SAP ABAP Class CL_SRT_WSP_CONSUMER_FACTORY_S (Consumer Factory Sender Determination)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-ESI-WS-ABA-CFG (Application Component) WebServices ABAP Configuration
⤷ SOAP_CONFIG (Package) SOAP Configuration Framework
⤷ BC-ESI-WS-ABA-CFG (Application Component) WebServices ABAP Configuration
⤷ SOAP_CONFIG (Package) SOAP Configuration Framework
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_SRT_WSP_CONSUMER_FACTORY_S | SRT: Consumer Factory Configuration | 20120615 |
Properties
Class | CL_SRT_WSP_CONSUMER_FACTORY_S | |
Short Description | Consumer Factory Sender Determination | |
Super Class | ||
Instantiability of a Class | 0 | Private |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SOAP_CONFIG | SOAP Configuration Framework |
Created | 20120615 | SAP |
Last change | 20131127 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_SRT_WSP_CONSUMER_FACTORY_S has no forward declaration.
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_SRT_WSP_CONSUMER_FACTORY_S | SRT: Consumer Factory Configuration | 20120615 |
Friends
# | Friend | Modeled only | Created on | Description |
---|---|---|---|---|
1 | CL_SRT_WSP_CONSUMER_FACTORY | 20120615 | SRT: Consumer Factory |
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | CHANGED | Instance attribute | Private | Type reference (TYPE) | BOOLEAN | 20120615 | |||
2 | CO_CLASS_NAME | Constant | Private | Type reference (TYPE) | SRT_WSP_DT_OBJ_NAME | 'CL_SRT_WSP_CONSUMER_FACTORY_S' | 20120615 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CHECK_HAS_CHANGED | Instance method | Private | Method | Check whether Expressions and Select-Options have changed | 20120615 |
2 | CHECK_PRIORITY | Instance method | Private | Method | Check Priority | 20120615 |
3 | CONSTRUCTOR | Instance method | Public | Constructor | CONSTRUCTOR | 20120615 |
4 | HAS_CHANGED | Instance method | Private | Method | Set Changed | 20120615 |
5 | INIT_DT_OBJECT | Instance method | Private | Method | 20120615 | |
6 | INIT_FROM_DB | Instance method | Private | Method | 20120615 | |
7 | OPEN | Static method | Protected | Method | 20120615 |
Events
Class CL_SRT_WSP_CONSUMER_FACTORY_S has no event.
Types
Class CL_SRT_WSP_CONSUMER_FACTORY_S has no local type.
Method Signatures
Method CHECK_HAS_CHANGED Signature
Method CHECK_HAS_CHANGED on class CL_SRT_WSP_CONSUMER_FACTORY_S has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method CHECK_PRIORITY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CONDITION_KEY | Call by reference | Type reference (TYPE) | SRT_WSP_COND_KEY | 20120615 | |||
2 | Returning | IS_VALID | Value transfer | Type reference (TYPE) | BOOLEAN | 20120615 | |||
3 | Importing | PRIORITY | Call by reference | Type reference (TYPE) | SRT_LRD_ROUTING_PRIORITY | 20120615 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CONSUMER_FACTORY | Call by reference | Object reference (TYPE REF TO) | CL_SRT_WSP_CONSUMER_FACTORY | 20120615 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method HAS_CHANGED Signature
Method HAS_CHANGED on class CL_SRT_WSP_CONSUMER_FACTORY_S has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method INIT_DT_OBJECT Signature
Method INIT_DT_OBJECT on class CL_SRT_WSP_CONSUMER_FACTORY_S has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method INIT_FROM_DB Signature
Method INIT_FROM_DB on class CL_SRT_WSP_CONSUMER_FACTORY_S has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
Method OPEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CONSUMER_FACTORY | Call by reference | Object reference (TYPE REF TO) | CL_SRT_WSP_CONSUMER_FACTORY | 20120615 | |||
2 | Returning | CONSUMER_FACTORY_S | Value transfer | Object reference (TYPE REF TO) | CL_SRT_WSP_CONSUMER_FACTORY_S | 20120615 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SRT_WSP_CONFIG | 20120615 |
History
Last changed by/on | SAP | 20131127 |
SAP Release Created in | 740 |