SAP ABAP Interface IF_UMM_DOMAINOBJECT (Interface for Domain Object)
Hierarchy
☛
SEM-BW (Software Component) SEM-BW: Strategic Enterprise Management
⤷
FIN-SEM-CPM-MC (Application Component) Management Cockpit
⤷
UMM (Package) SEM-CPM: Management Cockpit
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_COCKPIT | MC Cockpit Class | 20001030 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_FRAME | MC Frame Class | 20001030 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_LOGICAL_VIEW | MC Logical View Class | 20001030 |
| 4 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_MC_MANAGER | Transient Class Managing Different Cockpits | 20001030 |
| 5 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_UMM_WALL | MC Wall Class | 20001030 |
Properties
| Interface | IF_UMM_DOMAINOBJECT | |
| Short Description | Interface for Domain Object |
General Data
| Package | UMM | SEM-CPM: Management Cockpit |
| Created | 20001025 | SAP |
| Last changed | 20041006 | SAP |
| Unicode checks active |
Forward declarations
Interface IF_UMM_DOMAINOBJECT has no forward declaration.
Interfaces
Interface IF_UMM_DOMAINOBJECT has no interface.
Friends
Interface IF_UMM_DOMAINOBJECT has no friend.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | MR_BIC | Instance attribute | Public | Object reference (TYPE REF TO) | CL_UMM_BIC | MC : BIC - Interface | 20010622 | ||
| 2 | MR_BW | Instance attribute | Public | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Access to BW Transaction Data for Frames | 20010306 | ||
| 3 | MR_PARENT | Instance attribute | Public | Object reference (TYPE REF TO) | IF_UMM_DOMAINOBJECT | 20001025 | |||
| 4 | M_LTXT | Instance attribute | Public | Type reference (TYPE) | UMC_Y_LTXT | 20001025 | |||
| 5 | M_MTXT | Instance attribute | Public | Type reference (TYPE) | UMC_Y_MTXT | 20001025 | |||
| 6 | M_NAME | Instance attribute | Public | Type reference (TYPE) | UMM_Y_OBJNAME | 20001025 | |||
| 7 | M_STATUS | Instance attribute | Public | Type reference (TYPE) | UMC_Y_STATUS | 20001025 | |||
| 8 | M_STXT | Instance attribute | Public | Type reference (TYPE) | UMC_Y_STXT | 20001025 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | 20010627 | ||
| 2 | Instance method | Public | Method | 20031128 | ||
| 3 | Instance method | Public | Method | 20001025 | ||
| 4 | Instance method | Public | Method | 20001025 | ||
| 5 | Instance method | Public | Method | 20001025 |
Events
Interface IF_UMM_DOMAINOBJECT has no event.
Types
Interface IF_UMM_DOMAINOBJECT has no local type.
Method Signatures
Method GET_CHARS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_CHARS | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Dimension | 20010627 | |||
| 2 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010627 | |||
| 3 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20010627 | |||
| 4 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20010627 | |||
| 5 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010627 | |||
| 6 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010627 | |||
| 7 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010627 | |||
| 8 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010627 | |||
| 9 | I_MODE | Call by reference | Type reference (TYPE) | N | '1' | 20010720 | |||
| 10 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010627 |
Method GET_CHARS on Interface IF_UMM_DOMAINOBJECT has no exception.
Method GET_FRAME Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ER_FRAME | Call by reference | Object reference (TYPE REF TO) | CL_UMM_FRAME | MC Frame Class | 20031128 | |||
| 2 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20031128 | |||
| 3 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20031128 | |||
| 4 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20031128 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | 20031128 |
Method GET_PARENT Signature
Method GET_PARENT on Interface IF_UMM_DOMAINOBJECT has no parameter.
Method GET_PARENT on Interface IF_UMM_DOMAINOBJECT has no exception.
Method GET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_STATUS | Call by reference | Type reference (TYPE) | UMM_Y_PSTATUS | Status eines Frames (Präsentation) | 20001110 | |||
| 2 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010323 | |||
| 3 | IT_DRILLDOWN_DET | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Dimension | 20010628 | |||
| 4 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20001110 | |||
| 5 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20001110 | |||
| 6 | I_BW_STATUS | Call by reference | Type reference (TYPE) | UMM_Y_STATGEN | Dummy für B20 int1 (überall lokal!) | 20010323 | |||
| 7 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010323 | |||
| 8 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010323 | |||
| 9 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010323 | |||
| 10 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010323 | |||
| 11 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010323 |
Method GET_STATUS on Interface IF_UMM_DOMAINOBJECT has no exception.
Method SET_STATUS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IR_BW | Call by reference | Object reference (TYPE REF TO) | CL_UMM_BW_FRAMES_MC | MC: Zugriff auf BW-Bewegungsdaten für Frames | 20010329 | |||
| 2 | IT_DRILLDOWN_DET | Call by reference | Type reference (TYPE) | UMM_YT_CHAR | Table type for Drilldown Characteristics | 20010628 | |||
| 3 | IT_DRILLDOWN_LIST | Call by reference | Type reference (TYPE) | UMM_YT_DRILLDOWN | Table type for Drilldown Characteristics | 20001110 | |||
| 4 | IT_RUNTIME_VAR | Call by reference | Type reference (TYPE) | UMM_YT_RUNTIME_VAR | Table Type for runtime Variable | 20001110 | |||
| 5 | I_CONAME | Call by reference | Type reference (TYPE) | UMM_Y_CONAME | Technischer Name eines Management Cockpits | 20010329 | |||
| 6 | I_DEFAULT_STATUS | Call by reference | Type reference (TYPE) | CHAR1 | '0' | '0','1','2' | 20001110 | ||
| 7 | I_FRNAME | Call by reference | Type reference (TYPE) | UMM_Y_FRNAME | Technischer Name eines Frames | 20010329 | |||
| 8 | I_FRNO | Call by reference | Type reference (TYPE) | UMM_Y_FRNO | Nummer eines Frames in einer Logischen Sicht | 20010329 | |||
| 9 | I_LVNO | Call by reference | Type reference (TYPE) | UMM_Y_LVNO | Nummer einer Logischen Sicht in der Wand | 20010329 | |||
| 10 | I_STATUS | Value transfer | Type reference (TYPE) | UMM_Y_PSTATUS | Einstelliges Kennzeichen | 20001030 | |||
| 11 | I_WANO | Call by reference | Type reference (TYPE) | UMM_Y_WANO | Nummer einer Wand im Management Cockpit | 20010329 |
Method SET_STATUS on Interface IF_UMM_DOMAINOBJECT has no exception.
History
| Last changed by/on | SAP | 20041006 |
| SAP Release Created in |