SAP ABAP Class CL_SCV_MEASUREMENT (Measurement)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-DWB-TOO-COV (Application Component) Coverage Analyzer
     SCOV_API_ALL (Package) Coverage API for All Purposes
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  IF_SCV_MEASUREMENT Single or Merged Coverage Measurement 20091002
Properties
Class CL_SCV_MEASUREMENT  
Short Description Measurement    
Super Class    
Instantiability of a Class 0  Private 
Final    
General Data
Message Class    
Program status     
Category 0   
Package SCOV_API_ALL   Coverage API for All Purposes 
Created 20091002   SAP 
Last change 20140121   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
# Interface Abstract Final Description Created on
1 IF_SCV_MEASUREMENT Single or Merged Coverage Measurement 20091002
Friends
Class CL_SCV_MEASUREMENT has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 ADMIN Instance attribute Private Object reference (TYPE REF TO) LIF_ADMIN 20110419
2 AUTHORITY_CHECK Static Attribute Private Object reference (TYPE REF TO) IF_SCV_AUTHORITY_CHECK 20091002
3 CALCULATOR Instance attribute Private Object reference (TYPE REF TO) IF_SCV_CALCULATOR 20100409
4 COMPONENT_EXPANDER Instance attribute Private Object reference (TYPE REF TO) CL_SCV_HIERARCHY_EXPANDER 20091002
5 CONTENT_PROVIDER Instance attribute Private Object reference (TYPE REF TO) LIF_CONTENT_PROVIDER 20100813
6 CON_STATUS_FINALIZED Instance attribute Public Attribute reference (LIKE) 20110419
7 CON_STATUS_INITIAL Instance attribute Public Attribute reference (LIKE) 20091027
8 CON_STATUS_RUNNING Instance attribute Public Attribute reference (LIKE) 20091027
9 CON_STATUS_STOPPED Instance attribute Public Attribute reference (LIKE) 20091027
10 DEFAULT_CONFIGURATION Instance attribute Private Object reference (TYPE REF TO) IF_SCV_RESULT_CONFIGURATION 20091125
11 DEFAULT_SELECTION Instance attribute Private Object reference (TYPE REF TO) IF_SCV_SELECTION 20091125
12 FINALIZE_TIME Instance attribute Private Type reference (TYPE) TIMESTAMP 20091002
13 LOCAL_SERVER_ONLY Instance attribute Private Type reference (TYPE) ABAP_BOOL 20091002
14 NAME Instance attribute Private Type reference (TYPE) CVA_MEASUREMENT_NAME 20091002
15 PACKAGE_EXPANDER Instance attribute Private Object reference (TYPE REF TO) CL_SCV_HIERARCHY_EXPANDER 20091002
16 RESULT_DATA_REPOSITORY Instance attribute Private Object reference (TYPE REF TO) IF_SCV_RD_REPOSITORY 20101126
17 SERIES Instance attribute Private Object reference (TYPE REF TO) IF_SCV_SERIES Test Series 20091124
18 START_TIME Instance attribute Private Type reference (TYPE) TIMESTAMP 20091002
19 STATUS Instance attribute Private Type reference (TYPE) CVA_MEASUREMENT_STATUS CON_STATUS_INITIAL 20091002
20 STOP_TIME Instance attribute Private Type reference (TYPE) TIMESTAMP 20091002
21 TESTGROUP Instance attribute Private Object reference (TYPE REF TO) IF_SCV_TESTGROUP 20091002
22 TESTKEY_EXPIRATION Instance attribute Private Object reference (TYPE REF TO) CL_SCV_EXPIRATION 20091002
23 TYPE Instance attribute Private Type reference (TYPE) CVA_MEASUREMENT_TYPE 20091002
24 USED_CONFIGURATION Instance attribute Private Object reference (TYPE REF TO) IF_SCV_RESULT_CONFIGURATION 20091125
25 USED_SELECTION Instance attribute Private Object reference (TYPE REF TO) IF_SCV_SELECTION 20091125
26 USERS Instance attribute Private Type reference (TYPE) IF_SCV_MEASUREMENT=>USERS 20091002
Methods
# Method Level Visibility Method type Description Created on
1 ADD_RESULT Instance method Private Method Appends a results node beneath another 20091002
2 ATTACH_SUBPACKAGES Instance method Private Method Inserts the related subpackages 20091002
3 BUILD_COMPONENT_NODE Instance method Private Method Determines the results nodes for a component 20091002
4 BUILD_FILTERED_SELECTION_NODE Instance method Private Method 20130712
5 BUILD_PACKAGE_NODE Instance method Private Method Determines results node for a package 20091002
6 BUILD_PROGRAM_NODE Instance method Private Method Determines results node for a program 20091002
7 BUILD_SELECTION_NODE Instance method Private Method Determines results node for a selection 20091002
8 BUILD_SELECTION_RESULT Instance method Private Method 20100805
9 CLASS_CONSTRUCTOR Static method Public Constructor CLASS_CONSTRUCTOR 20091008
10 CREATE Static method Public Method Creates a new single measurement 20091002
11 CREATE_DEFAULT_EXPIRATION Static method Private Method Creates a standard expiry date (7 days) 20091014
12 CREATE_FROM_TESTKEY Static method Public Method Reconstructs a measurement from test keys 20091102
13 DERIVE_PROGRAMS Instance method Private Method Determines program objects for the package 20091002
14 FILL_COMPONENT Instance method Private Method Fills a component 20091002
15 FILL_PACKAGE Instance method Private Method Fills a package with its program nodes 20091002
16 FILTER_BY_EXCL_PACKAGE_RANGE Instance method Private Method Filters packages to be excluded 20091002
17 FINALIZE Instance method Public Method Finalizes a measurement (without authorization check) 20091002
18 GET_DEMO Static method Public Method Creates a simulated measurement 20091002
19 GET_STATUS Instance method Public Method 20091027
20 GET_TESTGROUP_DUMMY Static method Public Method Returns the implementation for a finalized test group 20091002
21 INIT Instance method Private Method Initializes the measurement 20091002
22 INITIALIZE_COVERAGE Instance method Private Method Creates empty coverage objects for a results node 20091002
23 IS_MAIN_SWITCH_ON Instance method Private Method Checks whether the Coverage Analyzer is activated (system) 20091002
24 IS_SERVER_SWITCH_ON Instance method Private Method Checks whether Coverage Analyzer is activated (server) 20091002
25 MERGE_MEASUREMENTS Static method Public Method Merges single measurements 20091008
26 RAISE_EXCEPTION_IF_NOT_STOPPED Instance method Private Method Registers User Error if Measurement Cannot Be Evaluated 20100805
27 RECONSTITUTE Static method Public Method Restores a measurement 20091002
28 RECONSTITUTE_RESULT Instance method Public Method Restores a result 20091002
29 REPLACE_ADMIN Instance method Private Method 20110419
30 REPLACE_AUTHORITY_CHECK Instance method Public Method For Dependency Injection 20091002
31 REPLACE_CALCULATOR Instance method Public Method For Dependency Injection 20100412
32 REPLACE_COMPONENT_ACCESSOR Instance method Public Method For Dependency Injection 20091002
33 REPLACE_CONTENT_PROVIDER Instance method Private Method For Dependency Injection 20100813
34 REPLACE_PACKAGE_ACCESSOR Instance method Public Method For Dependency Injection 20091002
35 REPLACE_RAWDATA_REPOSITORY Instance method Private Method For Dependency Injection 20100618
36 RESOLVE_COMPS_TO_PACK_EXCLUDES Instance method Private Method Determines packages to exclude 20091002
37 SET_SERIES Instance method Public Method Sets a Test Series 20091125
38 SET_USERS Instance method Public Method Sets the users who measurements are taken for 20091002
39 START Instance method Public Method Starts a measurement (without authorization check) 20091002
40 STOP Instance method Public Method Stops a measurement (without authorization check) 20091002
Events
# Event Type Visibility Description Created on
1 STATUS_CHANGED Instance Event
(0)
Public
(2)
20091027
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 TY_PACKAGE Private Type reference (TYPE) STRING 20091002
2 TY_PACKAGE_HIERARCHY Private See coding 20091002 ty_package_hierarchy TYPE SORTED TABLE OF ty_package_hierarchy_line
3 TY_PACKAGE_HIERARCHY_LINE Private See coding 20091002 BEGIN OF ty_package_hierarchy_line, child TYPE ty_package, parent TYPE ty_package, END OF ty_package_hierarchy_line
Method Signatures

Method ADD_RESULT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CHILD Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
2 Importing I_PARENT Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002

Method ADD_RESULT on class CL_SCV_MEASUREMENT has no exception.

Method ATTACH_SUBPACKAGES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE_HIERARCHY Call by reference Type reference (TYPE) TY_PACKAGE_HIERARCHY 20091002
2 Importing I_PARENT_NAME Call by reference Type reference (TYPE) TY_PACKAGE 20091002
3 Importing I_PARENT_NODE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method BUILD_COMPONENT_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_COMPONENT_NAME Call by reference Type reference (TYPE) CSEQUENCE 20091002
2 Returning R_COMPONENT_NODE Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20091013
2 CX_SCV_EXECUTION_ERROR 20091002

Method BUILD_FILTERED_SELECTION_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EVALUATION_CONSTRAINTS Call by reference Object reference (TYPE REF TO) CL_SCV_EVALUATION_CONSTRAINTS 20130718
2 Importing I_PROGRAMS Call by reference Type reference (TYPE) IF_SCV_RD_REPOSITORY=>TY_PROGRAMS 20130712
3 Importing I_RESULT_NAME Call by reference Type reference (TYPE) CVA_RESULT_NAME 20130719
4 Returning R_FILTERED_SELECTION_NODE Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20130712
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20130712

Method BUILD_PACKAGE_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE_NAME Call by reference Type reference (TYPE) CSEQUENCE 20091002
2 Returning R_PACKAGE_NODE Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20091013
2 CX_SCV_EXECUTION_ERROR 20091002

Method BUILD_PROGRAM_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EVALUATION_CONSTRAINTS Call by reference Object reference (TYPE REF TO) CL_SCV_EVALUATION_CONSTRAINTS 20130718
2 Importing I_PROGRAM_NAME Call by reference Type reference (TYPE) PROGNAME 20091002
3 Importing I_SUPPRESS_CALL_ERRORS Call by reference Type reference (TYPE) ABAP_BOOL 20100426
4 Returning R_PROGRAM_NODE Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20091013
2 CX_SCV_EXECUTION_ERROR 20091002

Method BUILD_SELECTION_NODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_NAME Call by reference Type reference (TYPE) CVA_RESULT_NAME 20100618
2 Importing I_SELECTION Call by reference Object reference (TYPE REF TO) IF_SCV_SELECTION 20091002
3 Returning R_SELECTION_NODE Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method BUILD_SELECTION_RESULT Signature

Method BUILD_SELECTION_RESULT on class CL_SCV_MEASUREMENT has no parameter.
Method BUILD_SELECTION_RESULT on class CL_SCV_MEASUREMENT has no exception.

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_SCV_MEASUREMENT has no parameter.
Method CLASS_CONSTRUCTOR on class CL_SCV_MEASUREMENT has no exception.

Method CREATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LOCAL_SERVER_ONLY Call by reference Type reference (TYPE) ABAP_BOOL 20091002
2 Importing I_NAME Call by reference Type reference (TYPE) CVA_MEASUREMENT_NAME 20091002
3 Importing I_SERIES Call by reference Object reference (TYPE REF TO) IF_SCV_SERIES Messreihe 20091124
4 Importing I_TESTKEY_EXPIRATION Call by reference Object reference (TYPE REF TO) CL_SCV_EXPIRATION 20091002
5 Returning R_MEASUREMENT Value transfer Object reference (TYPE REF TO) CL_SCV_MEASUREMENT 20091002

Method CREATE on class CL_SCV_MEASUREMENT has no exception.

Method CREATE_DEFAULT_EXPIRATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_EXPIRATION Value transfer Object reference (TYPE REF TO) CL_SCV_EXPIRATION 20091014

Method CREATE_DEFAULT_EXPIRATION on class CL_SCV_MEASUREMENT has no exception.

Method CREATE_FROM_TESTKEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_TESTKEY Call by reference Type reference (TYPE) CVA_TESTK Testgruppe 20091102
2 Returning R_MEASUREMENT Value transfer Object reference (TYPE REF TO) CL_SCV_MEASUREMENT Einzelne oder kombinierte Abdeckungsmessung 20091102
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR Statische Exceptions der SCV API 20091103

Method DERIVE_PROGRAMS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE Knoten eines Messergebnisses 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method FILL_COMPONENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_COMPONENT Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method FILL_PACKAGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method FILTER_BY_EXCL_PACKAGE_RANGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE_RANGE Value transfer Type reference (TYPE) IF_SCV_SELECTION=>TY_PACKAGE_RANGE 20091002
2 Importing I_PROGRAM_ENTRIES Call by reference Type reference (TYPE) LIF_CONTENT_PROVIDER=>TY_PROGRAM_ENTRIES 20091002
3 Importing I_SELECTION_NODE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method FINALIZE Signature

Method FINALIZE on class CL_SCV_MEASUREMENT has no parameter.
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20091026
2 CX_SCV_EXECUTION_ERROR 20091002

Method GET_DEMO Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AUTHORITY_CHECK Call by reference Object reference (TYPE REF TO) IF_SCV_AUTHORITY_CHECK Berechtigungsprüfung 20091002
2 Importing I_COV_ANALYZER_SWITCHED_ON Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE 20110419
3 Importing I_LOCAL_SERVER_SWITCHED_ON Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE 20110419
4 Importing I_START_TIME Call by reference Type reference (TYPE) TIMESTAMP UTC-Zeitstempel in Kurzform (JJJJMMTThhmmss) 20091202
5 Importing I_STATUS Call by reference Type reference (TYPE) CVA_MEASUREMENT_STATUS IF_SCV_MEASUREMENT=>CON_STATUS_STOPPED Status in dem sich die Messung befinden soll 20091002
6 Importing I_TESTGROUP Call by reference Object reference (TYPE REF TO) IF_SCV_TESTGROUP 20110419
7 Importing I_USERS Call by reference Type reference (TYPE) IF_SCV_MEASUREMENT=>USERS Benutzer für die gemessen wird 20091002
8 Returning R_MEASUREMENT Value transfer Object reference (TYPE REF TO) IF_SCV_MEASUREMENT Messung die auf Test Doubles zurückgreift 20091002

Method GET_DEMO on class CL_SCV_MEASUREMENT has no exception.

Method GET_STATUS Signature

Method GET_STATUS on class CL_SCV_MEASUREMENT has no parameter.
Method GET_STATUS on class CL_SCV_MEASUREMENT has no exception.

Method GET_TESTGROUP_DUMMY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_TESTGROUP Value transfer Object reference (TYPE REF TO) IF_SCV_TESTGROUP Testgruppe 20091002

Method GET_TESTGROUP_DUMMY on class CL_SCV_MEASUREMENT has no exception.

Method INIT Signature

Method INIT on class CL_SCV_MEASUREMENT has no parameter.
Method INIT on class CL_SCV_MEASUREMENT has no exception.

Method INITIALIZE_COVERAGE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_RESULT_NODE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002

Method INITIALIZE_COVERAGE on class CL_SCV_MEASUREMENT has no exception.

Method IS_MAIN_SWITCH_ON Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_ON Value transfer Type reference (TYPE) ABAP_BOOL 20091002

Method IS_MAIN_SWITCH_ON on class CL_SCV_MEASUREMENT has no exception.

Method IS_SERVER_SWITCH_ON Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_SERVER_NAME Call by reference Type reference (TYPE) MSNAME2 20091002
2 Returning R_ON Value transfer Type reference (TYPE) ABAP_BOOL 20091002

Method IS_SERVER_SWITCH_ON on class CL_SCV_MEASUREMENT has no exception.

Method MERGE_MEASUREMENTS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EXPIRATION Call by reference Object reference (TYPE REF TO) CL_SCV_EXPIRATION Haltbarkeitsdatum 20091008
2 Importing I_MEASUREMENTS Call by reference Type reference (TYPE) IF_SCV_MEASUREMENT=>TAB Zu kombinierende Messungen 20091008
3 Importing I_NAME Call by reference Type reference (TYPE) CVA_MEASUREMENT_NAME Name der kombinierten Messung 20091008
4 Importing I_STRATEGY Call by reference Object reference (TYPE REF TO) CE_SCV_MERGE_STRATEGY CE_SCV_MERGE_STRATEGY=>UNION Aufzählungstyp für Strategien zum Kombinieren von Messungen 20091008
5 Returning R_MERGED_MEASUREMENT Value transfer Object reference (TYPE REF TO) IF_SCV_MEASUREMENT Kombinierte Messung 20091008
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR Aufruffehler 20091008
2 CX_SCV_EXECUTION_ERROR Statische Exceptions der SCV API 20091008

Method RAISE_EXCEPTION_IF_NOT_STOPPED Signature

Method RAISE_EXCEPTION_IF_NOT_STOPPED on class CL_SCV_MEASUREMENT has no parameter.
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20100805

Method RECONSTITUTE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LOCAL_SERVER_ONLY Call by reference Type reference (TYPE) ABAP_BOOL ABAP_TRUE 20091002
2 Importing I_NAME Call by reference Type reference (TYPE) CVA_MEASUREMENT_NAME 20091002
3 Importing I_SERIES Call by reference Object reference (TYPE REF TO) IF_SCV_SERIES Messreihe 20091124
4 Importing I_START_TIME Call by reference Type reference (TYPE) TIMESTAMP 20091002
5 Importing I_STATUS Call by reference Type reference (TYPE) CVA_MEASUREMENT_STATUS 20091002
6 Importing I_STOP_TIME Call by reference Type reference (TYPE) TIMESTAMP 20091002
7 Importing I_TESTGROUP Call by reference Object reference (TYPE REF TO) IF_SCV_TESTGROUP 20091002
8 Importing I_TYPE Call by reference Type reference (TYPE) CVA_MEASUREMENT_TYPE IF_SCV_MEASUREMENT=>CON_TYPE_SINGLE 20091002
9 Returning R_MEASUREMENT Value transfer Object reference (TYPE REF TO) CL_SCV_MEASUREMENT 20091002

Method RECONSTITUTE on class CL_SCV_MEASUREMENT has no exception.

Method RECONSTITUTE_RESULT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CONFIGURATION Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_CONFIGURATION Ermöglicht die Feinkonfiguration des Ergebnisbaums 20091126
2 Importing I_NAME Call by reference Type reference (TYPE) CVA_RESULT_NAME 20091002
3 Importing I_ROOT_NODE Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_NODE 20091002
4 Importing I_SELECTION Call by reference Object reference (TYPE REF TO) IF_SCV_SELECTION 20091002
5 Returning R_RESULT Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT 20091002

Method RECONSTITUTE_RESULT on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_ADMIN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADMIN Call by reference Object reference (TYPE REF TO) LIF_ADMIN 20110419

Method REPLACE_ADMIN on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_AUTHORITY_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AUTHORITY_CHECK Call by reference Object reference (TYPE REF TO) IF_SCV_AUTHORITY_CHECK 20091002

Method REPLACE_AUTHORITY_CHECK on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_CALCULATOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CALCULATOR Call by reference Object reference (TYPE REF TO) IF_SCV_CALCULATOR Abdeckungsberechner 20100412

Method REPLACE_CALCULATOR on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_COMPONENT_ACCESSOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_COMPONENT_ACCESSOR Call by reference Object reference (TYPE REF TO) IF_SCV_ELEMENT_ACCESSOR 20091002

Method REPLACE_COMPONENT_ACCESSOR on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_CONTENT_PROVIDER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PROVIDER Call by reference Object reference (TYPE REF TO) LIF_CONTENT_PROVIDER 20100813

Method REPLACE_CONTENT_PROVIDER on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_PACKAGE_ACCESSOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_PACKAGE_ACCESSOR Call by reference Object reference (TYPE REF TO) IF_SCV_ELEMENT_ACCESSOR 20091002

Method REPLACE_PACKAGE_ACCESSOR on class CL_SCV_MEASUREMENT has no exception.

Method REPLACE_RAWDATA_REPOSITORY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_RAWDATA_REPOSITORY Call by reference Object reference (TYPE REF TO) IF_SCV_RD_REPOSITORY Liefert Abdeckungsrohdaten von Programmen 20100618

Method REPLACE_RAWDATA_REPOSITORY on class CL_SCV_MEASUREMENT has no exception.

Method RESOLVE_COMPS_TO_PACK_EXCLUDES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_IGNORE_HIERARCHY Call by reference Type reference (TYPE) ABAP_BOOL 20091002
2 Importing I_SELECTION Call by reference Object reference (TYPE REF TO) IF_SCV_SELECTION 20091002
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002

Method SET_SERIES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_SERIES Call by reference Object reference (TYPE REF TO) IF_SCV_SERIES Messreihe 20091125

Method SET_SERIES on class CL_SCV_MEASUREMENT has no exception.

Method SET_USERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_ADD_SYUNAME_IF_EMPTY Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE 20100806
2 Importing I_USERS Call by reference Type reference (TYPE) IF_SCV_MEASUREMENT=>USERS 20091002

Method SET_USERS on class CL_SCV_MEASUREMENT has no exception.

Method START Signature

Method START on class CL_SCV_MEASUREMENT has no parameter.
# Exception Resumable Description Created on
1 CX_SCV_CALL_ERROR 20110419
2 CX_SCV_EXECUTION_ERROR 20091002

Method STOP Signature

Method STOP on class CL_SCV_MEASUREMENT has no parameter.
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR 20091002
Event Signatures

Event STATUS_CHANGED Signature
Event STATUS_CHANGED on class CL_SCV_MEASUREMENT has no parameter.
History
Last changed by/on SAP  20140121 
SAP Release Created in 800