SAP ABAP Class CL_SRT_WSP_TEST_SINGLE_CONFIG (Unit Test Class for Single Config Security)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-ESI-WS-ABA-RT (Application Component) WebServices ABAP Runtime
⤷
SOAP_FT_TESTS (Package) Testpaket zur Massenkonfiguration für Enterprise Services
⤷
⤷
Properties
| Class | CL_SRT_WSP_TEST_SINGLE_CONFIG | |
| Short Description | Unit Test Class for Single Config Security | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 5 | |
| Package | SOAP_FT_TESTS | Testpaket zur Massenkonfiguration für Enterprise Services |
| Created | 20130312 | SAP |
| Last change | 20140121 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class CL_SRT_WSP_TEST_SINGLE_CONFIG has no forward declaration.
Interfaces
Class CL_SRT_WSP_TEST_SINGLE_CONFIG has no interface implemented.
Friends
Class CL_SRT_WSP_TEST_SINGLE_CONFIG has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_BINDING' | 20130312 | |||
| 2 | Constant | Protected | Type reference (TYPE) | STRING | 'urn:sap:soap:subject:namespace:binding:soamanager:710' | 20130312 | |||
| 3 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_MANUAL_BASIC' | 20130312 | |||
| 4 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_MANUAL_SSO' | 20130312 | |||
| 5 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_MANUAL_X509' | 20130312 | |||
| 6 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_SR_BASIC' | 20130312 | |||
| 7 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_SR_SSO' | 20130312 | |||
| 8 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_SR_X509' | 20130312 | |||
| 9 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_WSDL_BASIC' | 20130312 | |||
| 10 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_WSDL_SSO' | 20130312 | |||
| 11 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_LP_WSDL_X509' | 20130312 | |||
| 12 | Constant | Protected | Type reference (TYPE) | STRING | 'UNITTEST_SERVICE' | 20130312 | |||
| 13 | Instance attribute | Protected | Object reference (TYPE REF TO) | CL_SRT_WSP_WD_TESTER | Webdynpro Tester Class for WS Config UIs | 20130312 | |||
| 14 | Static Attribute | Protected | Type reference (TYPE) | STRING | 20130312 | ||||
| 15 | Static Attribute | Protected | Type reference (TYPE) | STRING | 20130312 | ||||
| 16 | Static Attribute | Protected | Type reference (TYPE) | STRING | 20130312 | ||||
| 17 | Static Attribute | Protected | Type reference (TYPE) | STRING | 20130312 | ||||
| 18 | Static Attribute | Protected | Type reference (TYPE) | STRING | 20130312 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Protected | Method | 20130320 | ||
| 2 | Instance method | Protected | Method | Create Binding | 20130312 | |
| 3 | Instance method | Protected | Method | Create Log Port manually (Basic Authentication) | 20130312 | |
| 4 | Instance method | Protected | Method | Create Log Port manually (SSO2 Authentication) | 20130312 | |
| 5 | Instance method | Protected | Method | Create Log Port manually (X509 Authentication) | 20130312 | |
| 6 | Instance method | Protected | Method | Create Log Port using Services Registry (Basic Authentic.) | 20130312 | |
| 7 | Instance method | Protected | Method | Create Log Port using Services Registry (SSO2 Authentic.) | 20130312 | |
| 8 | Instance method | Protected | Method | Create Log Port using Services Registry (X509 Authentic.) | 20130312 | |
| 9 | Instance method | Protected | Method | Create Log Port by WSDL (Basic Authentic.) | 20130312 | |
| 10 | Instance method | Protected | Method | Create Log Port by WSDL (SSO2 Authentic.) | 20130312 | |
| 11 | Instance method | Protected | Method | Create Log Port by WSDL (X509 Authentic.) | 20130312 | |
| 12 | Instance method | Protected | Method | Delete created Binding | 20130312 | |
| 13 | Instance method | Protected | Method | Delete all created Log Ports | 20130312 | |
| 14 | Instance method | Protected | Method | Get information for Access URL path, host, port and protocol | 20130312 | |
| 15 | Instance method | Protected | Method | Get WSDL for created binding | 20130312 | |
| 16 | Instance method | Private | Method | Get label text for property | 20130312 | |
| 17 | Instance method | Private | Method | Get tab text for topic | 20130312 | |
| 18 | Instance method | Protected | Method | 20130320 | ||
| 19 | Instance method | Protected | Method | 20130320 | ||
| 20 | Instance method | Protected | Method | 20130320 | ||
| 21 | Instance method | Protected | Method | 20130320 | ||
| 22 | Instance method | Private | Method | Teardown (Close WD Components) | 20130312 |
Events
Class CL_SRT_WSP_TEST_SINGLE_CONFIG has no event.
Types
Class CL_SRT_WSP_TEST_SINGLE_CONFIG has no local type.
Method Signatures
Method BACK Signature
Method BACK on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method BACK on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_BINDING Signature
Method CREATE_BINDING on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_BINDING on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_MANUAL_LP_BASIC Signature
Method CREATE_MANUAL_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_MANUAL_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_MANUAL_LP_SSO Signature
Method CREATE_MANUAL_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_MANUAL_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_MANUAL_LP_X509 Signature
Method CREATE_MANUAL_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_MANUAL_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_SR_LP_BASIC Signature
Method CREATE_SR_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_SR_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_SR_LP_SSO Signature
Method CREATE_SR_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_SR_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_SR_LP_X509 Signature
Method CREATE_SR_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_SR_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_WSDL_LP_BASIC Signature
Method CREATE_WSDL_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_WSDL_LP_BASIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_WSDL_LP_SSO Signature
Method CREATE_WSDL_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_WSDL_LP_SSO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method CREATE_WSDL_LP_X509 Signature
Method CREATE_WSDL_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method CREATE_WSDL_LP_X509 on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method DELETE_BINDING Signature
Method DELETE_BINDING on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method DELETE_BINDING on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method DELETE_LOGPORT Signature
Method DELETE_LOGPORT on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method DELETE_LOGPORT on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method GET_ACCESS_URL_INFO Signature
Method GET_ACCESS_URL_INFO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method GET_ACCESS_URL_INFO on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method GET_BND_WSDL Signature
Method GET_BND_WSDL on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method GET_BND_WSDL on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method GET_LABEL_TEXT_FOR_PROPERTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_PROPERTY_NAME | Call by reference | Type reference (TYPE) | STRING | 20130312 | ||||
| 2 | I_PROPERTY_NAMESPACE | Call by reference | Type reference (TYPE) | STRING | 20130312 | ||||
| 3 | R_LABEL_TEXT | Value transfer | Type reference (TYPE) | STRING | 20130312 |
Method GET_LABEL_TEXT_FOR_PROPERTY on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method GET_TAB_TEXT_FOR_TOPIC Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_TOPIC_NAME | Call by reference | Type reference (TYPE) | STRING | 20130312 | ||||
| 2 | R_LABEL_TEXT | Value transfer | Type reference (TYPE) | STRING | 20130312 |
Method GET_TAB_TEXT_FOR_TOPIC on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method NAVIGATE_TO_CONSUMER Signature
Method NAVIGATE_TO_CONSUMER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method NAVIGATE_TO_CONSUMER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method NAVIGATE_TO_PROVIDER Signature
Method NAVIGATE_TO_PROVIDER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method NAVIGATE_TO_PROVIDER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method OPEN_SOAMANAGER Signature
Method OPEN_SOAMANAGER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method OPEN_SOAMANAGER on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method SEARCH Signature
Method SEARCH on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method SEARCH on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
Method TEARDOWN Signature
Method TEARDOWN on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no parameter.
Method TEARDOWN on class CL_SRT_WSP_TEST_SINGLE_CONFIG has no exception.
History
| Last changed by/on | SAP | 20140121 |
| SAP Release Created in | 740 |