SAP ABAP Class CL_SIC_NORM_PERFORMANCE (Performance Tools)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-EIM-IQM-IC (Application Component) Information Consistency
     S_IC_NORMALIZATION_ENGINE (Package) Information Consolidation Normalization Engine
Properties
Class CL_SIC_NORM_PERFORMANCE  
Short Description Performance Tools    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package S_IC_NORMALIZATION_ENGINE   Information Consolidation Normalization Engine 
Created 20060104   SAP 
Last change 20130531   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class CL_SIC_NORM_PERFORMANCE has no forward declaration.
Interfaces
Class CL_SIC_NORM_PERFORMANCE has no interface implemented.
Friends
Class CL_SIC_NORM_PERFORMANCE has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MR_TIMER Static Attribute Private Object reference (TYPE REF TO) IF_ABAP_RUNTIME Timer Interface 20060208
2 MV_COUNTER5 Static Attribute Private Type reference (TYPE) I 20060104
3 MV_EXIT Static Attribute Private Type reference (TYPE) XFELD 'X' Checkbox 20060105
4 MV_INIT Static Attribute Private Type reference (TYPE) XFELD ' ' Checkbox 20060105
5 MV_RUNTIME Static Attribute Private Type reference (TYPE) I 20060104
6 MV_RUNTIME1_START Static Attribute Private Type reference (TYPE) I 20060104
7 MV_RUNTIME1_TOTAL Static Attribute Private Type reference (TYPE) I 20060104
8 MV_RUNTIME2_START Static Attribute Private Type reference (TYPE) I 20060104
9 MV_RUNTIME2_TOTAL Static Attribute Private Type reference (TYPE) I 20060104
10 MV_RUNTIME3_START Static Attribute Private Type reference (TYPE) I 20060104
11 MV_RUNTIME3_TOTAL Static Attribute Private Type reference (TYPE) I 20060104
12 MV_RUNTIME4_START Static Attribute Private Type reference (TYPE) I 20060104
13 MV_RUNTIME4_TOTAL Static Attribute Private Type reference (TYPE) I 20060104
14 MV_RUNTIME5_START Static Attribute Private Type reference (TYPE) I 20060104
15 MV_RUNTIME5_TOTAL Static Attribute Private Type reference (TYPE) I 20060104
16 MV_RUNTIME_0 Static Attribute Private Type reference (TYPE) I 20060104
Methods
# Method Level Visibility Method type Description Created on
1 INITIALIZE Static method Public Method Initialize Measurement 20060104
2 READ_RUNTIME_1 Static method Public Method Read Runtime Data 20060104
3 READ_RUNTIME_2 Static method Public Method Read Runtime Data 20060104
4 READ_RUNTIME_3 Static method Public Method Read Runtime Data 20060104
5 READ_RUNTIME_4 Static method Public Method Read Runtime Data 20060104
6 READ_RUNTIME_5 Static method Public Method Read Runtime Data 20060104
7 START_1 Static method Public Method Set runtime 20060104
8 START_2 Static method Public Method Set runtime 20060104
9 START_3 Static method Public Method Set runtime 20060104
10 START_4 Static method Public Method Set runtime 20060104
11 START_5 Static method Public Method Set runtime 20060104
12 STOP_1 Static method Public Method Set runtime 20060104
13 STOP_2 Static method Public Method Set runtime 20060104
14 STOP_3 Static method Public Method Set runtime 20060104
15 STOP_4 Static method Public Method Set runtime 20060104
16 STOP_5 Static method Public Method Set runtime 20060104
Events
Class CL_SIC_NORM_PERFORMANCE has no event.
Types
Class CL_SIC_NORM_PERFORMANCE has no local type.
Method Signatures

Method INITIALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_UNAME Call by reference Type reference (TYPE) SY-UNAME User Names 20060105

Method INITIALIZE on class CL_SIC_NORM_PERFORMANCE has no exception.

Method READ_RUNTIME_1 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RUNTIME Call by reference Type reference (TYPE) I 20060104
2 Exporting EV_RUNTIME_TOTAL Call by reference Type reference (TYPE) I 20060104

Method READ_RUNTIME_1 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method READ_RUNTIME_2 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RUNTIME Call by reference Type reference (TYPE) I 20060104
2 Exporting EV_RUNTIME_TOTAL Call by reference Type reference (TYPE) I 20060104

Method READ_RUNTIME_2 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method READ_RUNTIME_3 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RUNTIME Call by reference Type reference (TYPE) I 20060104
2 Exporting EV_RUNTIME_TOTAL Call by reference Type reference (TYPE) I 20060104

Method READ_RUNTIME_3 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method READ_RUNTIME_4 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_RUNTIME Call by reference Type reference (TYPE) I 20060104
2 Exporting EV_RUNTIME_TOTAL Call by reference Type reference (TYPE) I 20060104

Method READ_RUNTIME_4 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method READ_RUNTIME_5 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_COUNTER Call by reference Type reference (TYPE) I 20060104
2 Exporting EV_RUNTIME Call by reference Type reference (TYPE) I 20060104
3 Exporting EV_RUNTIME_TOTAL Call by reference Type reference (TYPE) I 20060104

Method READ_RUNTIME_5 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method START_1 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_RESET Call by reference Type reference (TYPE) XFELD Checkbox 20060104

Method START_1 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method START_2 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_RESET Call by reference Type reference (TYPE) XFELD Checkbox 20060104

Method START_2 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method START_3 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_RESET Call by reference Type reference (TYPE) XFELD Checkbox 20060104

Method START_3 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method START_4 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_RESET Call by reference Type reference (TYPE) XFELD Checkbox 20060104

Method START_4 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method START_5 Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_RESET Call by reference Type reference (TYPE) XFELD Checkbox 20060104

Method START_5 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method STOP_1 Signature

Method STOP_1 on class CL_SIC_NORM_PERFORMANCE has no parameter.
Method STOP_1 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method STOP_2 Signature

Method STOP_2 on class CL_SIC_NORM_PERFORMANCE has no parameter.
Method STOP_2 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method STOP_3 Signature

Method STOP_3 on class CL_SIC_NORM_PERFORMANCE has no parameter.
Method STOP_3 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method STOP_4 Signature

Method STOP_4 on class CL_SIC_NORM_PERFORMANCE has no parameter.
Method STOP_4 on class CL_SIC_NORM_PERFORMANCE has no exception.

Method STOP_5 Signature

Method STOP_5 on class CL_SIC_NORM_PERFORMANCE has no parameter.
Method STOP_5 on class CL_SIC_NORM_PERFORMANCE has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 710