SAP ABAP Class CL_SMT_REF_CONTAINER (Container that saves reference to input parameters)
Hierarchy
☛
SAP_BS_FND (Software Component) SAP Business Suite Foundation
⤷
CA-SOA-SMT (Application Component) Service Mapping Tool
⤷
GMT_MODEL (Package) Model Access for External Users
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_SMT_REF_CONTAINER_LIST | List of Reference Containers | 20080122 |
| 2 | Inheritance (c INHERITING FROM c_ref) | CL_SMT_REF_TO_DATA_CONTAINER | Container that saves reference with ref. to data | 20080104 |
Properties
| Class | CL_SMT_REF_CONTAINER | |
| Short Description | Container that saves reference to input parameters | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | GMT_MODEL | Model Access for External Users |
| Created | 20080104 | SAP |
| Last change | 20110908 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class CL_SMT_REF_CONTAINER has no forward declaration.
Interfaces
Class CL_SMT_REF_CONTAINER has no interface implemented.
Friends
Class CL_SMT_REF_CONTAINER has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Private | Type reference (TYPE) | SMT_APPLICATION | Mapping | 20080606 | |||
| 2 | Instance attribute | Private | Type reference (TYPE) | SMT_EVENT | Mapping Step | 20080606 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Enrich Error Message in Case of Incorrect Parameter Transfer | 20080606 | |
| 2 | Instance method | Public | Method | Set Application and Event | 20080606 | |
| 3 | Instance method | Public | Method | Set References | 20080104 | |
| 4 | Instance method | Public | Method | Set References of Work Variable | 20080104 |
Events
Class CL_SMT_REF_CONTAINER has no event.
Types
Class CL_SMT_REF_CONTAINER has no local type.
Method Signatures
Method ADD_MESSAGES_FOR_WRONG_PARA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_DATA | Call by reference | Type reference (TYPE) | DATA | 20080606 | ||||
| 2 | I_PROTOCOL | Call by reference | Object reference (TYPE REF TO) | CL_SMT_PROTOCOL | Protokoll | 20080606 | |||
| 3 | I_STRUCTURE_ID | Call by reference | Type reference (TYPE) | SMT_STRUCTURE_IDENTIFICATOR | Identifiziert die Struktur | 20080606 |
Method ADD_MESSAGES_FOR_WRONG_PARA on class CL_SMT_REF_CONTAINER has no exception.
Method SET_APPLICATION_AND_EVENT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_APPLICATION | Call by reference | Type reference (TYPE) | SMT_APPLICATION | Mapping | 20080606 | |||
| 2 | I_EVENT | Call by reference | Type reference (TYPE) | SMT_EVENT | Mapping Schritt | 20080606 |
Method SET_APPLICATION_AND_EVENT on class CL_SMT_REF_CONTAINER has no exception.
Method SET_REFERENCES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CH_CHANGE | Call by reference | Type reference (TYPE) | DATA | Änderungsstruktur | 20080104 | |||
| 2 | CH_TARGET | Call by reference | Type reference (TYPE) | DATA | Zielstruktur | 20080104 | |||
| 3 | I_ADD1 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 1 | 20080104 | |||
| 4 | I_ADD10 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 10 | 20080104 | |||
| 5 | I_ADD11 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 11 | 20080104 | |||
| 6 | I_ADD12 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 12 | 20080104 | |||
| 7 | I_ADD13 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 13 | 20080104 | |||
| 8 | I_ADD14 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 14 | 20080104 | |||
| 9 | I_ADD15 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 15 | 20080104 | |||
| 10 | I_ADD16 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 16 | 20080104 | |||
| 11 | I_ADD17 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 17 | 20080104 | |||
| 12 | I_ADD18 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 18 | 20080104 | |||
| 13 | I_ADD19 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 19 | 20080104 | |||
| 14 | I_ADD2 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 2 | 20080104 | |||
| 15 | I_ADD20 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 20 | 20080104 | |||
| 16 | I_ADD3 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 3 | 20080104 | |||
| 17 | I_ADD4 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 4 | 20080104 | |||
| 18 | I_ADD5 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 5 | 20080104 | |||
| 19 | I_ADD6 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 6 | 20080104 | |||
| 20 | I_ADD7 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 7 | 20080104 | |||
| 21 | I_ADD8 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 8 | 20080104 | |||
| 22 | I_ADD9 | Call by reference | Type reference (TYPE) | DATA | Zusatzstruktur 9 | 20080104 | |||
| 23 | I_PREDECESSOR1 | Call by reference | Type reference (TYPE) | DATA | 1. Vorgängerstruktur | 20080104 | |||
| 24 | I_PREDECESSOR2 | Call by reference | Type reference (TYPE) | DATA | 2. Vorgängerstruktur | 20080104 | |||
| 25 | I_PREDECESSOR3 | Call by reference | Type reference (TYPE) | DATA | 3. Vorgängerstruktur | 20080104 | |||
| 26 | I_PREDECESSOR4 | Call by reference | Type reference (TYPE) | DATA | 4. Vorgängerstruktur | 20080104 | |||
| 27 | I_SET_PARA | Call by reference | Type reference (TYPE) | SMT_SET_PARAMETER | gesetzte Parameter | 20080104 | |||
| 28 | I_SOURCE | Call by reference | Type reference (TYPE) | DATA | Quellstruktur | 20080104 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler im Customizing | 20080422 |
Method SET_WORK_REFERENCES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_TARGET_WORK_REF | Call by reference | Object reference (TYPE REF TO) | DATA | Arbeitsbereich Zielstruktur | 20080104 |
Method SET_WORK_REFERENCES on class CL_SMT_REF_CONTAINER has no exception.
History
| Last changed by/on | SAP | 20110908 |
| SAP Release Created in | 700 |