Hierarchy
⤷
⤷
Properties
| Class | CL_SRT_TEST_UNITS | |
| Short Description | Test Units | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | SOAP_RT_TESTS | ABAP Unit Test Cases for ABAP SOAP Runtime |
| Created | 20060929 | SAP |
| Last change | 20090618 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class CL_SRT_TEST_UNITS has no forward declaration.
Interfaces
Class CL_SRT_TEST_UNITS has no interface implemented.
Friends
Class CL_SRT_TEST_UNITS has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Private | Type reference (TYPE) | CHAR1 | '|' | Separator for Action Field | 20070301 | ||
| 2 | Constant | Public | Type reference (TYPE) | I | 1 | 20070301 | |||
| 3 | Constant | Public | Type reference (TYPE) | I | 1000000 | 20070301 | |||
| 4 | Constant | Public | Type reference (TYPE) | I | 1024 | 20070301 | |||
| 5 | Constant | Public | Type reference (TYPE) | I | 512 | 20070301 | |||
| 6 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP1_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 7 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP2_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 8 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP3_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 9 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP4_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 10 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP5_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 11 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP6_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 12 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP7_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 13 | Static Attribute | Public | Type reference (TYPE) | SRT_TEST_OP8_REQUEST | Proxy Structure (Generated) | 20070126 | |||
| 14 | Static Attribute | Public | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Client Sequence for Sequence Processing of Web Services | 20070126 | |||
| 15 | Static Attribute | Public | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Class (Generated) | 20070126 | |||
| 16 | Static Attribute | Public | Object reference (TYPE REF TO) | IF_WSPROTOCOL | ABAP Proxies: Available Protocols | 20070126 |
Methods
Events
Class CL_SRT_TEST_UNITS has no event.
Types
Class CL_SRT_TEST_UNITS has no local type.
Method Signatures
Method CHECK_REQUEST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | REQUEST | Call by reference | Type reference (TYPE) | SRT_TEST_REQUEST | Proxy Struktur (generiert) | 20070213 | |||
| 2 | RETURN | Value transfer | Type reference (TYPE) | STRING | 20070213 |
Method CHECK_REQUEST on class CL_SRT_TEST_UNITS has no exception.
Method CREATE_OBJECT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | LP | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20060930 | |||
| 2 | SEQO | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20061106 | |||
| 3 | SEQ_PROT | Value transfer | Object reference (TYPE REF TO) | IF_WSPROTOCOL | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20060930 | |||
| 4 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20060930 |
Method CREATE_OBJECT on class CL_SRT_TEST_UNITS has no exception.
Method CREATE_P_SEQUENCES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | LP | Call by reference | Type reference (TYPE) | SRT_LP_NAME | 20061011 | ||||
| 2 | PRX_CLASS | Call by reference | Type reference (TYPE) | SRT_LP_PROXYCLASS | 20061011 |
Method CREATE_P_SEQUENCES on class CL_SRT_TEST_UNITS has no exception.
Method CREATE_P_SEQUENCE_ID_BY_TYPE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | LP | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20061011 | |||
| 2 | PRX_CLASS | Call by reference | Type reference (TYPE) | SRT_LP_PROXYCLASS | Proxyklasse eines logischen Ports | 20061011 | |||
| 3 | TYPE | Call by reference | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20061011 |
Method CREATE_P_SEQUENCE_ID_BY_TYPE on class CL_SRT_TEST_UNITS has no exception.
Method CREATE_REQUEST_WITH_OPTIONS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ACTION_TABLE | Call by reference | Type reference (TYPE) | SRT_STR_TABLE | Tabelle von Strings | 20070301 | |||
| 2 | PASSPORT_ID | Call by reference | Type reference (TYPE) | STRING | 20070301 | ||||
| 3 | REQUEST | Value transfer | Type reference (TYPE) | SRT_TEST_REQUEST | Proxy Struktur (generiert) | 20070301 | |||
| 4 | REQUEST_STRING | Call by reference | Type reference (TYPE) | STRING | 20070301 |
Method CREATE_REQUEST_WITH_OPTIONS on class CL_SRT_TEST_UNITS has no exception.
Method EXECUTE_UNITS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COUNT | Call by reference | Type reference (TYPE) | INT4 | Natürliche Zahl | 20070126 | |||
| 2 | LPORT | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070126 | |||
| 3 | MESSTAB | Call by reference | Type reference (TYPE) | SRT_MESSAGE_T | Tabelle zur Meldungsausgabe | 20070126 | |||
| 4 | SEQ1 | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20070129 | |||
| 5 | SEQ2 | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20070129 | |||
| 6 | SEQO | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20070129 | |||
| 7 | SEQ_PROT | Call by reference | Object reference (TYPE REF TO) | IF_WSPROTOCOL | ABAP Proxies: Zur Verfügung stehende Protokolle | 20070129 | |||
| 8 | STOP_ON_ERROR | Call by reference | Type reference (TYPE) | BOOLEAN | 'X' | boolsche Variable (X=true, -=false, space=unknown) | 20070126 | ||
| 9 | TESTSEQUENCE | Call by reference | Type reference (TYPE) | SRT_TST_EXE_T | Struktur der Testausführungen | 20070126 |
Method EXECUTE_UNITS on class CL_SRT_TEST_UNITS has no exception.
Method FILL_OP1 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | OP1 | Call by reference | Type reference (TYPE) | SRT_TEST_OP1_REQUEST | Proxy Struktur (generiert) | 20070301 |
Method FILL_OP1 on class CL_SRT_TEST_UNITS has no exception.
Method GET_LOAD_DATA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATA | Value transfer | Type reference (TYPE) | STRING | 20070228 | ||||
| 2 | SIZE | Call by reference | Type reference (TYPE) | I | 20070228 |
Method GET_LOAD_DATA on class CL_SRT_TEST_UNITS has no exception.
Method GET_P_SEQUENCE_ID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | LP | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20061011 | |||
| 2 | PRX_CLASS | Call by reference | Type reference (TYPE) | SRT_LP_PROXYCLASS | Proxyklasse eines logischen Ports | 20061009 | |||
| 3 | SEQID | Value transfer | Type reference (TYPE) | CHAR32 | Characterfeld der Länge 32 | 20061009 | |||
| 4 | TYPE | Call by reference | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20061009 |
Method GET_P_SEQUENCE_ID on class CL_SRT_TEST_UNITS has no exception.
Method OP1 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP1 | Call by reference | Type reference (TYPE) | SRT_TEST_OP1_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP1 on class CL_SRT_TEST_UNITS has no exception.
Method OP2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP2 | Call by reference | Type reference (TYPE) | SRT_TEST_OP2_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP2 on class CL_SRT_TEST_UNITS has no exception.
Method OP3 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP3 | Call by reference | Type reference (TYPE) | SRT_TEST_OP3_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP3 on class CL_SRT_TEST_UNITS has no exception.
Method OP4 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP4 | Call by reference | Type reference (TYPE) | SRT_TEST_OP4_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP4 on class CL_SRT_TEST_UNITS has no exception.
Method OP5 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP5 | Call by reference | Type reference (TYPE) | SRT_TEST_OP5_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP5 on class CL_SRT_TEST_UNITS has no exception.
Method OP6 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP6 | Call by reference | Type reference (TYPE) | SRT_TEST_OP6_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP6 on class CL_SRT_TEST_UNITS has no exception.
Method OP7 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP7 | Call by reference | Type reference (TYPE) | SRT_TEST_OP7_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP7 on class CL_SRT_TEST_UNITS has no exception.
Method OP8 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | NUMBER | Call by reference | Type reference (TYPE) | I | 20061002 | ||||
| 2 | OP8 | Call by reference | Type reference (TYPE) | SRT_TEST_OP8_REQUEST | Proxy Struktur (generiert) | 20060930 | |||
| 3 | SEQ | Call by reference | Object reference (TYPE REF TO) | CO_SRT_TEST_SERVICE_OUT_710 | Proxy Klasse (generiert) | 20060930 | |||
| 4 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method OP8 on class CL_SRT_TEST_UNITS has no exception.
Method PUT_P_SEQUENCE_ID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PRX_CLASS | Call by reference | Type reference (TYPE) | SRT_LP_PROXYCLASS | Proxyklasse eines logischen Ports | 20061009 | |||
| 2 | SEQID | Call by reference | Type reference (TYPE) | CHAR32 | Characterfeld der Länge 32 | 20061009 | |||
| 3 | TYPE | Call by reference | Type reference (TYPE) | CHAR1 | Einstelliges Kennzeichen | 20061009 | |||
| 4 | VALID | Call by reference | Type reference (TYPE) | TIMESTAMPL | Aktuelles Datum des Applikationsservers | 20061009 |
Method PUT_P_SEQUENCE_ID on class CL_SRT_TEST_UNITS has no exception.
Method RUN_PERSISTENT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COUNT | Call by reference | Type reference (TYPE) | I | 20070125 | ||||
| 2 | LP | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070125 | |||
| 3 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070125 |
Method RUN_PERSISTENT on class CL_SRT_TEST_UNITS has no exception.
Method RUN_UC1 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COMMIT | Call by reference | Type reference (TYPE) | BOOLEAN | boolsche Variable (X=true, -=false, space=unknown) | 20070206 | |||
| 2 | COUNT | Call by reference | Type reference (TYPE) | I | 20070206 | ||||
| 3 | LOGISCHER_PORT | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070206 | |||
| 4 | OP1 | Call by reference | Type reference (TYPE) | SRT_TEST_OP1_REQUEST | Einstelliges Kennzeichen | 20070206 | |||
| 5 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070206 |
Method RUN_UC1 on class CL_SRT_TEST_UNITS has no exception.
Method RUN_UC10 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COMMIT | Call by reference | Type reference (TYPE) | BOOLEAN | boolsche Variable (X=true, -=false, space=unknown) | 20070309 | |||
| 2 | COUNT | Call by reference | Type reference (TYPE) | I | 20070309 | ||||
| 3 | LOGISCHER_PORT | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070309 | |||
| 4 | OP3 | Call by reference | Type reference (TYPE) | SRT_TEST_OP3_REQUEST | Proxy Struktur (generiert) | 20070309 | |||
| 5 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070309 |
Method RUN_UC10 on class CL_SRT_TEST_UNITS has no exception.
Method RUN_UC15A Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COMMIT | Call by reference | Type reference (TYPE) | BOOLEAN | boolsche Variable (X=true, -=false, space=unknown) | 20070206 | |||
| 2 | COUNT | Call by reference | Type reference (TYPE) | I | 20070206 | ||||
| 3 | LOGISCHER_PORT | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070206 | |||
| 4 | OP5 | Call by reference | Type reference (TYPE) | SRT_TEST_OP5_REQUEST | Proxy Struktur (generiert) | 20070206 | |||
| 5 | OP6 | Call by reference | Type reference (TYPE) | SRT_TEST_OP6_REQUEST | Proxy Struktur (generiert) | 20070206 | |||
| 6 | OP7 | Call by reference | Type reference (TYPE) | SRT_TEST_OP7_REQUEST | Proxy Struktur (generiert) | 20070206 | |||
| 7 | OP8 | Call by reference | Type reference (TYPE) | SRT_TEST_OP8_REQUEST | Proxy Struktur (generiert) | 20070206 | |||
| 8 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070206 |
Method RUN_UC15A on class CL_SRT_TEST_UNITS has no exception.
Method RUN_UC2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | COMMIT | Call by reference | Type reference (TYPE) | BOOLEAN | boolsche Variable (X=true, -=false, space=unknown) | 20070206 | |||
| 2 | COUNT | Call by reference | Type reference (TYPE) | I | 20070206 | ||||
| 3 | LOGISCHER_PORT | Call by reference | Type reference (TYPE) | SRT_LP_NAME | Logischer Port Name | 20070206 | |||
| 4 | OP1 | Call by reference | Type reference (TYPE) | SRT_TEST_OP1_REQUEST | Proxy Struktur (generiert) | 20070206 | |||
| 5 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070206 |
Method RUN_UC2 on class CL_SRT_TEST_UNITS has no exception.
Method SEQUENCE_BEGIN Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | SEQ | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20060930 | |||
| 2 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20060930 |
Method SEQUENCE_BEGIN on class CL_SRT_TEST_UNITS has no exception.
Method SEQUENCE_END Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | SEQ | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20060930 | |||
| 2 | TEXT | Value transfer | Type reference (TYPE) | STRING | 20060930 |
Method SEQUENCE_END on class CL_SRT_TEST_UNITS has no exception.
Method SEQUENCE_TERMINATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | SEQ | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Einstelliges Kennzeichen | 20070129 | |||
| 2 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20070129 |
Method SEQUENCE_TERMINATE on class CL_SRT_TEST_UNITS has no exception.
Method SET_CLIENT_SEQUENCE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | SEQ | Call by reference | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Einstelliges Kennzeichen | 20070130 | |||
| 2 | SEQ_PROT | Call by reference | Object reference (TYPE REF TO) | IF_WSPROTOCOL | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20070122 | |||
| 3 | TEXT | Call by reference | Type reference (TYPE) | STRING | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20070122 |
Method SET_CLIENT_SEQUENCE on class CL_SRT_TEST_UNITS has no exception.
Method SET_PERS_SEQUENCE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ID | Call by reference | Type reference (TYPE) | SRT_SEQ_ID | 20061011 | ||||
| 2 | ON_FAILURE | Call by reference | Type reference (TYPE) | BOOLEAN | ' ' | boolsche Variable (X=true, -=false, space=unknown) | 20070305 | ||
| 3 | SEQ | Value transfer | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Sequenz im Client für Reihenfolge-Verarb. von Web Services | 20060930 | |||
| 4 | SEQ_PROT | Call by reference | Object reference (TYPE REF TO) | IF_WSPROTOCOL | ABAP Proxies: Zur Verfügung stehende Protokolle | 20060930 | |||
| 5 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20060930 |
Method SET_PERS_SEQUENCE on class CL_SRT_TEST_UNITS has no exception.
Method SET_TRANS_SEQUENCE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ON_FAILURE | Call by reference | Type reference (TYPE) | BOOLEAN | ' ' | boolsche Variable (X=true, -=false, space=unknown) | 20070305 | ||
| 2 | SEQ | Value transfer | Object reference (TYPE REF TO) | IF_WS_CLIENT_SEQUENCE | Einstelliges Kennzeichen | 20060930 | |||
| 3 | SEQ_PROT | Call by reference | Object reference (TYPE REF TO) | IF_WSPROTOCOL | nur WS: Steuerung der Reihenfolge-Verarbeitung | 20060930 | |||
| 4 | TEXT | Call by reference | Type reference (TYPE) | STRING | 20060930 |
Method SET_TRANS_SEQUENCE on class CL_SRT_TEST_UNITS has no exception.
Method TERMINATE_P_SEQUENCE_ID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PRX_CLASS | Call by reference | Type reference (TYPE) | SRT_LP_PROXYCLASS | Proxyklasse eines logischen Ports | 20061009 |
Method TERMINATE_P_SEQUENCE_ID on class CL_SRT_TEST_UNITS has no exception.
Method WAIT Signature
Method WAIT on class CL_SRT_TEST_UNITS has no parameter.
Method WAIT on class CL_SRT_TEST_UNITS has no exception.
History
| Last changed by/on | SAP | 20090618 |
| SAP Release Created in | 710 |