SAP ABAP Data Element DO_DEPCAL_SECREG (Do not include secondary meter in dependent validation)
Hierarchy
IS-UT (Software Component) SAP Utilities/Telecommunication
   IS-U-DM-MR (Application Component) Meter Reading
     EE17 (Package) IS-U: Meter Reading Data Entry
Basic Data
Data Element DO_DEPCAL_SECREG
Short Description Do not include secondary meter in dependent validation  
Data Type
Category of Dictionary Type D   Domain
Type of Object Referenced     No Information
Domain / Name of Reference Type KENNZX    
Data Type CHAR   Character String 
Length 1    
Decimal Places 0    
Output Length 1    
Value Table      
Further Characteristics
Search Help: Name    
Search Help: Parameters    
Parameter ID   
Default Component name    
Change document    
No Input History    
Basic direction is set to LTR    
No BIDI Filtering    
Field Label
  Length  Field Label  
Short 10 No SMDV 
Medium 15 No DV for SM 
Long 20 No DV for sec. meter 
Heading NSM 
Documentation

Definition

If you select this field, the dependent validation for serial switching is only performed for the primary meter. However, you can only do this once all meter readings have been entered for the secondary installations. Until that time, the primary meter will have status Undergone independent validation.

The secondary meters only undergo independent validations. If meter readings from the secondary installation have undergone independent validations and are plausible or released, then the secondary installation can be billed. This means that the secondary installation can be billed before all meter readings from the meters switched series have been entered. However, you can only correct the meter readings before the installation has been billed. It is advisable to wait until all readings from meters switched in series have been entered before billing the installation.

Use

You select this field if an installation possesses a large number of meters switched in series. In this case, only the primary installation undergoes a dependent validation.

If you do not select this field, all registers undergo independent validations. If a meter reading is entered for a secondary installation, it undergoes an independent validation. If it is plausible, the reading undergoes a dependent validation. However, the dependent validation cannot take place until all meter readings have been entered for all registers. Until that time, the secondary installation will have the status Undergone independent validation and cannot be billed. The secondary installation cannot be billed until all readings from meters switched in series have been entered and have undergone dependent validations.

Dependencies

Example

History
Last changed by/on SAP  20050224 
SAP Release Created in 462