Basic Data
Data Element | E_OPCODE |
Short Description | Operation code: Role of register in relationship |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | E_OPCODE | |
Data Type | NUMC | Character string with only digits |
Length | 2 | |
Decimal Places | 0 | |
Output Length | 2 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Oper. code |
Medium | 15 | Operation code |
Long | 20 | Operation code |
Heading | 3 | OC |
Documentation
Use
Specifies how the meter reading difference of the register is incorporated into the billing variable and therefore into billing.
Note the following:
- Register adopts volume correction factor 01 in register relationship type volume correction factor relationship
The register adopts the volume correction factor of the register with operation code 02.
- Register passes on volume correction factor 02 in the case of register relationship type volume correction factor relationship
The register passes on the volume correction factor to registers with operation code 01.
- Primary register 03 in a serial switching relationship
The register belongs to the primary meter.
- Primary register 04 in a serial switching relationship
The register belongs to the secondary meter
- Register 05 in a control relationship
The register belongs to controlled registers. All registers with operation code 05 are added together and compared to the control register with operation code 06.
- Control register 06 in a control relationship
The register controls all registers with operation code 05.
- 09 register assigned standard volume in a volume correction factor calculation relationship
The meter reading difference of the register is used in the volume correction factor formula (VCF = standard volume/operating volume). The volume correction is calculated during gas billing. The factor is assigned to the register in the same relationship with operation code 10 instead of the register with operation code 09.
- Register 10 assigned operating volume in the case of a volume correction factor calculation relationship
The meter reading difference of the register is used in the volume correction factor formula (VCF = standard volume/operating volume). The factor is calculated during gas billing and allocated to the register with operation code 10.
- Primary rate register 11 in on-/off peak relationship.
The register contains the primary rate.
- Secondary rate register 12 in on-/off peak relationship.
The register has the secondary rate.
- Register 13 in resetting relationship
The register counts the number of resettings.
- Reset register 14 in resetting relationship
The register is deferred during meter reading.
- Pulse sender 15 in pulse relationship
The register sends pulses to other registers.
- Pulse receiver 15 in pulse relationship
The register receives pulses from another register. Its reading increases in relation to a pulse constant.
For more information, see Conditions for processing register relationships