 20070730 | ||
5 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20070730 | ||
6 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20070730 |
Method USRFLD_GET on Interface IF_EX_BADI_WCM_OPWC has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in | 603 |