SAP ABAP Class CL_WTYI_IMRG (Buffer for Measurement Documents for Version)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
LO-WTY (Application Component) Warranty Claim Processing
⤷
ISAUTO_WTY (Package) Warranty Processing
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_WTY_EXT_BUFFERED_OBJECT | Base Class for External Buffered Object | 20030516 |
Properties
| Class | CL_WTYI_IMRG | |
| Short Description | Buffer for Measurement Documents for Version | |
| Super Class | CL_WTY_EXT_BUFFERED_OBJECT | Base Class for External Buffered Object |
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | ISAUTO_WTY | Warranty Processing |
| Created | 20030516 | SAP |
| Last change | 20130531 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_WTYI_IMRG has no interface implemented.
Friends
| # | Friend | Modeled only | Created on | Description |
|---|---|---|---|---|
| 1 | CL_WTY_CLONE_ASSISTANT | 20030516 | Service Class for Cloning |
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Public | Type reference (TYPE) | SEOCLSNAME | 'CL_WTYI_IMRG' | Object Type Name | 20030516 | ||
| 2 | Static Attribute | Public | Object reference (TYPE REF TO) | CL_WTY_EXT_BUFFERED_CLASS_ID | Identifies External Buffered Object | 20030516 | |||
| 3 | Static Attribute | Public | Object reference (TYPE REF TO) | CL_WTY_CLONE_ASSISTANT | Service Class for Cloning | 20030516 | |||
| 4 | Instance attribute | Public | Object reference (TYPE REF TO) | CL_WTYI_IMRG | Data Copy | 20030516 | |||
| 5 | Instance attribute | Public | Type reference (TYPE) | WTY_FLAG | Data was changed | 20030516 | |||
| 6 | Instance attribute | Private | Type reference (TYPE) | WTY_IMPT_T | WTY_IMPT Versions | 20030516 | |||
| 7 | Instance attribute | Private | Type reference (TYPE) | WTYV_IMRG_TAB | Measurement Documents for Version of Warranty Claim | 20030516 | |||
| 8 | Instance attribute | Private | Type reference (TYPE) | WTYV_IMRG_DIA_TAB | Table Type for WTYV_IMRG_DYN | 20030516 | |||
| 9 | Instance attribute | Public | Type reference (TYPE) | WTYV_IMRG_DIA_TAB | Table Type WTYV_IMRG_DIA | 20030516 | |||
| 10 | Instance attribute | Private | Type reference (TYPE) | WTY_GUID | GUID Warranty Claim | 20030516 | |||
| 11 | Instance attribute | Private | Type reference (TYPE) | WTY_MODEL | Model for Template Object | 20031124 | |||
| 12 | Instance attribute | Private | Type reference (TYPE) | WTY_RELOB | Internal Object Number | 20031124 | |||
| 13 | Instance attribute | Private | Type reference (TYPE) | WTY_RELOB_EXT | External Object Number | 20031124 | |||
| 14 | Instance attribute | Private | Type reference (TYPE) | WTY_FLAG | Read Measurement Documents? | 20030516 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 20030516 | |
| 2 | Instance method | Public | Constructor | 20030516 | ||
| 3 | Instance method | Public | Method | Copy Measurement Document When Copying Items | 20030707 | |
| 4 | Static method | Public | Method | Determine Measuring Points for Version/Items | 20030516 | |
| 5 | Static method | Private | Method | Read Measurement Documents | 20030516 | |
| 6 | Instance method | Public | Method | Read Table Buffer | 20030516 | |
| 7 | Instance method | Public | Method | Read table | 20030516 | |
| 8 | Instance method | Public | Method | Object has Changed | 20030603 | |
| 9 | Static method | Public | Method | Register Class | 20030516 | |
| 10 | Static method | Private | Method | 20030516 | ||
| 11 | Instance method | Public | Method | Change of Measuring Points for Version | 20030516 | |
| 12 | Instance method | Public | Method | First Backup after Reading of Database | 20030516 | |
| 13 | Instance method | Public | Method | Change Measurement Documents for Item | 20030516 | |
| 14 | Instance method | Public | Method | New Measurement Document Data | 20030516 |
Events
Class CL_WTYI_IMRG has no event.
Types
Class CL_WTYI_IMRG has no local type.
Method Signatures
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_WTYI_IMRG has no parameter.
Method CLASS_CONSTRUCTOR on class CL_WTYI_IMRG has no exception.
Method CONSTRUCTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_WITH_MEASUREMENT | Call by reference | Type reference (TYPE) | FLAG | SPACE | allgemeines flag | 20030516 |
Method CONSTRUCTOR on class CL_WTYI_IMRG has no exception.
Method COPY_ITEM Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_PVWTY_DIA | Call by reference | Type reference (TYPE) | WTY_PVWTY_DIA | Dialogstruktur Garantieantrag Position | 20030707 | |||
| 2 | IV_MDOCM | Call by reference | Type reference (TYPE) | WTY_MDOCM | Messbelegnummer | 20030707 |
Method COPY_ITEM on class CL_WTYI_IMRG has no exception.
Method DB_READ_MPOINTS_ITEM Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_MEAS_POINTS | Call by reference | Type reference (TYPE) | WTY_IMPT_T | Tabellentype zu WTY_IMRG_S | 20030516 | |||
| 2 | EV_MODEL | Call by reference | Type reference (TYPE) | WTY_MODEL | Modell für Musterobjekt | 20031124 | |||
| 3 | IS_PNWTYH_DIA | Call by reference | Type reference (TYPE) | WTY_PNWTYH_DIA | Dialogstruktur Garantieantrag Kopf | 20030516 | |||
| 4 | IS_PVWTY_DIA | Call by reference | Type reference (TYPE) | WTY_PVWTY_DIA | Dialogstruktur Garantieantrag Position | 20030516 |
Method DB_READ_MPOINTS_ITEM on class CL_WTYI_IMRG has no exception.
Method DB_READ_M_DOC_ITEM Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_IMRG_DIA | Call by reference | Type reference (TYPE) | WTYV_IMRG_DIA_TAB | Meßbeleg | 20030516 | |||
| 2 | ET_MEAS_POINTS | Call by reference | Type reference (TYPE) | WTY_IMPT_T | Tabellentype zu WTY_IMRG_S | 20030602 | |||
| 3 | ET_WTYI_IMRG | Call by reference | Type reference (TYPE) | WTYV_IMRG_TAB | Tabellentyp zu WTYV_IMRG | 20030516 | |||
| 4 | IS_PVWTY_DIA | Call by reference | Type reference (TYPE) | WTY_PVWTY_DIA | Dialogstruktur Garantieantrag Kopf | 20030516 | |||
| 5 | IV_DATE | Call by reference | Type reference (TYPE) | WTY_CHECK_DATE | Datum, zu dem die Belege gelesen werden | 20030516 |
Method DB_READ_M_DOC_ITEM on class CL_WTYI_IMRG has no exception.
Method GET_WTYI_IMRG Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_WTYI_IMRG | Call by reference | Type reference (TYPE) | WTYV_IMRG_TAB | Tabellentyp zu WTYV_IMRG | 20030516 | |||
| 2 | ET_WTYI_IMRG_DIA | Call by reference | Type reference (TYPE) | WTYV_IMRG_DIA_TAB | Tab.type WTYV_IMRG_DIA | 20030516 |
Method GET_WTYI_IMRG on class CL_WTYI_IMRG has no exception.
Method GET_WTYI_MPOINTS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_MPOINTS | Call by reference | Type reference (TYPE) | WTY_IMPT_T | 20030516 |
Method GET_WTYI_MPOINTS on class CL_WTYI_IMRG has no exception.
Method OBJECT_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_PNWTYH_DIA | Call by reference | Type reference (TYPE) | WTY_PNWTYH_DIA | Dialogstruktur Garantieantrag Kopf | 20030603 | |||
| 2 | IS_PNWTYV_DIA | Call by reference | Type reference (TYPE) | WTY_PNWTYV_DIA | Dialogstruktur Garantieantrag Version | 20030603 | |||
| 3 | IS_PVWTY_DIA | Call by reference | Type reference (TYPE) | WTY_PVWTY_DIA | Dialogstruktur Garantieantrag Position | 20030603 |
Method OBJECT_CHANGE on class CL_WTYI_IMRG has no exception.
Method REGISTER_IN_BUFFER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | RO_CLASS_ID | Value transfer | Object reference (TYPE REF TO) | CL_WTY_EXT_BUFFERED_CLASS_ID | Identifies external buffered object | 20030516 |
Method REGISTER_IN_BUFFER on class CL_WTYI_IMRG has no exception.
Method SET_CLASS_ID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IO_CLASS_ID | Call by reference | Object reference (TYPE REF TO) | CL_WTY_EXT_BUFFERED_CLASS_ID | Identifies external buffered object | 20030516 |
Method SET_CLASS_ID on class CL_WTYI_IMRG has no exception.
Method SET_WTYI_IMPT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_IMPT_DIA | Call by reference | Type reference (TYPE) | WTY_IMPT_T | Messpunkttabelle | 20030516 |
Method SET_WTYI_IMPT on class CL_WTYI_IMRG has no exception.
Method WTYI_FIRST_CLONE Signature
Method WTYI_FIRST_CLONE on class CL_WTYI_IMRG has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler bei der Änderung des Puffers | 20030516 |
Method WTYI_IMRG_MAINTAIN Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_PNWTYH_DIA | Call by reference | Type reference (TYPE) | WTY_PNWTYH_DIA | Dialogstruktur Garantieantrag Kopf | 20030516 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler bei der Änderung des Puffers | 20030516 |
Method WTYI_NEW_MAINTAIN Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_PNWTYH_DIA | Call by reference | Type reference (TYPE) | WTY_PNWTYH_DIA | Dialogstruktur Garantieantrag Kopf | 20030516 | |||
| 2 | IT_IMRG_DIA | Call by reference | Type reference (TYPE) | WTYV_IMRG_DIA_TAB | TABELLENTYPE ZU WTY_RIFLTCOUN | 20030516 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler bei der Änderung des Puffers | 20030516 |
History
| Last changed by/on | SAP | 20130531 |
| SAP Release Created in | 200 |