Hierarchy
⤷ QM-QC-IS (Application Component) Information System
⤷ QG01 (Package) QM quality inspection analysis
Basic Data
Data Element | QM_MONITOR |
Short Description | Selection Field for Monitor Function Reference Field |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | I_SORT | |
Data Type | CHAR | Character String |
Length | 1 | |
Decimal Places | 0 | |
Output Length | 1 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Ref. field |
Medium | 18 | Ref. field monitor |
Long | 22 | Ref. field monitor |
Heading | 1 | T |
Documentation
Definition
Key that determines the monitor reference.
Use
If you choose a reference field, the monitor color indicates the corresponding status for the reference object.
If you do not choose a reference field, the monitor is not displayed.
Procedure
Examples
Dependencies
Supplementary Documentation - QM_MONITOR0001
Use
If you choose a reference field, the color of the monitor (traffic light) indicates the current status of the reference object.
If you do not choose a reference field, the monitor is not displayed.
Examples
The color of the monitor has the following meaning, depending on the monitor control reference object:
Reference object "Inspection lot creation"
Color Meaning
- Red Inspection lot creation for physical sample not possible,
or not allowed.
Possible causes:
The last or current inspection lot for the sample
has not been closed.
There is no material known for the physical sample.
No sample size is maintained for the physical sample.
The unit of measure for the physical sample cannot be
converted into the base unit of measure for the material.
- Yellow Inspection lot creation for the physical sample not
possible.
The physical sample does not have the status 'released'.
No inspection type is maintained for origin 15.
Inspection type not active in the material master.
- Green Inspection lot creation for the physical sample allowed.
Reference object "Status"
Color Meaning
- Red Physical sample has the status "Locked".
- Yellow Physical sample has the status "Created".
- Green Physical sample has the status "Release".
Reference object "Storage deadline"
Color Meaning
- Red The storage date is exceeded.
- Yellow The storage date is the current date.
- Green The storage date has not yet been reached.
History
Last changed by/on | SAP | 19990104 |
SAP Release Created in |