SAP ABAP Class IF_UMM_DOMAINOBJECT (Interface for Domain Object)
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_COCKPIT | MC Cockpit Class | 20001030 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_FRAME | MC Frame Class | 20001030 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_LOGICAL_VIEW | MC Logical View Class | 20001030 |
| 4 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_MC_MANAGER | Transient Class Managing Different Cockpits | 20001030 |
| 5 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_WALL | MC Wall Class | 20001030 |
Properties
| Class | IF_UMM_DOMAINOBJECT | |
| Short Description | Interface for Domain Object | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | ||
| Created | 20001025 | SAP |
| Last change | 20041006 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class IF_UMM_DOMAINOBJECT has no forward declaration.
Interfaces
Class IF_UMM_DOMAINOBJECT has no interface implemented.
Friends
Class IF_UMM_DOMAINOBJECT has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Public | Object reference (TYPE REF TO) | CL_UMM_BIC | MC : BIC - Interface | 20010622 | |||
| 2 | Instance attribute | Public | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Access to BW Transaction Data for Frames | 20010306 | |||
| 3 | Instance attribute | Public | Object reference (TYPE REF TO) | IF_UMM_DOMAINOBJECT | 20001025 | ||||
| 4 | Instance attribute | Public | Type reference (TYPE) | UMC_Y_LTXT | 20001025 | ||||
| 5 | Instance attribute | Public | Type reference (TYPE) | UMC_Y_MTXT | 20001025 | ||||
| 6 | Instance attribute | Public | Type reference (TYPE) | UMM_Y_OBJNAME | 20001025 | ||||
| 7 | Instance attribute | Public | Type reference (TYPE) | UMC_Y_STATUS | 20001025 | ||||
| 8 | Instance attribute | Public | Type reference (TYPE) | UMC_Y_STXT | 20001025 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | 20010627 | ||
| 2 | Instance method | Public | Method | 20031128 | ||
| 3 | Instance method | Public | Method | 20001025 | ||
| 4 | Instance method | Public | Method | 20001025 | ||
| 5 | Instance method | Public | Method | 20001025 |
Events
Class IF_UMM_DOMAINOBJECT has no event.
Types
Class IF_UMM_DOMAINOBJECT has no local type.
Method Signatures
Method GET_CHARS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_CHARS | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Dimension | 20010627 | |||
| 2 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010627 | |||
| 3 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20010627 | |||
| 4 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20010627 | |||
| 5 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010627 | |||
| 6 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010627 | |||
| 7 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010627 | |||
| 8 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010627 | |||
| 9 | I_MODE | Call by reference | Type reference (TYPE) | N | '1' | 20010720 | |||
| 10 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010627 |
Method GET_CHARS on class IF_UMM_DOMAINOBJECT has no exception.
Method GET_FRAME Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ER_FRAME | Call by reference | Object reference (TYPE REF TO) | CL_UMM_FRAME | MC Frame Class | 20031128 | |||
| 2 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20031128 | |||
| 3 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20031128 | |||
| 4 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20031128 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | 20031128 |
Method GET_PARENT Signature
Method GET_PARENT on class IF_UMM_DOMAINOBJECT has no parameter.
Method GET_PARENT on class IF_UMM_DOMAINOBJECT has no exception.
Method GET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_STATUS | Call by reference | Type reference (TYPE) | UMM_Y_PSTATUS | Status eines Frames (Präsentation) | 20001110 | |||
| 2 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010323 | |||
| 3 | IT_DRILLDOWN_DET | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Dimension | 20010628 | |||
| 4 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20001110 | |||
| 5 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20001110 | |||
| 6 | I_BW_STATUS | Call by reference | Type reference (TYPE) | UMM_Y_STATGEN | Dummy für B20 int1 (überall lokal!) | 20010323 | |||
| 7 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010323 | |||
| 8 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010323 | |||
| 9 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010323 | |||
| 10 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010323 | |||
| 11 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010323 |
Method GET_STATUS on class IF_UMM_DOMAINOBJECT has no exception.
Method SET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010329 | |||
| 2 | IT_DRILLDOWN_DET | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Drilldown Characteristics | 20010628 | |||
| 3 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20001110 | |||
| 4 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20001110 | |||
| 5 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010329 | |||
| 6 | I_DEFAULT_STATUS | Call by reference | Type reference (TYPE) | CHAR1 | '0' | '0','1','2' | 20001110 | ||
| 7 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010329 | |||
| 8 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010329 | |||
| 9 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010329 | |||
| 10 | I_STATUS | Value transfer | Type reference (TYPE) | UMM_Y_PSTATUS | Einstelliges Kennzeichen | 20001030 | |||
| 11 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010329 |
Method SET_STATUS on class IF_UMM_DOMAINOBJECT has no exception.
History
| Last changed by/on | SAP | 20041006 |
| SAP Release Created in |