Hierarchy
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | /PLMB/IF_SPI_APPL_ACCESS | Application Access Interface | 20100810 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_WCM_SP | WCM: Service Provider Interface | 20100929 |
Properties
| Class | CL_WCM_SP_WP | |
| Short Description | WCM: Service Provider Work Permit | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | WCM | WCM: Work Clearance Management |
| Created | 20100810 | SAP |
| Last change | 20130531 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | /PLMB/IF_SPI_APPL_ACCESS | Application Access Interface | 20100810 | ||
| 2 | IF_WCM_SP | WCM: Service Provider Interface | 20100929 |
Friends
Class CL_WCM_SP_WP has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Private | See coding | 20130211 | |||||
| 2 | Instance attribute | Private | Object reference (TYPE REF TO) | CL_EAMS_BO_ORDER | Business Layer Implementation for Order | 20110215 | |||
| 3 | Instance attribute | Private | Object reference (TYPE REF TO) | IF_WCM_BL | Business Layer Implementation for WCM Object | 20100810 | |||
| 4 | Instance attribute | Private | Object reference (TYPE REF TO) | CL_EAMS_BO_SRV | EAMS BO Tools | 20101117 | |||
| 5 | Instance attribute | Private | Object reference (TYPE REF TO) | /PLMB/IF_SPI_COLLECTOR | UI Collector | 20100909 | |||
| 6 | Instance attribute | Private | Object reference (TYPE REF TO) | CL_EAMS_SP_SRV | EAMS SP Tools | 20100909 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Private | Method | Determine Mode (BO Layer) of a WCM Object | 20110202 | |
| 2 | Instance method | Public | Constructor | Constructor | 20100810 | |
| 3 | Instance method | Private | Method | Activity for Closing WCM Objects | 20101130 | |
| 4 | Instance method | Private | Method | Determine Non-Performable Activities for WCM Objects | 20101207 | |
| 5 | Instance method | Private | Method | Activity for Extending the Validity of WCM Objects | 20101130 | |
| 6 | Instance method | Private | Method | Activity for Preparing WCM Objects | 20101130 | |
| 7 | Instance method | Private | Method | Activity for Revoking Preparation of WCM Objects | 20101209 | |
| 8 | Instance method | Private | Method | Activity for Printing Work Permit of WCM Objects | 20101207 | |
| 9 | Instance method | Private | Method | Activity for Rejecting WCM Objects | 20110209 | |
| 10 | Instance method | Private | Method | Insert Header Data of WCM Objects | 20101028 | |
| 11 | Instance method | Private | Method | Inbound Mapping of WCM Object Header Data | 20110126 | |
| 12 | Instance method | Private | Method | Outbound Mapping of WCM Object Header Data | 20110126 | |
| 13 | Instance method | Private | Method | Read Header Data of WCM Objects | 20100826 | |
| 14 | Instance method | Private | Method | Change Header Data of WCM Objects | 20101021 | |
| 15 | Instance method | Private | Method | Determine Attributes for Header Data of WCM Objects | 20101207 | |
| 16 | Instance method | Private | Method | Create Messages from Check Results | 20110324 | |
| 17 | Instance method | Private | Method | Transfer of Inbound Messages to UI Collector | 20110126 | |
| 18 | Instance method | Private | Method | Transfer of Outbound Messages to UI Collector | 20110126 | |
| 19 | Instance method | Private | Method | Insert Requirements of WCM Objects | 20101125 | |
| 20 | Instance method | Private | Method | Inbound Mapping of Requirements of WCM Objects | 20110126 | |
| 21 | Instance method | Private | Method | Outbound Mapping of Requirements of WCM Objects | 20110126 | |
| 22 | Instance method | Private | Method | Read Requirements for WCM Objects | 20100910 | |
| 23 | Instance method | Private | Method | Change Requirements of WCM Objects | 20101021 | |
| 24 | Instance method | Private | Method | Determine Attributes of Requirements of WCM Objects | 20101202 | |
| 25 | Instance method | Private | Method | Create Attribute of Requirement | 20110113 | |
| 26 | Instance method | Private | Method | Determine Editability of the Data of a Node Instance | 20110103 | |
| 27 | Instance method | Private | Method | Assign to Order | 20110216 | |
| 28 | Instance method | Private | Method | Activity for Deleting Approval Assignments | 20110302 | |
| 29 | Instance method | Private | Method | Determine Non-Performable Activities for Approvals | 20110319 | |
| 30 | Instance method | Private | Method | Activity for Issuing Assigned Approvals | 20110302 | |
| 31 | Instance method | Private | Method | Activity for Revoking Issued Approvals | 20110302 | |
| 32 | Instance method | Private | Method | Assign Approvals to a WCM Object | 20110323 | |
| 33 | Instance method | Private | Method | Inbound Mapping of Approval Assignments | 20110323 | |
| 34 | Instance method | Private | Method | Outbound Mapping of Approval Assignments | 20110315 | |
| 35 | Instance method | Private | Method | Read Approval Assignments of WCM Objects | 20110315 | |
| 36 | Instance method | Private | Method | Change Approval Assignments of WCM Objects | 20110407 | |
| 37 | Instance method | Private | Method | Determine Attributes for Approval Assignments | 20110317 | |
| 38 | Instance method | Private | Method | Save All Processed WCM Objects | 20131025 | |
| 39 | Instance method | Private | Method | Transaction for Closing WCM Objects | 20101202 | |
| 40 | Instance method | Private | Method | Determine Non-Performable Transactions for WCM Objects | 20101207 | |
| 41 | Instance method | Private | Method | Transaction for Extending the Validity of WCM Objects | 20101130 | |
| 42 | Instance method | Private | Method | Transaction for Preparing WCM Objects | 20101130 | |
| 43 | Instance method | Private | Method | Transaction for Printing the Work Permit of WCM Objects | 20101207 | |
| 44 | Instance method | Private | Method | Insert Work of WCM Objects | 20101125 | |
| 45 | Instance method | Private | Method | Inbound Mapping of Work of WCM Objects | 20110126 | |
| 46 | Instance method | Private | Method | Outbound Mapping of Work of WCM Objects | 20110126 | |
| 47 | Instance method | Private | Method | Read Work for WCM Objects | 20100910 | |
| 48 | Instance method | Private | Method | Change Work of WCM Objects | 20101021 | |
| 49 | Instance method | Private | Method | Determine Attributes of Work of WCM Objects | 20101202 | |
| 50 | Instance method | Private | Method | Create Attribute of Work | 20110113 |
Events
Class CL_WCM_SP_WP has no event.
Types
| # | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
|---|---|---|---|---|---|---|---|
| 1 | TV_EDITABILITY_MODE | Protected | Type reference (TYPE) | CHAR1 | Check Mode Editability | 20130211 | |
Method Signatures
Method BO_MODE_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_EDITABLE | Value transfer | Type reference (TYPE) | WCEEDITABLE | Editierbarkeit | 20110202 | |||
| 2 | IV_LOCKERRFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Sperrfehler | 20110202 | |||
| 3 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekt sperren | 20110202 | |||
| 4 | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Statusobjektnummer | 20110202 | |||
| 5 | RV_BO_MODE | Value transfer | Type reference (TYPE) | /PLMB/SPI_MODE | Modus für BO-Layer (I/C/D) | 20110202 |
Method BO_MODE_GET on class CL_WCM_SP_WP has no exception.
Method CONSTRUCTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IO_COLLECTOR | Call by reference | Object reference (TYPE REF TO) | /PLMB/IF_SPI_COLLECTOR | UI-Kollektor | 20100908 |
Method CONSTRUCTOR on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_CLOSE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110204 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110204 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Abzuschließende FS-Dokumente (Objektschlüssel) | 20101130 |
Method HEADER_ACTION_CLOSE on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_EXCLUDED_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_ACTION_EXCLUDE | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_ACTION_NAME | Nicht ausführbare Aktionen (für keines der FS-Dokumente) | 20101207 | |||
| 2 | IS_PARAM | Value transfer | Type reference (TYPE) | WCS_SP_WP_ACTION_EXCLUDED_GET | Aktionsparameter | 20110204 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu betrachtende FS-Dokumente (Objektschlüssel) | 20101207 |
Method HEADER_ACTION_EXCLUDED_GET on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_EXTEND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110207 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110207 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu verlängernde FS-Dokumente (Objektschlüssel) | 20101130 |
Method HEADER_ACTION_EXTEND on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_PREPARE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110204 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110204 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Vorzubereitende FS-Dokumente (Objektschlüssel) | 20101130 |
Method HEADER_ACTION_PREPARE on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_PREPARE_RESET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110204 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110204 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Vorzubereitende FS-Dokumente (Objektschlüssel) | 20101209 |
Method HEADER_ACTION_PREPARE_RESET on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_PRINT_PTW Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110204 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110204 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu druckende FS-Dokumente (Objektschlüssel) | 20101207 |
Method HEADER_ACTION_PRINT_PTW on class CL_WCM_SP_WP has no exception.
Method HEADER_ACTION_REJECT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110209 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110209 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Abzuschließende FS-Dokumente (Objektschlüssel) | 20110209 |
Method HEADER_ACTION_REJECT on class CL_WCM_SP_WP has no exception.
Method HEADER_NODE_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Kopfdaten | 20110126 | |||
| 2 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Eingefügte Kopfdaten (SP-Knoten) | 20101101 | |||
| 3 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110126 | |||
| 4 | IS_PARAM | Value transfer | Type reference (TYPE) | WCS_SP_WP_PARAM_HEADER | Parameter für einzufügende Kopfdaten | 20110203 | |||
| 5 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Einzufügende Kopfdaten (SP-Knoten) | 20101028 |
Method HEADER_NODE_INSERT on class CL_WCM_SP_WP has no exception.
Method HEADER_NODE_MAP_INBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_HEADER | Value transfer | Type reference (TYPE) | WCTP1_WCAAPTAB_TYPE | Kopfdaten (BL-Knoten) | 20110126 | |||
| 2 | ET_LONGTEXT | Value transfer | Type reference (TYPE) | WCTP1_TLINESTAB_TYPE | Langtexte (BL-Knoten) | 20110126 | |||
| 3 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Kopfdaten (SP-Knoten) | 20110126 |
Method HEADER_NODE_MAP_INBOUND on class CL_WCM_SP_WP has no exception.
Method HEADER_NODE_MAP_OUTBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_LOCK_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGTAB_TYPE | Ergebnisse der Sperranforderung (BL-Knoten) | 20110204 | |||
| 2 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Kopfdaten (SP-Knoten) | 20110126 | |||
| 3 | IT_HEADER | Value transfer | Type reference (TYPE) | WCTP1_WCAAPTAB_TYPE | Kopfdaten (BL-Knoten) | 20110126 | |||
| 4 | IT_LONGTEXT | Value transfer | Type reference (TYPE) | WCTP1_TLINESTAB_TYPE | Langtexte (BL-Knoten) | 20110126 | |||
| 5 | IV_INITFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Initialer SP-Knoten | 20130129 |
Method HEADER_NODE_MAP_OUTBOUND on class CL_WCM_SP_WP has no exception.
Method HEADER_NODE_RETRIEVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_RTR_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Kopfdaten | 20110126 | |||
| 2 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Gelesene Kopfdaten (SP-Knoten) | 20100826 | |||
| 3 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110126 | |||
| 4 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu lesende Kopfdaten (Objektschlüssel) | 20100826 | |||
| 5 | IV_INITFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Initialer SP-Knoten | 20130129 | |||
| 6 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110124 |
Method HEADER_NODE_RETRIEVE on class CL_WCM_SP_WP has no exception.
Method HEADER_NODE_UPDATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Kopfdaten | 20110126 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110126 | |||
| 3 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Zu ändernde Kopfdaten (SP-Knoten) | 20101021 |
Method HEADER_NODE_UPDATE on class CL_WCM_SP_WP has no exception.
Method HEADER_PROPERTIES_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD_PROPERTIES | Value transfer | Type reference (TYPE) | EAMS_T_SP_FLDPROPERTIES | Feldeigenschaften (knoteninstanzabhängig) | 20101207 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_HEADER | Kopfdaten (SP-Knoten) | 20101207 | |||
| 3 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110202 |
Method HEADER_PROPERTIES_GET on class CL_WCM_SP_WP has no exception.
Method MESSAGES_CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_SPI_MSG | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_MSG | SPI-Nachrichten | 20110324 | |||
| 2 | IT_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGTAB_TYPE | Prüfungsergebnisse | 20110324 |
Method MESSAGES_CREATE on class CL_WCM_SP_WP has no exception.
Method MESSAGES_TRANSFER_INBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Daten | 20110126 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110126 | |||
| 3 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | INDEX TABLE | Daten (oder Schlüssel) des SP-Knotens | 20110126 | |||
| 4 | IT_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGTAB_TYPE | Ergebnisse der Datenprüfungen | 20110126 | |||
| 5 | IV_NODE_NAME | Value transfer | Type reference (TYPE) | /PLMB/SPI_NODE_NAME | Name des SP-Knotens | 20110126 | |||
| 6 | IV_TRANSFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | WCTP1_MARKED | Kennzeichen: Nachrichtenübertragung an UI-Kollektor | 20110324 |
Method MESSAGES_TRANSFER_INBOUND on class CL_WCM_SP_WP has no exception.
Method MESSAGES_TRANSFER_OUTBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_RTR_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Daten | 20110126 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110126 | |||
| 3 | IT_LOCK_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGTAB_TYPE | Ergebnisse der Sperranforderung | 20110126 | |||
| 4 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | INDEX TABLE | Daten (oder Schlüssel) des SP-Knotens | 20110126 | |||
| 5 | IT_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGTAB_TYPE | Ergebnisse der Datenprüfungen | 20110126 | |||
| 6 | IV_NODE_NAME | Value transfer | Type reference (TYPE) | /PLMB/SPI_NODE_NAME | Name des SP-Knotens | 20110126 | |||
| 7 | IV_TRANSFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | WCTP1_MARKED | Kennzeichen: Nachrichtenübertragung an UI-Kollektor | 20110324 |
Method MESSAGES_TRANSFER_OUTBOUND on class CL_WCM_SP_WP has no exception.
Method NEED_NODE_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_NODE_ID | Value transfer | Type reference (TYPE) | WCS_SP_WCMOBJ_OBJNR | Zugehörige Kopfdaten (Statusobjektnummer) | 20101125 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Einzufügende Erfordernisse (SP-Knoten) | 20101125 |
Method NEED_NODE_INSERT on class CL_WCM_SP_WP has no exception.
Method NEED_NODE_MAP_INBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_WKNEED | Value transfer | Type reference (TYPE) | WCTP1_WCA2TAB_TYPE | Arbeiten/Erfordernisse (BL-Knoten) | 20110126 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Erfordernisse (SP-Knoten) | 20110126 |
Method NEED_NODE_MAP_INBOUND on class CL_WCM_SP_WP has no exception.
Method NEED_NODE_MAP_OUTBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Erfordernisse (SP-Knoten) | 20110126 | |||
| 2 | IT_WKNEED | Value transfer | Type reference (TYPE) | WCTP1_WCA2TAB_TYPE | Arbeiten/Erfordernisse (BL-Knoten) | 20110126 |
Method NEED_NODE_MAP_OUTBOUND on class CL_WCM_SP_WP has no exception.
Method NEED_NODE_RETRIEVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Gelesene Erfordernisse (SP-Knoten) | 20100910 | |||
| 2 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Zu lesende Erfordernisse (Statusobjektnummern) | 20100910 | |||
| 3 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110202 |
Method NEED_NODE_RETRIEVE on class CL_WCM_SP_WP has no exception.
Method NEED_NODE_UPDATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Zu ändernde Erfordernisse (SP-Knoten) | 20101021 |
Method NEED_NODE_UPDATE on class CL_WCM_SP_WP has no exception.
Method NEED_PROPERTIES_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD_PROPERTIES | Value transfer | Type reference (TYPE) | EAMS_T_SP_FLDPROPERTIES | Feldeigenschaften (knoteninstanzabhängig) | 20101202 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_NEED | Erfordernisse (SP-Knoten) | 20101208 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Erfordernisse (Statusobjektnummern) | 20101208 | |||
| 4 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110202 |
Method NEED_PROPERTIES_GET on class CL_WCM_SP_WP has no exception.
Method NEED_PROPERTY_CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_BO_MODE | Value transfer | Type reference (TYPE) | /PLMB/SPI_MODE | Modus für BO-Layer (I/C/D) | 20110202 | |||
| 2 | IV_NODE_FIELD | Value transfer | Type reference (TYPE) | FIELDNAME | Feldname | 20110113 | |||
| 3 | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Statusobjektnummer | 20110113 | |||
| 4 | RS_FIELD_PROFILE | Value transfer | Type reference (TYPE) | /PLMB/S_SPI_PRPTY_PROFILE | Feldeigenschaft | 20110113 |
Method NEED_PROPERTY_CREATE on class CL_WCM_SP_WP has no exception.
Method OBJNR_EDITABILITY_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_MODE | Value transfer | Type reference (TYPE) | TV_EDITABILITY_MODE | Prüfmodus Editierbarkeit | 20130211 | |||
| 2 | IV_NODE_NAME | Value transfer | Type reference (TYPE) | /PLMB/SPI_NODE_NAME | Name des SP-Knotens | 20110103 | |||
| 3 | IV_OBJKEY | Value transfer | Type reference (TYPE) | WCTP1_OBJKEY_TYPE | Objektschlüssel | 20131025 | |||
| 4 | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Statusobjektnummer | 20110103 | |||
| 5 | RV_EDITABLE | Value transfer | Type reference (TYPE) | WCEEDITABLE | Editierbarkeit | 20110103 |
Method OBJNR_EDITABILITY_GET on class CL_WCM_SP_WP has no exception.
Method ORDER_ASSIGN Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ES_RESULT | Value transfer | Type reference (TYPE) | WCTP1_MSGLOGWA_TYPE | Ergebnis der Zuordnungsprüfungen | 20110216 | |||
| 2 | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | FS-Dokument (Statusobjektnummer) | 20110216 | |||
| 3 | IV_ORDOBJ | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Zuzuordnender Auftrag (Statusobjektnummer) | 20110216 |
Method ORDER_ASSIGN on class CL_WCM_SP_WP has no exception.
Method PERMIT_ACTION_DELETE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110302 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110302 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR_PMSOG | Genehmigungszuordnungen (zur Statusobjektnummer) | 20110302 |
Method PERMIT_ACTION_DELETE on class CL_WCM_SP_WP has no exception.
Method PERMIT_ACTION_EXCLUDED_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_ACTION_EXCLUDE | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_ACTION_NAME | Nicht ausführbare Aktionen (für keines der FS-Dokumente) | 20110319 | |||
| 2 | IS_PARAM | Value transfer | Type reference (TYPE) | WCS_SP_WP_ACTION_EXCLUDED_GET | Aktionsparameter | 20110319 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR_PMSOG | Zu betrachtende Genehmigungen (zur Statusobjektnummer) | 20110319 |
Method PERMIT_ACTION_EXCLUDED_GET on class CL_WCM_SP_WP has no exception.
Method PERMIT_ACTION_ISSUE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110302 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110302 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR_PMSOG | Genehmigungszuordnungen (zur Statusobjektnummer) | 20110302 |
Method PERMIT_ACTION_ISSUE on class CL_WCM_SP_WP has no exception.
Method PERMIT_ACTION_REVOKE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110302 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110302 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR_PMSOG | Genehmigungszuordnungen (zur Statusobjektnummer) | 20110302 |
Method PERMIT_ACTION_REVOKE on class CL_WCM_SP_WP has no exception.
Method PERMIT_NODE_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110329 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110329 | |||
| 3 | IS_NODE_ID | Value transfer | Type reference (TYPE) | WCS_SP_WCMOBJ_OBJNR | Zugehörige Kopfdaten (Statusobjektnummer) | 20110323 | |||
| 4 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Zuzuordnende Genehmigungen (SP-Knoten) | 20110323 |
Method PERMIT_NODE_INSERT on class CL_WCM_SP_WP has no exception.
Method PERMIT_NODE_MAP_INBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_PERMIT | Value transfer | Type reference (TYPE) | WCTP1_PERMITTAB_TYPE | Genehmigungszuordnungen (BL-Knoten) | 20110406 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Genehmigungszuordnungen (SP-Knoten) | 20110323 |
Method PERMIT_NODE_MAP_INBOUND on class CL_WCM_SP_WP has no exception.
Method PERMIT_NODE_MAP_OUTBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Genehmigungszuordnungen (SP-Knoten) | 20110315 | |||
| 2 | IT_PERMIT | Value transfer | Type reference (TYPE) | WCTP1_PERMITTAB_TYPE | Genehmigungszuordnungen (BL-Knoten) | 20110406 |
Method PERMIT_NODE_MAP_OUTBOUND on class CL_WCM_SP_WP has no exception.
Method PERMIT_NODE_RETRIEVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Gelesene Genehmigungszuordnungen (SP-Knoten) | 20110315 | |||
| 2 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Zu lesende Genehmigungszuordnungen (Statusobjektnummern) | 20110315 | |||
| 3 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110315 |
Method PERMIT_NODE_RETRIEVE on class CL_WCM_SP_WP has no exception.
Method PERMIT_NODE_UPDATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten Kopfdaten | 20110407 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110407 | |||
| 3 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Zu ändernde Genehmigungszuordnungen (SP-Knoten) | 20110407 |
Method PERMIT_NODE_UPDATE on class CL_WCM_SP_WP has no exception.
Method PERMIT_PROPERTIES_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD_PROPERTIES | Value transfer | Type reference (TYPE) | EAMS_T_SP_FLDPROPERTIES | Feldeigenschaften (knoteninstanzabhängig) | 20110317 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_PERMIT | Genehmigungszuordnungen (SP-Knoten) | 20110317 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Genehmigungszuordnungen (Statusobjektnummern) | 20110317 | |||
| 4 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110317 |
Method PERMIT_PROPERTIES_GET on class CL_WCM_SP_WP has no exception.
Method SAVE_ALL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20131025 |
Method SAVE_ALL on class CL_WCM_SP_WP has no exception.
Method TRANSACTION_CLOSE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110207 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110207 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Abzuschließende FS-Dokumente (Objektschlüssel) | 20101202 |
Method TRANSACTION_CLOSE on class CL_WCM_SP_WP has no exception.
Method TRANSACTION_EXCLUDED_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_ACTION_EXCLUDE | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_ACTION_NAME | Nicht ausführbare Aktionen (für keines der FS-Dokumente) | 20101207 | |||
| 2 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu betrachtende FS-Dokumente (Objektschlüssel) | 20101207 |
Method TRANSACTION_EXCLUDED_GET on class CL_WCM_SP_WP has no exception.
Method TRANSACTION_EXTEND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110207 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110207 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu verlängernde FS-Dokumente (Objektschlüssel) | 20101130 |
Method TRANSACTION_EXTEND on class CL_WCM_SP_WP has no exception.
Method TRANSACTION_PREPARE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110207 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110207 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Vorzubereitende FS-Dokumente (Objektschlüssel) | 20101130 |
Method TRANSACTION_PREPARE on class CL_WCM_SP_WP has no exception.
Method TRANSACTION_PRINT_PTW Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_INDEX_FAILED | Value transfer | Type reference (TYPE) | /PLMB/T_SPI_INDEX_FAILED | Indizes der fehlerhaft verarbeiteten FS-Dokumente | 20110207 | |||
| 2 | EV_FAILED | Value transfer | Type reference (TYPE) | /PLMB/SPI_FAILED_IND | Kennzeichen: Fehlerhafte Verarbeitung | 20110207 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WAPI_INSTANCE | Zu druckende FS-Dokumente (Objektschlüssel) | 20101207 |
Method TRANSACTION_PRINT_PTW on class CL_WCM_SP_WP has no exception.
Method WORK_NODE_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_NODE_ID | Value transfer | Type reference (TYPE) | WCS_SP_WCMOBJ_OBJNR | Zugehörige Kopfdaten (Statusobjektnummer) | 20101125 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Einzufügende Arbeiten (SP-Knoten) | 20101125 |
Method WORK_NODE_INSERT on class CL_WCM_SP_WP has no exception.
Method WORK_NODE_MAP_INBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_WKNEED | Value transfer | Type reference (TYPE) | WCTP1_WCA2TAB_TYPE | Arbeiten/Erfordernisse (BL-Knoten) | 20110126 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Arbeiten (SP-Knoten) | 20110126 |
Method WORK_NODE_MAP_INBOUND on class CL_WCM_SP_WP has no exception.
Method WORK_NODE_MAP_OUTBOUND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Arbeiten (SP-Knoten) | 20110126 | |||
| 2 | IT_WKNEED | Value transfer | Type reference (TYPE) | WCTP1_WCA2TAB_TYPE | Arbeiten/Erfordernisse (BL-Knoten) | 20110126 |
Method WORK_NODE_MAP_OUTBOUND on class CL_WCM_SP_WP has no exception.
Method WORK_NODE_RETRIEVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Gelesene Arbeiten (SP-Knoten) | 20100910 | |||
| 2 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Zu lesende Arbeiten (Statusobjektnummern) | 20100910 | |||
| 3 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110202 |
Method WORK_NODE_RETRIEVE on class CL_WCM_SP_WP has no exception.
Method WORK_NODE_UPDATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Zu ändernde Arbeiten (SP-Knoten) | 20101021 |
Method WORK_NODE_UPDATE on class CL_WCM_SP_WP has no exception.
Method WORK_PROPERTIES_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD_PROPERTIES | Value transfer | Type reference (TYPE) | EAMS_T_SP_FLDPROPERTIES | Feldeigenschaften (knoteninstanzabhängig) | 20101202 | |||
| 2 | IT_NODE_DATA | Value transfer | Type reference (TYPE) | WCT_SP_WP_NODE_WORK | Arbeiten (SP-Knoten) | 20101208 | |||
| 3 | IT_NODE_ID | Value transfer | Type reference (TYPE) | WCT_SP_WCMOBJ_OBJNR | Arbeiten (Statusobjektnummern) | 20101208 | |||
| 4 | IV_LOCKFLG | Value transfer | Type reference (TYPE) | WCTP1_FLG_TYPE | Kennzeichen: Objekte sperren | 20110202 |
Method WORK_PROPERTIES_GET on class CL_WCM_SP_WP has no exception.
Method WORK_PROPERTY_CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_BO_MODE | Value transfer | Type reference (TYPE) | /PLMB/SPI_MODE | Modus für BO-Layer (I/C/D) | 20110202 | |||
| 2 | IV_NODE_FIELD | Value transfer | Type reference (TYPE) | FIELDNAME | Feldname | 20110113 | |||
| 3 | IV_OBJNR | Value transfer | Type reference (TYPE) | WCTP1_OBJNR_TYPE | Statusobjektnummer | 20110113 | |||
| 4 | RS_FIELD_PROFILE | Value transfer | Type reference (TYPE) | /PLMB/S_SPI_PRPTY_PROFILE | Feldeigenschaft | 20110113 |
Method WORK_PROPERTY_CREATE on class CL_WCM_SP_WP has no exception.
History
| Last changed by/on | SAP | 20130531 |
| SAP Release Created in | 606 |