SAP ABAP Class CL_XMS_MSG_FILTER_GRID (CL_XMS_MSG_FILTER_GRID)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-XI-IS-IEN (Application Component) Integration Engine
⤷
SXMSJOB (Package) XI: Time-Driven Message Processing
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_XMS_BASIS_GRID | Basis Grid | 20040722 |
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_XMS_MSG_FILTER_GRID_JOB | 20050628 | |
| 2 | Inheritance (c INHERITING FROM c_ref) | CL_XMS_MSG_FILTER_GRID_QUEUE | Queue Prefix Filter Display | 20040324 |
Properties
| Class | CL_XMS_MSG_FILTER_GRID | |
| Short Description | ||
| Super Class | CL_XMS_BASIS_GRID | Basis Grid |
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | SXMSJOB | XI: Time-Driven Message Processing |
| Created | 20030527 | SAP |
| Last change | 20110908 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_XMS_MSG_FILTER_GRID has no interface implemented.
Friends
| # | Friend | Modeled only | Created on | Description |
|---|---|---|---|---|
| 1 | CL_XMS_UCOMM_FILTER_REFRESH | 20050711 |
Attributes
Methods
Events
Class CL_XMS_MSG_FILTER_GRID has no event.
Types
Class CL_XMS_MSG_FILTER_GRID has no local type.
Method Signatures
Method ADJUST_DISPLAY_FIELDS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FILTER_DISP_WA | Call by reference | Type reference (TYPE) | SXMS_MSG_FILTER | Grid Ausgabestruktur | 20031209 |
Method ADJUST_DISPLAY_FIELDS on class CL_XMS_MSG_FILTER_GRID has no exception.
Method CHECK_SAVED Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | RET | Value transfer | Type reference (TYPE) | CHAR1 | 20030605 |
Method CHECK_SAVED on class CL_XMS_MSG_FILTER_GRID has no exception.
Method CLEAR_WORK_AREA Signature
Method CLEAR_WORK_AREA on class CL_XMS_MSG_FILTER_GRID has no parameter.
Method CLEAR_WORK_AREA on class CL_XMS_MSG_FILTER_GRID has no exception.
Method CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_APPLOGPARENT | Call by reference | Object reference (TYPE REF TO) | CL_GUI_CONTAINER | 20040325 | ||||
| 2 | I_APPL_EVENTS | Call by reference | Type reference (TYPE) | CHAR01 | 20040325 | ||||
| 3 | I_GRAPHICSPARENT | Call by reference | Object reference (TYPE REF TO) | CL_GUI_CONTAINER | 20040325 | ||||
| 4 | I_LIFETIME | Call by reference | Type reference (TYPE) | I | 20040325 | ||||
| 5 | I_NAME | Call by reference | Type reference (TYPE) | STRING | 20040325 | ||||
| 6 | I_PARENT | Call by reference | Object reference (TYPE REF TO) | CL_GUI_CONTAINER | 20040325 | ||||
| 7 | I_PARENTDBG | Call by reference | Object reference (TYPE REF TO) | CL_GUI_CONTAINER | 20040325 | ||||
| 8 | I_SHELLSTYLE | Call by reference | Type reference (TYPE) | I | 20040325 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Error Creating Control | 20040325 | ||
| 2 | Error Initializing Control | 20040325 | ||
| 3 | Error Linking Control | 20040325 | ||
| 4 | Error Creating DataProvider Control | 20040325 |
Method DEACTIVATE_FIELD_QUEUE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FIELD_TAB | Value transfer | Type reference (TYPE) | SCMG_TT_SVAL | Tabellentyp für SVAL | 20050629 |
Method DEACTIVATE_FIELD_QUEUE on class CL_XMS_MSG_FILTER_GRID has no exception.
Method DELETE_FILTER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | MSGFIL_WA | Call by reference | Type reference (TYPE) | SXMSMSGDEF | Message Defintion | 20040329 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20040329 |
Method DISPLAY_POPUP Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PRESET_FILTER_WA | Call by reference | Type reference (TYPE) | SXMS_MSG_FILTER | Grid Ausgabestruktur | 20040402 | |||
| 2 | UCOMM | Call by reference | Type reference (TYPE) | SY-UCOMM | Bildschirmbilder, Funktionscode, der PAI ausgelöst hat | 20040402 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20040402 |
Method GET_DETAILS_TAB Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DETAILS_TAB | Value transfer | Type reference (TYPE) | SXMS_NAME_VALUE_TTYP | TTYP für SXMS_NAME_VALUE | 20061012 | |||
| 2 | INTERFACE | Call by reference | Type reference (TYPE) | SXMSINTERFACE | Sender/Empfänger-Definition | 20061012 |
Method GET_DETAILS_TAB on class CL_XMS_MSG_FILTER_GRID has no exception.
Method INFO_ON_ACTIVATE Signature
Method INFO_ON_ACTIVATE on class CL_XMS_MSG_FILTER_GRID has no parameter.
Method INFO_ON_ACTIVATE on class CL_XMS_MSG_FILTER_GRID has no exception.
Method INFO_ON_CREATE_AND_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | JOB_ID | Call by reference | Type reference (TYPE) | SXMSJOB | Job-ID | 20040325 |
Method INFO_ON_CREATE_AND_INSERT on class CL_XMS_MSG_FILTER_GRID has no exception.
Method MOVE_SEQUENCE Signature
Method MOVE_SEQUENCE on class CL_XMS_MSG_FILTER_GRID has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20040325 |
Method ON_SND_RCV_ID_DOUBLE_CLICK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ES_ROW_NO | Call by reference | Attribute reference (LIKE) | 20061004 | |||||
| 2 | E_COLUMN | Call by reference | Attribute reference (LIKE) | 20061004 | |||||
| 3 | E_ROW | Call by reference | Attribute reference (LIKE) | 20061004 |
Method ON_SND_RCV_ID_DOUBLE_CLICK on class CL_XMS_MSG_FILTER_GRID has no exception.
Method PERFORM_TASK Signature
Method PERFORM_TASK on class CL_XMS_MSG_FILTER_GRID has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XMS: Ausnahmeklasse für Systemfehler | 20030602 |
Method POPUP_ACK_TEST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FIELD_TAB | Value transfer | Type reference (TYPE) | SCMG_TT_SVAL | Tabellentyp für SVAL | 20050629 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20060110 |
Method POPUP_INBOUND_TEST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FIELD_TAB | Value transfer | Type reference (TYPE) | SCMG_TT_SVAL | 20030630 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20030929 |
Method POPUP_REFRESH Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | J_N | Value transfer | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20050701 |
Method POPUP_REFRESH on class CL_XMS_MSG_FILTER_GRID has no exception.
Method POPUP_TEST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FIELD_TAB | Value transfer | Type reference (TYPE) | SCMG_TT_SVAL | 20030627 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | XI: Systemfehler | 20030929 |
Method POPUP_TEST_INIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FIELD_TAB | Call by reference | Type reference (TYPE) | SCMG_TT_SVAL | Tabellentyp für SVAL | 20040218 |
Method POPUP_TEST_INIT on class CL_XMS_MSG_FILTER_GRID has no exception.
Method REFRESH_COMMAND Signature
Method REFRESH_COMMAND on class CL_XMS_MSG_FILTER_GRID has no parameter.
Method REFRESH_COMMAND on class CL_XMS_MSG_FILTER_GRID has no exception.
Method SET_WORK_AREA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | INDEX | Call by reference | Type reference (TYPE) | LVC_S_ROW-INDEX | Index interner Tabellen | 20050712 | |||
| 2 | RET | Value transfer | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20050713 | |||
| 3 | TASK | Call by reference | Type reference (TYPE) | SY-UCOMM | Funktionscode, der PAI ausgelöst hat | 20050712 |
Method SET_WORK_AREA on class CL_XMS_MSG_FILTER_GRID has no exception.
Method TEST_MESSAGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | TESTDATA | Call by reference | Type reference (TYPE) | SXMS_TESTDATA_IS | Testdateneingabe IS | 20040326 |
Method TEST_MESSAGE on class CL_XMS_MSG_FILTER_GRID has no exception.
Method TEST_SELECTION_POPUP Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CANCEL | Value transfer | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20050307 |
Method TEST_SELECTION_POPUP on class CL_XMS_MSG_FILTER_GRID has no exception.
History
| Last changed by/on | SAP | 20110908 |
| SAP Release Created in | 640 |