Hierarchy
⤷ CA-FS-MKD (Application Component) Basic Market Data
⤷ /BA1/F4_BASIS_BAPI (Package) BAPI Basis Package
Basic Data
Data Element | /BA1/BAPIF4_DTE_INC_ENT_ACTIVE |
Short Description | Indicator: Update of Possibly Temp.Inconsist.Entities Active |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | /BA1/F4_DO_BOOLEAN | |
Data Type | CHAR | Character String |
Length | 1 | |
Decimal Places | 0 | |
Output Length | 1 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | WRITEINCENT | |
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Inc. Ent. |
Medium | 19 | Update Incon. Ent. |
Long | 40 | Update of Possibly Temp.Inconsist.Ents |
Heading | 51 | Update of Possibly Temp. Inconsist. Entities Active |
Documentation
Definition
The correction server is available in Bank Analyzer only and has no meaning in other applications.
Update of the entities that are possibly temporarily inconsistent in (PTIE) online processing.
- 'X' - Is activated, whereby customer settings for the dependencies are used.
- ' ' - Is deactivated.
If this indicator is activated, then the data flow management must also be activated. If this is the case, then the PTIEs are determined in a correction, and saved in the database.
If this indicator is deactivated, then the PTIEs are determined during a correction, but are not saved in the database. Therefore, there are restrictions in the reporting functions for corrections. This means that PTIE entries cannot be found in the database for evaluation.
Unlike the reporting of corrections at a later time, the notification is sent when the correction is made. Therefore, PTIEs can be found from the data flow management and sent to the notifier. However, this requires the activation of the data flow management first.
It is recommended that you set this switch, and the switch for the data flow management. This switch needs to be activated for online processing, but deactivated for mass processing to help reduce the system load after the settings are overridden.
The WRITE_CORRECTION must be active in the /BA1/FK_STR_CUST_SETTING structure during mass processing, so that the system can interpret the WRITE_INC_ENT field.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 20 |