SAP ABAP Interface /SAPCND/IF_EX_TST_UNIT_USG (Business add-in interface /SAPCND/IF_EX_TST_UNIT_USG)
Hierarchy
SAP_AP (Software Component) SAP Application Platform
   AP-PRC-CON (Application Component) Condition Technique
     /SAPCND/TEST_T (Package) Test tools for condition technique
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  /SAPCND/CL_EX_TST_UNIT_USG BAdI Class /SAPCND/CL_EX_TST_UNIT_USG 20090312
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_FG_UNIT_TEST Imp. class for BAdI imp. FG_UNIT_TEST 20050216
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_MM_UNIT_TEST Imp. class for BAdI imp. MM_UNIT_TEST 20050224
4 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_PD_UNIT_TEST Imp. class for BAdI imp. PD_UNIT_TEST 20050209
5 Interface implementation (CLASS c. INTERFACES i_ref)  CL_IM_PR_UNIT_TEST Imp. class for BAdI imp. PR_UNIT_TEST 20050131
Properties
Interface /SAPCND/IF_EX_TST_UNIT_USG  
Short Description Business add-in interface /SAPCND/IF_EX_TST_UNIT_USG    
General Data
Package /SAPCND/TEST_T   Test tools for condition technique 
Created 20050131   SAP 
Last changed 20110810   SAP 
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 CTCUS Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Interface /SAPCND/IF_EX_TST_UNIT_USG has no interface.
Friends
Interface /SAPCND/IF_EX_TST_UNIT_USG has no friend.
Attributes
Interface /SAPCND/IF_EX_TST_UNIT_USG has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 ADDN_OBJ_CHECKS Instance method Public Method Checks for addn customizing for the usage. ex. copy for PR 20050602
2 ADD_SCALE_LINE Instance method Public Method Adds a line to an existing scale 20090324
3 CHK_USAGE_TO_TEST Instance method Public Method Check if the usage is registered for masterdata unit test 20050131
4 CLEAR_SCALE_TABLES Instance method Public Method Clears the scales tables. 20090324
5 COND_TYPE Instance method Public Method Checks all the condition types for this usage 20050523
6 DELETE_SCALE_LINE Instance method Public Method Deletes a line from an existing scale 20090324
7 GET_SCALE_IS_TEST_RELEVANT Instance method Public Method Is Scale relevant for testing? 20090312
8 GET_SCALE_TABLES Instance method Public Method Fills the scales tables. 20090324
9 GET_USAGE_CHANGE_VALUES Instance method Public Method Fills the usage fields to be changed with valuesmasterdataUT 20050209
10 GET_USAGE_FIELD_VALUES Instance method Public Method Fills the usage fields in the wsis masterdata unit test 20050207
11 PROCEDURE_CHECK Instance method Public Method Checks all the procedures for this usage 20050523
Events
Interface /SAPCND/IF_EX_TST_UNIT_USG has no event.
Types
Interface /SAPCND/IF_EX_TST_UNIT_USG has no local type.
Method Signatures

Method ADDN_OBJ_CHECKS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20050602
2 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Parameter FLT_VAL of method ADDN_OBJ_CHECKS 20050602
3 Importing IT_APPLNS Value transfer Type reference (TYPE) /SAPCND/T681A_S_T Applications 20080808

Method ADDN_OBJ_CHECKS on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method ADD_SCALE_LINE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_WORKING_SET Call by reference Object reference (TYPE REF TO) DATA 20090324
2 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20090324
3 Exporting EV_SCALE_ID Call by reference Type reference (TYPE) /SAPCND/SCALE_ID Scale ID 20090324
4 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Usage for Condition Technique 20090324
5 Importing IV_IS_EXT_REP Call by reference Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090324

Method ADD_SCALE_LINE on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method CHK_USAGE_TO_TEST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_CHK_USAGE_READY Call by reference Type reference (TYPE) /SAPCND/BOOLEAN Boolesche Variable 20050202
2 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE 20050131

Method CHK_USAGE_TO_TEST on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method CLEAR_SCALE_TABLES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_WORKING_SET Call by reference Object reference (TYPE REF TO) DATA 20090324
2 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20090324
3 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Usage for Condition Technique 20090324
4 Importing IV_IS_EXT_REP Call by reference Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090324

Method CLEAR_SCALE_TABLES on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method COND_TYPE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB 20050524
2 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE 20050523
3 Importing IT_APPLNS Value transfer Type reference (TYPE) /SAPCND/T681A_S_T Applications 20080808

Method COND_TYPE on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method DELETE_SCALE_LINE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_WORKING_SET Call by reference Type reference (TYPE) DATA 20090324
2 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20090324
3 Exporting EV_SCALE_ID Call by reference Type reference (TYPE) /SAPCND/SCALE_ID Scale ID 20090324
4 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Parameter FLT_VAL of method DELETE_SCALE_LINE 20090324
5 Importing IV_IS_EXT_REP Call by reference Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090324

Method DELETE_SCALE_LINE on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method GET_SCALE_IS_TEST_RELEVANT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_SCALE_IS_TEST_RELEVANT Value transfer Type reference (TYPE) /SAPCND/BOOLEAN Boolean Variable 20090312
2 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Parameter FLT_VAL of method GET_SCALE_IS_TEST_RELEVANT 20090312

Method GET_SCALE_IS_TEST_RELEVANT on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method GET_SCALE_TABLES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_WORKING_SET Call by reference Object reference (TYPE REF TO) DATA 20090324
2 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB Table with BAPI Return Information 20090324
3 Exporting EV_SCALE_BASE_TYPE Call by reference Type reference (TYPE) /SAPCND/SCALE_BASE_TYPE Scale Base Type 20090324
4 Exporting EV_SCALE_ID Call by reference Type reference (TYPE) /SAPCND/SCALE_ID Scale ID 20090324
5 Exporting EV_SCALE_NOT_TEST_RELEVANT Value transfer Type reference (TYPE) /SAPCND/BOOLEAN Boolean Variable 20090324
6 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE Usage for Condition Technique 20090324
7 Importing IV_IS_EXT_REP Call by reference Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090324

Method GET_SCALE_TABLES on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method GET_USAGE_CHANGE_VALUES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_CHANGE_ATTR_VALUE_TAB Call by reference Type reference (TYPE) /SAPCND/T_ATTRIB_VALUE_INT Attributwertpaar in interner Anzeige 20050209
2 Exporting ET_CHANGE_ATTR_VALUE_TAB_EXT Call by reference Type reference (TYPE) /SAPCND/T_ATTRIB_VALUE_EXT Attribute Value Pair in External Display 20090313
3 Exporting EV_IS_REPLACE Call by reference Type reference (TYPE) /SAPCND/BOOLEAN Boolesche Variable 20050217
4 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE 20050209
5 Importing IV_IS_EXT_REP Value transfer Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090313

Method GET_USAGE_CHANGE_VALUES on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method GET_USAGE_FIELD_VALUES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_WORKING_SET Call by reference Object reference (TYPE REF TO) DATA 20050207
2 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB 20050207
3 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE 20050207
4 Importing IT_T688C Call by reference Type reference (TYPE) /SAPCND/T688C_S_T 20050207
5 Importing IV_IS_EXT Call by reference Type reference (TYPE) /SAPCND/BOOLEAN CTCUS_FALSE Boolean Variable 20090312

Method GET_USAGE_FIELD_VALUES on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.

Method PROCEDURE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_BAPIRET Call by reference Type reference (TYPE) BAPIRETTAB 20050523
2 Importing FLT_VAL Value transfer Type reference (TYPE) /SAPCND/USAGE 20050523
3 Importing IT_APPLNS Value transfer Type reference (TYPE) /SAPCND/T681A_S_T Applications 20080808

Method PROCEDURE_CHECK on Interface /SAPCND/IF_EX_TST_UNIT_USG has no exception.
History
Last changed by/on SAP  20110810 
SAP Release Created in 700