Hierarchy
⤷ IS-U-DM-MR (Application Component) Meter Reading
⤷ EE16 (Package) IS-U: Meter Reading Order Creation
Basic Data
Data Element | E_ZWZUART |
Short Description | Register relationship type |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | E_ZWZUART | |
Data Type | NUMC | Character string with only digits |
Length | 2 | |
Decimal Places | 0 | |
Output Length | 2 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | RR type |
Medium | 15 | Reg. rel. type |
Long | 20 | Register rel. type |
Heading | 4 | RRT |
Documentation
Definition
Type of register relationship
Use
Note the following:
- Active/reactive relationship 01
The system establishes a relationship between the meter reading difference of the reactive register and the active register during validations.
- Serial switching relationship 02
The total meter reading differences of secondary meters is subtracted from the meter reading difference of the primary meter during billing.
- On-/off peak relationship 03
A relationship is established between the meter reading difference of the on-peak register and the meter reading difference of the off-peak register during validations.
- Control relationship 04
The system compares the total meter reading differences of normal registers with the meter reading difference of the control register during validations.
- Volume correction factor relationship 05
The volume correction factor for the register with operation code reg. passes on vol. corr. factor is allocated to the register with operation code reg. transfers vol. corr. factor.
If you want to use the volume correction factor relationship, you must select the special volume correction factor procedure reg. rel. VCF for the register with operation code reg. transfers vol. corr. factor.
- Volume correction factor calculation relationship 06
Volume correction factor VCF is obtained using the formula: meter reading difference of standard volume meter, divided by the meter reading difference of operating volume meter.
In order to calculate the factor using the above formula, you must create a register relationship of type volume correction factor calculation. You must also select special volume correction factor procedure reg. rel. VCF for the operating volume meter.
- Resetting register relationship 07
During validation, the system determines which resetting register is to count the resettings of a balancing register.
- Pulse relationship 08
Specifies which register is controlled by pulses from another register.
- Usage hour relationship 09
Specifies which register is used for calculating usage hours.
For more information, see Conditions for processing register relationships.
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in |